Karam FFP1 SL NR D Respirator with Nose Padding and Adjustable Headband
Karam logoSupplier for Karam

Karam FFP1 SL NR D Respirator with Nose Padding and Adjustable Headband

FFP1 SL NR DEN 149:2001+A1:2009IS 9473:2002With or without valve

An FFP1 respirator for solid and liquid particles with a cushioned nose pad and a headband adjuster, with or without an exhalation valve (RFH11 and RFH11+). Karam states it to EN 149:2001+A1:2009 and it is ISI marked to IS 9473:2002.

  • FFP1 SL NR D: solid and liquid particles, single shift, dolomite dust tested
  • Breathable non-woven polypropylene fabric with sweat-absorbent inner layer
  • Cushioned nose padding helps the seal
  • Adjustable headband; exhalation valve on RFH11+
  • Karam states up to 12 hours of use

Standards and approvals: EN 149:2001+A1:2009, ISI 9473:2002, CE, ISI, CDSCO, IS 9473:2002

Ask price & availability

Download the official Karam catalogue (PDF, 63.0 MB)

Specifications

Specifications
SpecificationCO2 Content of Inhalation Air (Clause 5.7 of IS 9473:2002 and EN 149:2001+A1:2009) RFH11CO2 Content of Inhalation Air (Clause 5.7 of IS 9473:2002 and EN 149:2001+A1:2009) RFH11+Breathing Resistance (Clause 5.11 of IS 9473:2002 and EN 149:2001+A1:2009) RFH11Breathing Resistance (Clause 5.11 of IS 9473:2002 and EN 149:2001+A1:2009) RFH11+Particulate Filtering Efficiency (Clause 5.4.2 of IS 9473:2002 and EN 149:2001+A1:2009) RFH11Tota L Inward Leakage (Clause 5.4.1 of IS 9473:2002 and EN 149:2001+A1:2009) RFH11Particulate Filtering Efficiency (Clause 5.4.2 of IS 9473:2002 and EN 149:2001+A1:2009) RFH11+Tota L Inward Leakage (Clause 5.4.1 of IS 9473:2002 and EN 149:2001+A1:2009) RFH11+Flammability (Clause 5.6 of IS 9473:2002 and EN 149:2001+A1:2009) RFH11Flammability (Clause 5.6 of IS 9473:2002 and EN 149:2001+A1:2009) RFH11+Bacteria L Filtering Efficiency RFH11Bacteria L Filtering Efficiency RFH11+
Vital TestCO2 Content of Inhalation Air (Clause 5.7 of IS 9473:2002 and EN 149:2001+A1:2009)CO2 Content of Inhalation Air (Clause 5.7 of IS 9473:2002 and EN 149:2001+A1:2009)Breathing Resistance (Clause 5.11 of IS 9473:2002 and EN 149:2001+A1:2009)Breathing Resistance (Clause 5.11 of IS 9473:2002 and EN 149:2001+A1:2009)Particulate Filtering Efficiency (Clause 5.4.2 of IS 9473:2002 and EN 149:2001+A1:2009)Total Inward Leakage (Clause 5.4.1 of IS 9473:2002 and EN 149:2001+A1:2009)Particulate Filtering Efficiency (Clause 5.4.2 of IS 9473:2002 and EN 149:2001+A1:2009)Total Inward Leakage (Clause 5.4.1 of IS 9473:2002 and EN 149:2001+A1:2009)Flammability (Clause 5.6 of IS 9473:2002 and EN 149:2001+A1:2009)Flammability (Clause 5.6 of IS 9473:2002 and EN 149:2001+A1:2009)Bacterial Filtering EfficiencyBacterial Filtering Efficiency
Requirement as per StandardCarbon dioxide content of the inhalation air (dead space) should not exceed an average of 1% (by vol.)Carbon dioxide content of the inhalation air (dead space) should not exceed an average of 1% (by vol.)Inhalation Flow- 30 l/min: Should be less than 0.6 mbar Inhalation Flow- 95 l/min: Should be less than 2.1 mbar Exhalation Flow- 160 l/min: Should be less than 3.0 mbarInhalation Flow- 30 l/min: Should be less than 0.6 mbar Inhalation Flow- 95 l/min: Should be less than 2.1 mbar Exhalation Flow- 160 l/min: Should be less than 3.0 mbarRequirement as per standard- 80%The arithmetic mean of the total inward leakage of at least 8 out of 10 subjects should not be greater than 22% The arithmetic mean of the total inward leakage of at least 46 subjects should not be greater than 25%Requirement as per standard- 80%The arithmetic mean of the total inward leakage of at least 8 out of 10 subjects should not be greater than 22% The arithmetic mean of the total inward leakage of at least 46 subjects should not be greater than 25%The face mask when subject to pass the flame once at the specified speed should not continue to burn after removal of flameThe face mask when subject to pass the flame once at the specified speed should not continue to burn after removal of flameBacterial filtering efficiency should be >90%Bacterial filtering efficiency should be >90%
KARAM Respirator< 0.5%< 0.4%0.3 mbar 1.5 mbar 1.9 mbar0.4 mbar 1.2 mbar 1.2 mbarExceeds 90%2.44% 7.08%Exceeds 90%2.78% 3.58%KARAM Respirator does not continue to burn after removal of flameKARAM Respirator does not continue to burn after removal of flame> 99%> 90%

Specifications as published by Karam. Please confirm the exact model with us before ordering.

More Karam Respiratory Protection

Respirators and Dust Masks from other brands

Delta Plus

Delta Plus M9200 ROTOR GALAXY Full Face Mask

EN 136 Class 3EN 148-1 threadSilicone

A silicone full face mask with the patented ROTOR adjustment, which tightens with one hand even in gloves, a wide 210° polycarbonate screen and an inner half mask that reduces misting. It is stated to EN 136 Class 3 and takes EN 148-1 threaded M9000 cartridges, sold separately.

View specifications ›
Delta Plus

Delta Plus M9300 STRAP GALAXY Full Face Mask

EN 136 Class 3EN 148-1 threadStrap harness

A silicone full face mask with silicone strap adjustment, a 210° polycarbonate screen, an inner half mask and a shoulder strap to carry it when not in use. Stated to EN 136 Class 3, it takes EN 148-1 threaded M9000 cartridges, sold separately.

View specifications ›

See all respirators and dust masks ›