Pendent Sprinklers (Pendant Sprinkler Heads) in Bhopal

A pendent sprinkler hangs down from the pipe and sprays water in a circle below it, which makes it the head used under most false ceilings in offices, hotels, hospitals and shops. This page compares 79 pendent models from Tyco, Savemax, HD Fire, Kartar Valves, New Age and Balaji Fire Safety: standard and quick response heads, recessed and concealed heads, extended coverage, ESFR storage, dry and residential heads.

Also called
pendant sprinkler, pendent type sprinkler, pendent sprinkler head, down facing sprinkler, ceiling sprinkler
Used for
False ceilings in offices, hotels, hospitals, schools, shops, malls and basements
Brands
Tyco, Savemax, HD Fire, Kartar Valves, New Age, Balaji Fire Safety
Supplied by
Fire Protection System, Bhopal (supplier for Tyco and New Age; authorised distributor for Savemax and Kartar Valves; dealer for HD Fire and Balaji Fire Safety), across Madhya Pradesh
Price
On request: WhatsApp or call +91 92440 89060

Which one do you need?

Office, hotel or hospital ceilingStandard and quick response
A ceiling that must look cleanConcealed sprinklers
Fewer heads in a large roomExtended coverage
High racked warehouseESFR and storage
Cold store or freezerDry pendent
Flats, hostels and homesResidential pendent

What a pendent sprinkler is

A pendent head screws into a drop from the pipe above the ceiling, with only the head and its deflector showing below. The deflector at the bottom faces down and breaks the water into a round, umbrella shaped spray over the floor. Heads are usually finished with an escutcheon plate, or recessed into a cup so less of the head shows.

Most pendent heads open with a glass bulb that breaks at its rated temperature, 68°C (red) as standard. Quick response heads use a thinner 3 mm bulb and open sooner, which is why they go in offices, hotels and hospitals; standard response heads use a 5 mm bulb.

The K factor says how much water a head gives at a given pressure. K 5.6 (K80 in metric) is the common light hazard head, while K 8.0 (K115) and larger heads give more water for ordinary hazard rooms and storage. A pendent head must only be fitted facing down, because its deflector is shaped for that position.

  • Offices and IT parks
  • Hotel rooms and corridors
  • Hospitals and clinics
  • Shops and malls
  • Basements and car parks
  • Warehouses and cold stores

Standard and quick response pendent sprinklers

The everyday pendent head for false ceilings. HD Fire and New Age heads are UL Listed, several HD Fire heads also FM Approved, Kartar K908.I and Savemax heads are ISI marked, and Tyco TY-B, TY-FRB, TY-L and TY-FRL heads carry UL, FM and LPCB approvals as listed, in K 4.2 to K 8.0.

ModelKey facts
Tyco Series TY-L Standard Response Upright, Pendent and Recessed Pendent Sprinklers, K5.6 and K8.0 (TFP110)Standard response, Solder type, K5.6 and K8.0, UL, C-UL, FM
Tyco Series TY-FRL Quick Response Upright and Pendent Sprinklers, K8.0 (TFP130)Quick response, Solder type, K8.0, UL, C-UL, FM, LPCB
Tyco Series TY-B Standard Response Upright, Pendent and Recessed Pendent Sprinklers, K5.6 and K8.0 (TFP151)Standard response, 5 mm glass bulb, K5.6 and K8.0, UL, C-UL, FM, LPCB, VdS
Tyco Series TY-B Standard Response Upright (TY315) and Pendent (TY325) Sprinklers, K5.6 (TFP152)Standard response, 5 mm glass bulb, K5.6, UL, C-UL, FM, LPCB
Tyco Series TY-FRB Quick Response Upright, Pendent and Recessed Pendent Sprinklers, K4.2, K5.6 and K8.0 (TFP171)Quick response, 3 mm glass bulb, K4.2 to K8.0, UL, C-UL, FM, LPCB, VdS
Tyco Series TY-FRB Quick Response Upright (TY313) and Pendent (TY323) Sprinklers, K5.6 (TFP172)Quick response, 3 mm glass bulb, K5.6, UL, C-UL, FM, LPCB
Tyco Model TY3201 Quick Response Pendent Sprinkler, K80 (TFP179)Pendent, Quick response, 3 mm glass bulb, K80
Tyco Series TY-B and TY-FRB 10 mm Orifice Upright, Pendent and Recessed Pendent Sprinklers, ISO 7-R 3/8 (TFP670)10 mm orifice, ISO 7-R 3/8 thread, Standard and quick response, LPCB, VdS
Tyco Series TY-B Special Response Upright and Pendent Sprinklers, K57, K80 and K115 (TFP672)Special response, 4 mm glass bulb, K57, K80, K115, VdS Approved
Savemax ISI Marked Sprinklers, Pendant, Upright and SidewallSprinkler, Pendant, upright, sidewall, 68°C bulb, IS 15105
HD Fire Pendent Sprinkler, K 5.6, UL Listed and FM ApprovedPendent, K 5.6, Light, ordinary and extra hazard, UL Listed and FM Approved
HD Fire Pendent and Upright Sprinkler, K 11.2, UL ListedPendent or upright, K 11.2, ¾ inch, UL Listed
HD Fire Pendent, Upright and Recessed Sprinkler, K 8, UL ListedPendent, upright or recessed, K 8, ¾ inch, UL Listed
HD Fire Recessed Pendent Sprinkler with Escutcheon, UL Listed and FM ApprovedRecessed pendent, Escutcheon plate, False ceilings, UL Listed and FM Approved
Kartar Valves Forged Brass Sprinkler, 15 mm, 68°C, Pendent, Upright and SidewallForged brass, 15 mm screwed, 68°C, 175 psi
New Age Pendent Sprinkler, Quick Response, UL ListedUL Listed, Pendent, Quick response, Bronze
New Age Pendent Sprinkler, Standard Response, UL ListedUL Listed, Pendent, Standard response, Bronze
Balaji Fire Safety Pendent Sprinkler, Brass, 68°CPendent, Brass, 68°C, ½ inch
Balaji Fire Safety Pendent Sprinkler, Zinc, 68°CPendent, Zinc, 68°C, ½ inch NPT

Concealed pendent sprinklers

A cover plate hides the head flush with the ceiling and drops away in a fire. The concealed sprinkler page compares every concealed model, including extended coverage, sidewall and residential heads.

ModelKey facts
Tyco Series RFII Royal Flush II Concealed Pendent Sprinkler, K5.6, Quick and Standard Response (TFP181)Concealed pendent, K5.6, 3 mm or 5 mm bulb, UL, C-UL, FM, LPCB, VdS
Tyco Series RFII-MRI Non-Magnetic Concealed Pendent Sprinkler, K5.6 (TFP182)Non-magnetic, MRI rooms, Concealed pendent, K5.6
Tyco ILLUSION Extra Large Orifice Concealed Pendent Sprinkler, K11.2 (TFP184)Concealed pendent, K11.2, Solder type, UL, C-UL
HD Fire Concealed Pendent Sprinkler, K 5.6, UL ListedConcealed pendent, K 5.6, Standard or quick response, UL Listed

Concealed sprinklers ›

Extended coverage pendent sprinklers

Extended coverage heads throw water further, so each covers a larger area and fewer heads are needed: Tyco EC-5 and EC-8 for light hazard, EC-11 and EC-14 for light and ordinary hazard, EC-8C and RFII-C for corridors, and concealed versions of several.

ESFR and storage pendent sprinklers

For warehouses with high racked or piled storage. ESFR (early suppression, fast response) heads from K14.0 to K33.6 are made to put a fire out in the rack rather than only control it, and for listed goods and heights they avoid in-rack sprinklers. Storage and intermediate level heads protect racks from above and within.

ModelKey facts
Tyco Model ESFR-25 Early Suppression Fast Response Pendent Sprinkler, K25.2 (TFP312)ESFR, Pendent, K25.2, UL, C-UL, FM, VdS, LPCB, CE
Tyco Model ESFR-17 Early Suppression Fast Response Pendent Sprinkler, K16.8, FM, VdS and LPCB (TFP315)ESFR, Pendent, K16.8, FM, VdS, LPCB, CE
Tyco Model ESFR-17 Early Suppression Fast Response Pendent Sprinkler, K16.8, 74°C and 100°C (TFP317)ESFR, Pendent, K16.8, UL, C-UL, FM, VdS, CE
Tyco Model ESFR-1 Early Suppression Fast Response Pendent Sprinkler, K14.0 (TFP318)ESFR, Pendent, K14.0, UL, C-UL, FM, VdS, LPCB, CE
Tyco Model ESFR-14 Early Suppression Fast Response Pendent Sprinkler, K14.0 (TFP319)ESFR, Pendent, K14.0, UL, C-UL, FM, CE
Tyco Model ESFR-22 Early Suppression Fast Response Pendent Sprinkler, K22.4 (TFP321)ESFR, Pendent, K22.4, UL, C-UL, FM, VdS, LPCB, CE
Tyco Model ESFR-17 Early Suppression Fast Response Pendent Sprinkler, K16.8, 68°C and 96°C (TFP322)ESFR, Pendent, K16.8, UL, C-UL, FM, CE
Tyco Model TY720 Electronically Controlled Pendent Sprinkler, K16.8, for the EAS-1 System (TFP325)Electronic control, Pendent, K16.8, EAS-1 system
Tyco Model K17-231 Standard Response Upright and Pendent Storage Sprinklers, K16.8 (TFP332)Upright and pendent, K16.8, Standard response, UL, C-UL, FM, NYC
Tyco Model TY7258 Standard Response Pendent and Recessed Pendent Sprinkler, K16.8, Specific Use (TFP337)Pendent, K16.8, Retrofit, Specific use
Tyco Model ESFR-34 Early Suppression Fast Response Pendent Sprinkler, K33.6 (TFP338)ESFR, Pendent, K33.6, FM, CE
Tyco Series ELO-231 Standard Response Upright and Pendent Storage Sprinklers, K11.2, Solder Type (TFP340)Upright and pendent, K11.2, Solder type, UL, C-UL, FM
Tyco Series ELO-231B Standard Response Upright and Pendent Storage Sprinklers, K11.2, Glass Bulb (TFP342)Upright and pendent, K11.2, Standard response, UL, C-UL, FM, VdS
Tyco Series ELO-231FRB Quick Response Upright and Pendent Storage Sprinklers, K11.2 (TFP344)Upright and pendent, K11.2, Quick response, UL, C-UL, FM, VdS, LPCB
Tyco Series TY-L Standard Response Intermediate Level Upright and Pendent Sprinklers, K5.6 and K8.0 (TFP350)Intermediate level, In-rack, Solder type, K5.6 and K8.0
Tyco Series TY-B Standard Response Intermediate Level Upright and Pendent Sprinklers, K5.6 and K8.0 (TFP351)Intermediate level, In-rack, 5 mm glass bulb, K5.6 and K8.0
Tyco Series TY-B Standard Response Intermediate Level Upright and Pendent Sprinklers, K5.6 (TFP352)Intermediate level, In-rack, 5 mm glass bulb, K5.6
Tyco Series TY-FRL Quick Response Intermediate Level Upright and Pendent Sprinkler, K8.0 (TFP355)Intermediate level, In-rack, Quick response, K8.0
Tyco Series TY-FRB Quick Response Intermediate Level Upright and Pendent Sprinklers, K5.6 and K8.0 (TFP356)Intermediate level, In-rack, 3 mm glass bulb, K5.6 and K8.0
Tyco Series TY-FRB Quick Response Intermediate Level Upright and Pendent Sprinklers, K5.6 (TFP357)Intermediate level, In-rack, 3 mm glass bulb, K5.6

Dry pendent sprinklers

Dry-type heads have a sealed barrel so no water stands in the drop. They are used in cold stores and freezers fed from a heated area, and on dry pipe and pre-action systems. Tyco offers them from K5.6 to K25.2, including dry ESFR heads.

ModelKey facts
Tyco Model ESFR-17 Dry-Type Early Suppression Fast Response Pendent Sprinkler, K16.8 (TFP320)ESFR, Dry-type, Cold storage, K16.8
Tyco Model ESFR-25 Dry-Type Early Suppression Fast Response Pendent Sprinkler, K25.2 (TFP329)ESFR, Dry-type, Cold storage, K25.2
Tyco Series LFII Dry-Type Residential Recessed Pendent Sprinkler (TY2235), K4.9 (TFP460)Dry-type, Residential recessed pendent, K4.9, UL, C-UL
Tyco Series DS-1 Dry-Type Pendent, Upright and Horizontal Sidewall Sprinklers, K5.6, Standard Response (TFP500)Dry-type, Standard response, K5.6, UL, C-UL, FM, LPCB, VdS, CE
Tyco Series DS-8 Dry-Type Pendent and Horizontal Sidewall Sprinklers, K8.0, Standard Response (TFP503)Dry-type, Standard response, K8.0, UL, C-UL
Tyco Series DS-1 Dry-Type Pendent, Upright and Horizontal Sidewall Sprinklers, K5.6, Quick Response (TFP510)Dry-type, Quick response, K5.6, UL, C-UL, FM, LPCB, CE
Tyco Series DS-8 Dry-Type Pendent and Horizontal Sidewall Sprinklers, K8.0, Quick Response (TFP513)Dry-type, Quick response, K8.0, UL, C-UL
Tyco Series DS-C Dry-Type Concealed Pendent Sprinkler, K5.6, Standard and Quick Response (TFP515)Dry-type, Concealed pendent, K5.6, UL, C-UL
Tyco Series DS-ECC Dry-Type Concealed Pendent Sprinkler (TY3539), K5.6, Quick Response Extended Coverage (TFP518)Dry-type, Concealed pendent, QREC, K5.6
Tyco Series DS-2 Dry-Type Pendent Sprinkler, K11.2, Standard Coverage (TFP530)Dry-type, Pendent, K11.2, UL, C-UL
Tyco Series DS-2 Dry-Type Extended Coverage Pendent Sprinkler, K11.2, Light and Ordinary Hazard (TFP540)Dry-type, Pendent, Extended coverage, K11.2
Tyco Series DS-1 Stainless Steel Dry-Type Pendent and Horizontal Sidewall Sprinklers, K5.6, Standard and Quick Response (TFP560)Dry-type, Stainless steel, K5.6, UL, C-UL, LPCB, CE

Residential pendent sprinklers

Residential heads are made to keep a room survivable long enough for people to get out, for flats, hostels and homes, and are listed to NFPA 13D, 13R and 13. Tyco LFII heads come in K3.0 to K6.9.

ModelKey facts
Tyco Series LFII Residential Pendent and Recessed Pendent Sprinkler (TY2234), K4.9, Wet and Dry Pipe (TFP400)Residential pendent, K4.9, Wet and dry pipe, NFPA 13D, 13R, 13
Tyco Series LFII Residential Pendent and Recessed Pendent Sprinkler (TY3934), K5.8, Wet Pipe (TFP401)Residential pendent, K5.8, Wet pipe, UL, C-UL
Tyco Series LFII Residential Pendent Sprinkler (TY1234), K3.0, Wet Pipe (TFP402)Residential pendent, K3.0, Small rooms, UL Listed
Tyco Series LFII Residential Pendent and Recessed Pendent Sprinkler (TY2236), K4.9, Wet Pipe (TFP403)Residential pendent, K4.9, Wet pipe, UL, C-UL
Tyco Series LFII Residential Pendent, Recessed Pendent and Concealed Pendent Sprinkler (TY4234), K6.9, NFPA 13 Optimized (TFP408)Residential, K6.9, NFPA 13 optimized, UL, C-UL
Tyco Series LFII Residential Polymeric Flat Plate Concealed Pendent Sprinkler (TY1534), K3.0 (TFP439)Concealed pendent, Polymeric, K3.0, Plastic pipe
Tyco Series LFII Residential Flat Plate Concealed Pendent Sprinkler (TY2534), K4.9, Wet Pipe (TFP446)Concealed pendent, K4.9, Wet pipe, UL, C-UL
Tyco Lead-Free Series LFII Residential Polymeric Flat Plate Concealed Pendent Sprinkler (TY3534), K4.9 (TFP447)Concealed pendent, Polymeric, Lead-free, K4.9
Tyco Series LFII Residential Flat Plate Concealed Pendent Sprinkler (TY3584), K5.8, Wet Pipe (TFP448)Concealed pendent, K5.8, Wet pipe, UL, C-UL
Tyco Series LFII Residential Domed Plate Concealed Pendent Sprinkler (TY2234), K4.9, Wet and Dry Pipe (TFP450)Concealed pendent, Domed plate, K4.9, Wet and dry pipe

Special application pendent sprinklers

Institutional heads that resist tampering, for prisons and secure wards; stainless steel heads for corrosive areas; Quartzoid heads for high temperatures; flush heads for concrete ceilings; and flat spray heads.

How to choose

Check the ceiling first. A pendent head goes under a false ceiling, or on drops below an open ceiling. Where the pipes are exposed with no false ceiling, an upright head is normally used, and on a wall a sidewall head.

Then match the design: the K factor and spacing come from the hazard class and the hydraulic design, the response from the use of the room, and the temperature from the hottest the ceiling gets in normal use. Heads in one room should be of the same type and rating.

Finally choose the finish and the approval the consultant or insurer asks for: chrome or white in show areas, brass in plant rooms, UL Listed, FM Approved or ISI marked. Keep spare heads and the head wrench in a spare sprinkler cabinet.

Frequently asked questions

What is a pendent sprinkler?
A sprinkler head that hangs down from the pipe, with its deflector facing the floor, used under false ceilings. It sprays water in a round pattern below it when its bulb breaks.
Pendent or pendant: which is right?
Both spellings are used for the same head. Makers such as Tyco and HD Fire write pendent, and pendant is common in India.
What is the difference between pendent and upright sprinklers?
A pendent head hangs down from the pipe, and an upright sprinkler stands on top of the pipe and sprays up against the ceiling and down. They cannot be swapped, because each deflector is shaped for one position.
What does 68°C on a sprinkler mean?
It is the temperature at which the bulb breaks and the head opens. 68°C, a red bulb, is the standard rating; see the bulb colour chart.
What is the price of a pendent sprinkler in Bhopal?
It depends on the brand, the K factor, the response, the finish, the approval (UL, FM or ISI) and the quantity, and makers change their price lists often, so we quote each order instead of listing prices. Send the type, K factor, temperature and quantity on WhatsApp at +91 92440 89060 and we will reply with the current price. Every supply is billed on a GST invoice.