Ravel Carbon Monoxide (CO) Gas Detector with Relay Output
A conventional 4 wire detector for carbon monoxide that runs on 24 V DC and signals the panel through a normally open alarm relay.

Dealer for RavelA conventional 4 wire detector for natural gas (methane) that alarms at or below 0.25 LEL and signals the panel through a normally open alarm relay.
| Specification | RE-386NG |
|---|---|
| Operating Voltage | (21 ~ 27)VDC |
| Start-up current | ≤120mA |
| Start-up time | ≤10min |
| Quiescent Current | 45 mA |
| Alarm Current (max) | 60 mA |
| Sampling Time | 3 s ~ 5 s |
| Reset Voltage | ≤1 V |
| Reset Time | ≤5 s |
| Alarm response threshold | ≤ 0.25 LELCH4 |
Specifications as published by Ravel. Please confirm the exact model with us before ordering.
A conventional 4 wire detector for carbon monoxide that runs on 24 V DC and signals the panel through a normally open alarm relay.
A conventional 4 wire detector for LPG (propane) that alarms at or below 0.25 LEL and signals the panel through a normally open alarm relay.
A mains powered LPG detector with a semiconductor gas sensor, for use with addressable or conventional fire detection panels.
An aspirating smoke detector that draws air from separate sampling points through microbore tubes, so it can pinpoint the location of a fire threat. It has three sensitivity settings and an IP40 enclosure.
A very early warning aspirating smoke detector for small, business-critical areas of less than 500 m2 (5,380 sq ft). It samples air continuously through a pipe network and detects very small amounts of smoke with light scattering.
An aspirating smoke detector with a built-in SLC module that communicates directly with Notifier panels over the SLC loop, offered in one-pipe and four-pipe models (VEP-A00-1P-NTF-VN, VEP-A00-P-NTF-VN and VEP-A10-P-NTF-VN).
An aspirating smoke detector with sector addressability for up to four sectors and a built-in SLC module for direct connection to Notifier panels (VES-A00-P-NTF-VN and VES-A10-P-NTF-VN).
An addressable reflector-type linear beam smoke detector that works on infra red light obscuration, for large open spaces such as warehouses and atriums. The combined transmitter and receiver connects directly to an analogue loop.
An intelligent reflector-type beam smoke detector that uses IR video imaging, for spacious rooms, open areas and high ceilings, with only one device to install and align.
Try "landing valve", "Apollo call point", "9 kg ABC" or a model code.
No products yet. Tap "Add to quote" on any product, then send the whole list to us in one WhatsApp message.