ISO 9001:2015 Certified · MSME Registered · Military Engineering Services Registered
Fire Protection System logoFIRE PROTECTION SYSTEMTMFire safety contractors, dealers & distributors · Bhopal, M.P.
EXCELLENCE IN FIRE EXTINGUISHER, FIRE HYDRANT, FIRE ALARM & FIRE SUPPRESSION SYSTEMS
Karam FFP1S Disposable Respirator, Ear Loop or Headband
Karam logoSupplier for Karam

Karam FFP1S Disposable Respirator, Ear Loop or Headband

FFP1SIS 9473:2002ISI markedWith or without valveEar loop or headband

Karam's FFP1S dust respirator in five fittings: ear loops (RF01) or headbands (RFH01), each with or without an exhalation valve, and a headband version with adjuster (RFH10). ISI marked to IS 9473:2002 under licence CM/L-8300137209.

  • FFP1 class for solid particles; the standard's requirement is listed as 80%
  • Multi-layer filter, with an electrostatic filter layer listed on the headband versions
  • Water-repellent outer layer and sweat-absorbent inner layer
  • Exhalation valve on RF01+ and RFH01+ for easier breathing out
  • Karam states up to 12 hours of cumulative use

Standards and approvals: ISI 9473:2002, ISI, CDSCO, IS 9473:2002

Ask price & availability

Download the official Karam catalogue (PDF, 63.0 MB)

Specifications

Specifications
SpecificationCO2 Content of Inhalation Air (Clause 5.7 of IS 9473:2002) RF01CO2 Content of Inhalation Air (Clause 5.7 of IS 9473:2002) RF01+CO2 Content of Inhalation Air (Clause 5.7 of IS 9473:2002) RFH01CO2 Content of Inhalation Air (Clause 5.7 of IS 9473:2002) RFH01+CO2 Content of Inhalation Air (Clause 5.7 of IS 9473:2002) RFH10Breathing Resistance (Clause 5.11 of IS 9473:2002) RF01Breathing Resistance (Clause 5.11 of IS 9473:2002) RF01+Breathing Resistance (Clause 5.11 of IS 9473:2002) RFH01Breathing Resistance (Clause 5.11 of IS 9473:2002) RFH01+Breathing Resistance (Clause 5.11 of IS 9473:2002) RFH10Particulate Filtering Efficiency (Clause 5.4.2 of IS 9473:2002) RF01Tota L Inward Leakage (Clause 5.4.1 of IS 9473:2002) RF01Particulate Filtering Efficiency (Clause 5.4.2 of IS 9473:2002) RF01+Tota L Inward Leakage (Clause 5.4.1 of IS 9473:2002) RF01+Particulate Filtering Efficiency (Clause 5.4.2 of IS 9473:2002) RFH01Tota L Inward Leakage (Clause 5.4.1 of IS 9473:2002) RFH01Particulate Filtering Efficiency (Clause 5.4.2 of IS 9473:2002) RFH01+Tota L Inward Leakage (Clause 5.4.1 of IS 9473:2002) RFH01+Particulate Filtering Efficiency (Clause 5.4.2 of IS 9473:2002) RFH10Tota L Inward Leakage (Clause 5.4.1 of IS 9473:2002) RFH10Flammability (Clause 5.6 of IS 9473:2002) RF01Flammability (Clause 5.6 of IS 9473:2002) RF01+Flammability (Clause 5.6 of IS 9473:2002) RFH01Flammability (Clause 5.6 of IS 9473:2002) RFH01+Flammability (Clause 5.6 of IS 9473:2002) RFH10Bacteria L Filtering Efficiency RF01Bacteria L Filtering Efficiency RF01+Bacteria L Filtering Efficiency RFH01Bacteria L Filtering Efficiency RFH01+Bacteria L Filtering Efficiency RFH10
Vital TestCO2 Content of Inhalation Air (Clause 5.7 of IS 9473:2002)CO2 Content of Inhalation Air (Clause 5.7 of IS 9473:2002)CO2 Content of Inhalation Air (Clause 5.7 of IS 9473:2002)CO2 Content of Inhalation Air (Clause 5.7 of IS 9473:2002)CO2 Content of Inhalation Air (Clause 5.7 of IS 9473:2002)Breathing Resistance (Clause 5.11 of IS 9473:2002)Breathing Resistance (Clause 5.11 of IS 9473:2002)Breathing Resistance (Clause 5.11 of IS 9473:2002)Breathing Resistance (Clause 5.11 of IS 9473:2002)Breathing Resistance (Clause 5.11 of IS 9473:2002)Particulate Filtering Efficiency (Clause 5.4.2 of IS 9473:2002)Total Inward Leakage (Clause 5.4.1 of IS 9473:2002)Particulate Filtering Efficiency (Clause 5.4.2 of IS 9473:2002)Total Inward Leakage (Clause 5.4.1 of IS 9473:2002)Particulate Filtering Efficiency (Clause 5.4.2 of IS 9473:2002)Total Inward Leakage (Clause 5.4.1 of IS 9473:2002)Particulate Filtering Efficiency (Clause 5.4.2 of IS 9473:2002)Total Inward Leakage (Clause 5.4.1 of IS 9473:2002)Particulate Filtering Efficiency (Clause 5.4.2 of IS 9473:2002)Total Inward Leakage (Clause 5.4.1 of IS 9473:2002)Flammability (Clause 5.6 of IS 9473:2002)Flammability (Clause 5.6 of IS 9473:2002)Flammability (Clause 5.6 of IS 9473:2002)Flammability (Clause 5.6 of IS 9473:2002)Flammability (Clause 5.6 of IS 9473:2002)Bacterial Filtering EfficiencyBacterial Filtering EfficiencyBacterial Filtering EfficiencyBacterial Filtering EfficiencyBacterial Filtering Efficiency
Requirement as per StandardCarbon dioxide content of the inhalation air (dead space) should not exceed an average of 1% (by vol.)Carbon dioxide content of the inhalation air (dead space) should not exceed an average of 1% (by vol.)Carbon dioxide content of the inhalation air (dead space) should not exceed an average of 1% (by vol.)Carbon dioxide content of the inhalation air (dead space) should not exceed an average of 1% (by vol.)Carbon dioxide content of the inhalation air (dead space) should not exceed an average of 1% (by vol.)Inhalation Flow- 30 l/min: Should be less than 0.6 mbar Inhalation Flow- 95 l/min: Should be less than 2.1 mbar Exhalation Flow- 160 l/min: Should be less than 3.0 mbarInhalation Flow- 30 l/min: Should be less than 0.6 mbar Inhalation Flow- 95 l/min: Should be less than 2.1 mbar Exhalation Flow- 160 l/min: Should be less than 3.0 mbarInhalation Flow- 30 l/min: Should be less than 0.6 mbar Inhalation Flow- 95 l/min: Should be less than 2.1 mbar Exhalation Flow- 160 l/min: Should be less than 3.0 mbarInhalation Flow- 30 l/min: Should be less than 0.6 mbar Inhalation Flow- 95 l/min: Should be less than 2.1 mbar Exhalation Flow- 160 l/min: Should be less than 3.0 mbarInhalation Flow- 30 l/min: Should be less than 0.6 mbar Inhalation Flow- 95 l/min: Should be less than 2.1 mbar Exhalation Flow- 160 l/min: Should be less than 3.0 mbarRequirement as per standard- 80%The arithmetic mean of the total inward leakage of at least 8 out of 10 subjects should not be greater than 22% The arithmetic mean of the total inward leakage of at least 46 subjects should not be greater than 25%Requirement as per standard- 80%The arithmetic mean of the total inward leakage of at least 8 out of 10 subjects should not be greater than 22% The arithmetic mean of the total inward leakage of at least 46 subjects should not be greater than 25%Requirement as per standard- 80%The arithmetic mean of the total inward leakage of at least 8 out of 10 subjects should not be greater than 22% The arithmetic mean of the total inward leakage of at least 46 subjects should not be greater than 25%Requirement as per standard- 80%The arithmetic mean of the total inward leakage of at least 8 out of 10 subjects should not be greater than 22% The arithmetic mean of the total inward leakage of at least 46 subjects should not be greater than 25%Requirement as per standard- 80%The arithmetic mean of the total inward leakage of at least 8 out of 10 subjects should not be greater than 22% The arithmetic mean of the total inward leakage of at least 46 subjects should not be greater than 25%The face mask when subject to pass the flame once at the specified speed should not continue to burn after removal of flameThe face mask when subject to pass the flame once at the specified speed should not continue to burn after removal of flameThe face mask when subject to pass the flame once at the specified speed should not continue to burn after removal of flameThe face mask when subject to pass the flame once at the specified speed should not continue to burn after removal of flameThe face mask when subject to pass the flame once at the specified speed should not continue to burn after removal of flameBacterial filtering efficiency should be >90%Bacterial filtering efficiency should be >90%Bacterial filtering efficiency should be >90%Bacterial filtering efficiency should be >90%Bacterial filtering efficiency should be >90%
KARAM Respirator< 0.5%< 0.4%< 0.5%< 0.4%< 0.5%0.4 mbar 1.7 mbar 2.4 mbar0.3 mbar 1.4 mbar 1.2 mbar0.3 mbar 1.5 mbar 1.9 mbar0.4 mbar 1.2 mbar 1.2 mbar0.3 mbar 1.5 mbar 1.9 mbarExceeds 90%3.36% 9.36%Exceeds 90%2.89% 6.58%Exceeds 90%2.44% 7.08%Exceeds 90%2.78% 3.58%Exceeds 90%2.44% 7.08%KARAM Respirator does not continue to burn after removal of flameKARAM Respirator does not continue to burn after removal of flameKARAM Respirator does not continue to burn after removal of flameKARAM Respirator does not continue to burn after removal of flameKARAM Respirator does not continue to burn after removal of flame> 90%> 90%> 90%> 90%> 90%

Specifications as published by Karam. Please confirm the exact model with us before ordering.

More Karam Respiratory Protection

Respirators and Dust Masks from other brands

Delta Plus

Delta Plus M9200 ROTOR GALAXY Full Face Mask

EN 136 Class 3EN 148-1 threadSilicone

A silicone full face mask with the patented ROTOR adjustment, which tightens with one hand even in gloves, a wide 210° polycarbonate screen and an inner half mask that reduces misting. It is stated to EN 136 Class 3 and takes EN 148-1 threaded M9000 cartridges, sold separately.

View specifications ›
Delta Plus

Delta Plus M9300 STRAP GALAXY Full Face Mask

EN 136 Class 3EN 148-1 threadStrap harness

A silicone full face mask with silicone strap adjustment, a 210° polycarbonate screen, an inner half mask and a shoulder strap to carry it when not in use. Stated to EN 136 Class 3, it takes EN 148-1 threaded M9000 cartridges, sold separately.

View specifications ›

See all respirators and dust masks ›

Ask price
Call +91 92440 89060Send a text messageEmail usWhatsApp us