Tyco Series TY-B Standard Response Intermediate Level Upright and Pendent Sprinklers, K5.6 (TFP352)
Tyco logoSupplier for Tyco

Tyco Series TY-B Standard Response Intermediate Level Upright and Pendent Sprinklers, K5.6 (TFP352)

Intermediate levelIn-rack5 mm glass bulbK5.6TFP352

K5.6, 5 mm glass bulb standard response intermediate level sprinklers for rack storage and open gridded catwalks, shielded from the spray of higher sprinklers.

  • K-factor 5.6 gpm/psi½ (80.6 Lpm/bar½)
  • Maximum working pressure 175 psi (12.1 bar), or 250 psi (17.2 bar) under the UL listing
  • Temperature ratings printed in the data sheet: 57°C, 68°C, 79°C, 93°C, 141°C and 182°C
  • Sprinkler details in TFP152 and guard and shield details in TFP780
  • Tyco lists UL and C-UL listing and FM approval

Standards and approvals: UL and C-UL Listed, FM Approved

Ask price & availability

Download the official Tyco catalogue (PDF, 4.6 MB)

Specifications

Specifications
SpecificationUpright 5.6K, 1/2 in. NPTPendent 5.6K, 1/2 in. NPTK=5.6 gpm/psi½ (80,6 Lpm/bar½) Temperature Ratings See Table A Finishes
SINTY315TY325
SIN entry as printedUpright 5.6K, 1/2 in. NPTPendent 5.6K, 1/2 in. NPT
OrientationUprightPendent
K-factor5.6K5.6K
Thread1/2 in. NPT1/2 in. NPT
ResponseStandard ResponseStandard Response
Discharge CoefficientK=5.6 gpm/psi½ (80,6 Lpm/bar½) Temperature Ratings See Table A FinishesK=5.6 gpm/psi½ (80,6 Lpm/bar½) Temperature Ratings See Table A Finishes
Maximum Working Pressure175 psi (12,1 bar) 250 psi (17,2 bar)* * The Maximum Working Pressure of 250 psi (17,2 bar) only applies to the listing by Underwriters Laboratory.175 psi (12,1 bar) 250 psi (17,2 bar)* * The Maximum Working Pressure of 250 psi (17,2 bar) only applies to the listing by Underwriters Laboratory.
FrameBronze
ButtonBrass/Copper
Sealing AssemblyStainless Steel w/TEFLON
BulbGlass
Compression ScrewBronze
DeflectorCopper
G1 and G1/S1 GuardPainted or Plated Steel
S2 ShieldPlated Steel

Specifications as published by Tyco. Please confirm the exact model with us before ordering.

More Tyco ESFR and Storage Sprinklers

Fire Sprinklers from other brands

Savemax

Savemax Flexible Drop for Sprinklers (700 to 1800 mm)

Flexible dropSprinkler connector700 to 1800 mm

A flexible hose connector that links the rigid sprinkler branch pipe above a false ceiling to the sprinkler head below it. It takes up building movement, ceiling deflection and installation misalignment, so the head can be positioned without cutting or re-routing pipe.

View specifications ›