Tyco Series TY-B Standard Response Upright (TY315) and Pendent (TY325) Sprinklers, K5.6 (TFP152)
Tyco logoSupplier for Tyco

Tyco Series TY-B Standard Response Upright (TY315) and Pendent (TY325) Sprinklers, K5.6 (TFP152)

Standard response5 mm glass bulbK5.6UL, C-UL, FM, LPCBTFP152

K5.6 glass bulb standard response, standard coverage spray sprinklers with a 5 mm bulb, for light, ordinary and extra hazard commercial buildings, with a recessed pendent option for finished ceilings.

  • K-factor 5.6 gpm/psi½ (80.6 Lpm/bar½)
  • Recessed pendent with a two-piece Style 15 escutcheon (up to 5/8 in. of recessed adjustment) or Style 20 escutcheon (up to 1/2 in.)
  • Maximum working pressure 175 psi (12.1 bar), or 250 psi (17.2 bar) under the UL listing
  • Temperature ratings printed in the data sheet: 57°C, 68°C, 79°C, 93°C, 141°C and 182°C
  • Unshielded TY315 and TY325 for in-rack use under solid shelves; intermediate level versions are covered in TFP352
  • Tyco lists UL and C-UL listing and FM and LPCB approval

Standards and approvals: Listed by Underwriters Laboratories, Inc. (UL), Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL), Approved by FM Global (FM Approvals), Approved by the Loss Prevention Certification Board, Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05)

Ask price & availability

Download the official Tyco catalogue (PDF, 4.6 MB)

Specifications

Specifications
SpecificationUpright 5.6K, 1/2 in. NPTPendent 5.6K, 1/2 in. NPTK = 5.6 GPM/psi½ (80,6 LPM/bar½)
SINTY315TY325
SIN entry as printedUpright 5.6K, 1/2 in. NPTPendent 5.6K, 1/2 in. NPT
OrientationUprightPendent
K-factor5.6K5.6K
Thread1/2 in. NPT1/2 in. NPT
ResponseStandard ResponseStandard Response
Discharge CoefficientK = 5.6 GPM/psi½ (80,6 LPM/bar½)K = 5.6 GPM/psi½ (80,6 LPM/bar½)
Maximum Working Pressure175 psi (12.1 bar) 250 psi (17.2 bar)* * The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Underwriters Laboratories, Inc. (UL).175 psi (12.1 bar) 250 psi (17.2 bar)* * The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Underwriters Laboratories, Inc. (UL).
Temperature RatingsSee Table ASee Table A
FinishesSprinkler: See Table BSprinkler: See Table B
Recessed EscutcheonWhite Coated, Black Coated, Chrome Plated, or Brass Plated
FrameBronze
ButtonBrass/Copper
Sealing AssemblyStainless Steel w/TEFLON
BulbGlass
Compression ScrewBronze
DeflectorBronze

Specifications as published by Tyco. Please confirm the exact model with us before ordering.

More Tyco Standard Spray Sprinklers

Fire Sprinklers from other brands