Notifier ACPS-610(E) Addressable Charger Power Supply
An auxiliary power supply with a battery charging option, giving 6 amps of shared power to four outputs while charging batteries, or 10 amps with an external charger.

Dealer for NotifierAn addressable power supply and battery charger with up to three 24 VDC outputs, for the NFS-3030 and NFS2-3030 panels, that can also be the primary supply for the NCA-2 annunciator.
Standards and approvals: UL: S635, ULC: CS118, City of Chicago, City of Denver, MEA: 345-02-E, CSFM: 7165-0028:224, FM: Approved, FDNY: #6026
| Specification | Details |
|---|---|
| AMPS24 | 110-120 VAC 50/60 Hz input, 5 A maximum; |
| AMPS24E | 220-240 VAC 50/60 Hz input, 2.5 A maximum. |
| Secondary power (battery) charging circuit | Current-limited, sealed lead-acid battery charger which will charge 7 to 200 AH batteries. |
| Selectable charging current | 1.0 A, 2.0 A or 5.0 A. |
| Wire sizes | 10 AWG (5.26 mm²) to 22 AWG (0.326 mm²). |
| Battery fuse (F2) | 15 A, fast-acting. |
| Shipping Weight | 4.25 lb |
Specifications as published by Notifier. Please confirm the exact model with us before ordering.
An auxiliary power supply with a battery charging option, giving 6 amps of shared power to four outputs while charging batteries, or 10 amps with an external charger.
An addressable power supply for INSPIRE N16 panels with four power-limited NAC outputs, two 24 VDC auxiliary outputs and a remote sync input.
A plug-in loop control module that adds signalling line circuits to ONYX NFS2-640 and NFS2-3030 fire alarm control panels.
A loop expander module listed together with the LCM-320, with FDNY certificates for use with the NFS2-640 and NFS2-3030 panels.
A remote indicator wired to a fire detector that is concealed or hard to see, so the source of an alarm can be found quickly. It works with conventional or addressable detectors.
A gateway that links fire alarm panels, the cloud and peripherals, reading the panel's inventory data and passing it to licensed cloud software for remote monitoring and management.
The card that connects DXc panels into a network. One is fitted to each panel, on the four studs at the left-hand side of the control panel.
An RS232 kit for DXc panels that connects a serial device, such as a BMS or AMX fire graphics software, through a third party protocol.
A menu driven hand-held tool for System Sensor Series 300 conventional detectors, giving access to detector functions and logs.
A surface mounting enclosure for System Sensor addressable input and output modules. The base is fixed to the wall, then the module and cover are screwed on with the two screws supplied.
Try "landing valve", "Apollo call point", "9 kg ABC" or a model code.
No products yet. Tap "Add to quote" on any product, then send the whole list to us in one WhatsApp message.