Tyco Series TY-FRB Quick Response Upright, Pendent and Recessed Pendent Sprinklers, K4.2, K5.6 and K8.0 (TFP171)
Tyco logoSupplier for Tyco

Tyco Series TY-FRB Quick Response Upright, Pendent and Recessed Pendent Sprinklers, K4.2, K5.6 and K8.0 (TFP171)

Quick response3 mm glass bulbK4.2 to K8.0UL, C-UL, FM, LPCB, VdSTFP171

Glass bulb quick response, standard coverage spray sprinklers with a 3 mm bulb, for light or ordinary hazard buildings such as banks, hotels and shopping malls.

  • K-factor 4.2, 5.6 or 8.0 gpm/psi½ (60.5, 80.6 or 115.2 Lpm/bar½)
  • Recessed version with a two-piece Style 10 or 40 escutcheon, or a Style 20 or 30 escutcheon, in 1/2 in. or 3/4 in. NPT
  • Temperature ratings printed in the data sheet: 57°C, 68°C, 79°C, 93°C and 141°C
  • Unshielded TY3131, TY3231, TY4131 and TY4231 heads for racks with solid shelves; intermediate level versions are covered in TFP356
  • Corrosion-resistant coated versions where applicable
  • Tyco lists UL and C-UL listing and FM, LPCB and VdS approval

Standards and approvals: UL and C-UL Listed, FM, LPCB, VdS Approved

Ask price & availability

Download the official Tyco catalogue (PDF, 4.6 MB)

Specifications

Specifications
SpecificationUpright 4.2K, 1/2 in. NPTPendent 4.2K, 1/2 in. NPTUpright 5.6K, 1/2 in. NPTPendent 5.6K, 1/2 in. NPTUpright 8.0K, 3/4 in. NPTPendent 8.0K, 3/4 in. NPTUpright 8.0K, 1/2 in. NPTPendent 8.0K, 1/2 in. NPTDetailsDetails
SINTY2131TY2231TY3131TY3231TY4131TY4231TY4831TY4931
SIN entry as printedUpright 4.2K, 1/2 in. NPTPendent 4.2K, 1/2 in. NPTUpright 5.6K, 1/2 in. NPTPendent 5.6K, 1/2 in. NPTUpright 8.0K, 3/4 in. NPTPendent 8.0K, 3/4 in. NPTUpright 8.0K, 1/2 in. NPTPendent 8.0K, 1/2 in. NPT
OrientationUprightPendentUprightPendentUprightPendentUprightPendent
K-factor4.2K4.2K5.6K5.6K8.0K8.0K8.0K8.0K
Thread1/2 in. NPT1/2 in. NPT1/2 in. NPT1/2 in. NPT3/4 in. NPT3/4 in. NPT1/2 in. NPT1/2 in. NPT
ResponseQuick ResponseQuick ResponseQuick ResponseQuick ResponseQuick ResponseQuick ResponseQuick ResponseQuick Response
Discharge CoefficientK=4.2 gpm/psi½ (60,5 Lpm/bar½)K=4.2 gpm/psi½ (60,5 Lpm/bar½)K=5.6 gpm/psi½ (80,6 Lpm/bar½)K=5.6 gpm/psi½ (80,6 Lpm/bar½)K=8.0 gpm/psi½ (115,2 Lpm/bar½)K=8.0 gpm/psi½ (115,2 Lpm/bar½)K=8.0 gpm/psi½ (115,2 Lpm/bar½)K=8.0 gpm/psi½ (115,2 Lpm/bar½)
Maximum Working PressureSee Table DSee Table DSee Table DSee Table DSee Table DSee Table DSee Table DSee Table D
Temperature RatingSee Tables A, B, and CSee Tables A, B, and CSee Tables A, B, and CSee Tables A, B, and CSee Tables A, B, and CSee Tables A, B, and CSee Tables A, B, and CSee Tables A, B, and C
FinishesSprinkler: See Table ESprinkler: See Table ESprinkler: See Table ESprinkler: See Table ESprinkler: See Table ESprinkler: See Table ESprinkler: See Table ESprinkler: See Table E
Recessed EscutcheonSignal or Pure White, Grey Aluminum, Jet Black, Chrome Plated, or Natural Brass
FrameBronze
ButtonBrass/Copper

Specifications as published by Tyco. Please confirm the exact model with us before ordering.

More Tyco Standard Spray Sprinklers

Fire Sprinklers from other brands

Savemax

Savemax Flexible Drop for Sprinklers (700 to 1800 mm)

Flexible dropSprinkler connector700 to 1800 mm

A flexible hose connector that links the rigid sprinkler branch pipe above a false ceiling to the sprinkler head below it. It takes up building movement, ceiling deflection and installation misalignment, so the head can be positioned without cutting or re-routing pipe.

View specifications ›

See all fire sprinklers ›

Ask price
Call +91 92440 89060Send a text messageEmail usWhatsApp us