Honeywell X-618 X-DA4125EN Class-D Amplifier, 4 x 125 W
A four channel Class-D amplifier for the X-618 system with fully digital audio transmission, which keeps the signal free from interference and easy to control. It takes a 24 V DC backup supply.

A 500 W Class-D power amplifier that provides 70 V or 100 V audio amplification for the Intevio PAVA system, with dual channel audio capability.
Standards and approvals: CE
| Specification | HAM-2000 |
|---|---|
| Frequency Response | 80Hz~18KHz (+1dB ~ - 3dB) |
| Main Power Supply Voltage | ~220V-240V 50/60Hz |
| Rated Power | 500W |
| Gross Weight | 13.2Kg |
| Backup power supply | ~220V-240V 50/60Hz |
| Main Power Supply Fuse | T10AH 250V |
| Humidity | < 95%, without condensing |
| Operating Temperature | -10°C~+55°C(14°F to +131°F) |
| Storage Temperature | -40°C~+70°C(-40°F to +158°F) |
| Product dimensions (W×H×D) | 482 mm×88 mm ×407 mm |
| Package dimension (W×H×D) | 580 mm×235 mm×552mm |
| Net Weight | 10.6Kg |
| Power consumption | <720W |
| Amplifier Output | 70V / 100V |
| Input impedance | 20KΩ |
| Input Sensitivity(RJ-45) | 1.4V |
| Aux, Input 1 | 1.4V |
| Aux, Input 2 | 100V |
| Audio cascade Output | 1.4V |
| SNR | >100 dB, A weighted |
| Non-linear distortion | <0.1% (at 1/3 rated power, 1kHz |
| Indicator Lights | Power, main power fault, backup power fault, protection and signal level indicator. |
| Cooling method | Air cooling |
| Indicator lights | Power, main power fault, backup power fault, protection and signal level indicator. |
| Description | Amplifier |
Specifications as published by Honeywell. Please confirm the exact model with us before ordering.
A four channel Class-D amplifier for the X-618 system with fully digital audio transmission, which keeps the signal free from interference and easy to control. It takes a 24 V DC backup supply.
A single channel 500 W Class-D amplifier for the X-618 system with fully digital audio transmission, which keeps the signal free from interference and easy to control. It takes a 24 V DC backup supply.
A two channel Class-D amplifier for the X-618 system with fully digital audio transmission, which keeps the signal free from interference and easy to control. It takes a 24 V DC backup supply.
Amplifies the audio for high power loudspeakers on the X-618 PAVA system, with balanced and unbalanced inputs and automatic detection of power supply errors.
A four channel amplifier for the X-618 digital PAVA system, with a built-in fuse for over-current protection and a cooling fan to keep it running efficiently.
A 500 W Class-D amplifier for the X-618 PAVA system that detects power supply errors and protects itself against overheating, over-current, overvoltage and under-voltage.
The heart of the Notifier audio command centre, giving voice evacuation for emergency communications and mass notification, with 8 simultaneous messages and networking across a campus or large facility.
A distribution board that adds digital bulk audio evacuation to the DVC system, converting digital audio to analogue and routing it to amplifiers and optional backups.
Microprocessor based fire alarm panel with a built-in PA system, a 100 V RMS output and up to 11 minutes of digital voice recording. Alert and evacuation announcements are sent through a PA zone selector with All Call.
Sizes: 2,4,8,16,32,64 Zone
Microprocessor based master station for fire fighter telephone systems, available in 2 to 64 zones and working on a DTMF, PSTN based, 2 wire, 24 V telephone circuit. Soft-Chip states it is compatible with all conventional and addressable fire fighter telephone systems.
The control panel of the FYRLAAST fire fighter telephone system. Specifications are confirmed on enquiry.
An addressable extension telephone for the FYRLAAST fire fighter telephone system. Specifications are confirmed on enquiry.
Try "landing valve", "Apollo call point", "9 kg ABC" or a model code.
No products yet. Tap "Add to quote" on any product, then send the whole list to us in one WhatsApp message.