Notifier HS-NCM-W High-Speed Network Communication Module, Wire
Connects Notifier panels, NCA and NCA-2 annunciators and the DVC to High-Speed NOTI-FIRE-NET over twisted-pair wire, with up to 2 node addresses.

Dealer for NotifierA standalone embedded gateway with IP capability that lets ONYX Series users monitor several sites over Ethernet without remote workstations.
Standards and approvals: UL/ULC Standards and NFPA 72 Fire Alarm Systems, UL / ULC: S5697, CSFM: 7300-1525:103, MEA: 286-07-E
| Specification | Details |
|---|---|
| PC version | • Requires an ONYXworks® Workstation (see ONYXworks® data sheet DN-7048). • Operating temperature: 0°C to 49°C (32°F to 120°F). |
| Embedded version | • Input current: 450 mA @ 24 VDC. • Input voltage range: 19 VDC to 29 VDC. • Operating temperature: 0°C to 49°C (32°F to 120°F). • Mounts on a CHS-4L chassis in a CAB-4 Series cabinet (see data sheet DN-6857). • Direct connection to NFS2-640, NFS-640, NFS-320, NFS2-3030, and NFS-3030 fire alarm control panels. |
Specifications as published by Notifier. Please confirm the exact model with us before ordering.
Connects Notifier panels, NCA and NCA-2 annunciators and the DVC to High-Speed NOTI-FIRE-NET over twisted-pair wire, with up to 2 node addresses.
Connects Notifier panels, annunciators and the DVC to High-Speed NOTI-FIRE-NET over multi-mode fibre-optic cable.
Connects Notifier panels, annunciators and the DVC to High-Speed NOTI-FIRE-NET over single-mode fibre-optic cable.
Joins twisted-pair wire and multi-mode fibre-optic segments on the same High-Speed NOTI-FIRE-NET network.
Joins twisted-pair wire and single-mode fibre-optic segments on the same High-Speed NOTI-FIRE-NET network.
Joins multi-mode and single-mode fibre-optic segments on the same High-Speed NOTI-FIRE-NET network.
A remote indicator wired to a fire detector that is concealed or hard to see, so the source of an alarm can be found quickly. It works with conventional or addressable detectors.
A gateway that links fire alarm panels, the cloud and peripherals, reading the panel's inventory data and passing it to licensed cloud software for remote monitoring and management.
The card that connects DXc panels into a network. One is fitted to each panel, on the four studs at the left-hand side of the control panel.
An RS232 kit for DXc panels that connects a serial device, such as a BMS or AMX fire graphics software, through a third party protocol.
A menu driven hand-held tool for System Sensor Series 300 conventional detectors, giving access to detector functions and logs.
A surface mounting enclosure for System Sensor addressable input and output modules. The base is fixed to the wall, then the module and cover are screwed on with the two screws supplied.