Siemens FDAI93 Cerberus PRO Remote Alarm Indicator, Flush Mounted
A transparent flush indicator lamp connected in parallel to automatic fire detectors, made to fit into door frames, switching panels, ceiling voids or special housings.

Dealer for SiemensA wall mounted alarm indicator connected in parallel to automatic fire detectors that are not easy to see, which lights as soon as a connected detector alarms.
Standards and approvals: DNV, MED, UKCA
| Specification | FDAI92 |
|---|---|
| Protection category | IP40 |
| Operating voltage | DC 5…8 V |
| Operating temperature | -25…80 °C |
| Operating current | 35 mA |
| Relative humidity | ≤95 % rel. |
| Cable capacity | Max. 1,5 mm2 |
| Ex-classification | Ex ib IIC T6 (Ta ≤ 55 °C) Ex ib IIC T5 (Ta ≤ 70 °C) |
| Dimensions (W x H x D) | 85 x 85 x 28 mm |
| Color | Pure white, ~RAL 9010 |
| Number of addresses | 0 |
Specifications as published by Siemens. Please confirm the exact model with us before ordering.
A transparent flush indicator lamp connected in parallel to automatic fire detectors, made to fit into door frames, switching panels, ceiling voids or special housings.
An addressable alarm indicator that sits on the FDnet or C-NET loop and can be programmed to show the source of an alarm from detectors that are hard to see.
A universal tester for installed FDnet and C-NET fire detection lines when no control unit is connected yet, for electricians, installers and service technicians.
An advanced line tester for Siemens Sinteso, Cerberus PRO and Cerberus FIT systems that works with the Building X Fire Install app.
A handheld tool for inserting, removing, testing and commissioning Sinteso, Sinteso Nova and Cerberus Nova detectors and call points.
A remote indicator wired to a fire detector that is concealed or hard to see, so the source of an alarm can be found quickly. It works with conventional or addressable detectors.
A gateway that links fire alarm panels, the cloud and peripherals, reading the panel's inventory data and passing it to licensed cloud software for remote monitoring and management.
Connects Notifier panels, NCA and NCA-2 annunciators and the DVC to High-Speed NOTI-FIRE-NET over twisted-pair wire, with up to 2 node addresses.
Connects Notifier panels, annunciators and the DVC to High-Speed NOTI-FIRE-NET over multi-mode fibre-optic cable.
The card that connects DXc panels into a network. One is fitted to each panel, on the four studs at the left-hand side of the control panel.
An RS232 kit for DXc panels that connects a serial device, such as a BMS or AMX fire graphics software, through a third party protocol.