FFP2 SL NR DEN 149:2001+A1:2009IS 9473:2002With or without valve

The FFP2 version of Karam's padded headband respirator, for solid and liquid particles, with or without an exhalation valve (RFH12 and RFH12+). Stated to EN 149:2001+A1:2009 and ISI marked to IS 9473:2002.

  • FFP2 SL NR D class; the standard's requirement is listed as 94%
  • Contoured nose padding for a closer seal
  • Headband with length adjuster
  • Non-woven polypropylene with sweat-absorbent interior and water-repellent outer layer
  • Exhalation valve on RFH12+ to cut heat build-up

Standards and approvals: EN 149:2001+A1:2009, ISI 9473:2002, CE, ISI, CDSCO, IS 9473:2002

Ask price & availability

Download the official Karam catalogue (PDF, 63.0 MB)

Specifications

Specifications
SpecificationCO2 Content of Inhalation Air (Clause 5.7 of IS 9473:2002 and EN 149:2001+A1:2009) RFH12CO2 Content of Inhalation Air (Clause 5.7 of IS 9473:2002 and EN 149:2001+A1:2009) RFH12+Breathing Resistance (Clause 5.11 of IS 9473:2002 and EN 149:2001+A1:2009) RFH12Breathing Resistance (Clause 5.11 of IS 9473:2002 and EN 149:2001+A1:2009) RFH12+Particulate Filtering Efficiency (Clause 5.4.2 of IS 9473:2002 and EN 149:2001+A1:2009) RFH12Tota L Inward Leakage (Clause 5.4.1 of IS 9473:2002 and EN 149:2001+A1:2009) RFH12Particulate Filtering Efficiency (Clause 5.4.2 of IS 9473:2002 and EN 149:2001+A1:2009) RFH12+Tota L Inward Leakage (Clause 5.4.1 of IS 9473:2002 and EN 149:2001+A1:2009) RFH12+Flammability (Clause 5.6 of IS 9473:2002 and EN 149:2001+A1:2009) RFH12Flammability (Clause 5.6 of IS 9473:2002 and EN 149:2001+A1:2009) RFH12+Bacteria L Filtering Efficiency RFH12Bacteria L Filtering Efficiency RFH12+
Vital TestCO2 Content of Inhalation Air (Clause 5.7 of IS 9473:2002 and EN 149:2001+A1:2009)CO2 Content of Inhalation Air (Clause 5.7 of IS 9473:2002 and EN 149:2001+A1:2009)Breathing Resistance (Clause 5.11 of IS 9473:2002 and EN 149:2001+A1:2009)Breathing Resistance (Clause 5.11 of IS 9473:2002 and EN 149:2001+A1:2009)Particulate Filtering Efficiency (Clause 5.4.2 of IS 9473:2002 and EN 149:2001+A1:2009)Total Inward Leakage (Clause 5.4.1 of IS 9473:2002 and EN 149:2001+A1:2009)Particulate Filtering Efficiency (Clause 5.4.2 of IS 9473:2002 and EN 149:2001+A1:2009)Total Inward Leakage (Clause 5.4.1 of IS 9473:2002 and EN 149:2001+A1:2009)Flammability (Clause 5.6 of IS 9473:2002 and EN 149:2001+A1:2009)Flammability (Clause 5.6 of IS 9473:2002 and EN 149:2001+A1:2009)Bacterial Filtering EfficiencyBacterial Filtering Efficiency
Requirement as per StandardCarbon dioxide content of the inhalation air (dead space) should not exceed an average of 1% (by vol.)Carbon dioxide content of the inhalation air (dead space) should not exceed an average of 1% (by vol.)Inhalation Flow- 30 l/min: Should be less than 0.7 mbar Inhalation Flow- 95 l/min: Should be less than 2.4 mbar Exhalation Flow- 160 l/min: Should be less than 3.0 mbarInhalation Flow- 30 l/min: Should be less than 0.7 mbar Inhalation Flow- 95 l/min: Should be less than 2.4 mbar Exhalation Flow- 160 l/min: Should be less than 3.0 mbarRequirement as per standard- 94%The arithmetic mean of the total inward leakage of at least 8 out of 10 subjects should not be greater than 8% The arithmetic mean of the total inward leakage of at least 46 subjects should not be greater than 11%Requirement as per standard- 94%The arithmetic mean of the total inward leakage of at least 8 out of 10 subjects should not be greater than 8% The arithmetic mean of the total inward leakage of at least 46 subjects should not be greater than 11%The face mask when subject to pass the flame once at the specified speed should not continue to burn after removal of flameThe face mask when subject to pass the flame once at the specified speed should not continue to burn after removal of flameBacterial filtering efficiency should be >90%Bacterial filtering efficiency should be >90%
KARAM Respirator< 0.6%< 0.5%0.3 mbar 1.5 mbar 1.8 mbar0.3 mbar 1.4 mbar 1.2 mbarExceeds 97%2.04% 6.31%Exceeds 97%2.76% 3.28%KARAM Respirator does not continue to burn after removal of flameKARAM Respirator does not continue to burn after removal of flame> 99%> 99%

Specifications as published by Karam. Please confirm the exact model with us before ordering.

More Karam Respiratory Protection

Respirators and Dust Masks from other brands

Delta Plus

Delta Plus M9200 ROTOR GALAXY Full Face Mask

EN 136 Class 3EN 148-1 threadSilicone

A silicone full face mask with the patented ROTOR adjustment, which tightens with one hand even in gloves, a wide 210° polycarbonate screen and an inner half mask that reduces misting. It is stated to EN 136 Class 3 and takes EN 148-1 threaded M9000 cartridges, sold separately.

View specifications ›
Delta Plus

Delta Plus M9300 STRAP GALAXY Full Face Mask

EN 136 Class 3EN 148-1 threadStrap harness

A silicone full face mask with silicone strap adjustment, a 210° polycarbonate screen, an inner half mask and a shoulder strap to carry it when not in use. Stated to EN 136 Class 3, it takes EN 148-1 threaded M9000 cartridges, sold separately.

View specifications ›

See all respirators and dust masks ›

Ask price
Call +91 92440 89060Send a text messageEmail usWhatsApp us