Tyco Series DS-2 Dry-Type Extended Coverage Pendent Sprinkler, K11.2, Light and Ordinary Hazard (TFP540)
Tyco logoSupplier for Tyco

Tyco Series DS-2 Dry-Type Extended Coverage Pendent Sprinkler, K11.2, Light and Ordinary Hazard (TFP540)

Dry-typePendentExtended coverageK11.2TFP540

A K11.2 dry-type extended coverage pendent for light and ordinary hazard occupancies (ECLH and ECOH), for drops into freezers or from unheated parts of a dry pipe system.

  • Extended coverage for light or ordinary hazard
  • Must be installed only in fittings that meet the data sheet's design criteria
  • Inlet thread 1 in. NPT or ISO 7-R 1
  • Temperature ratings printed in the data sheet: 68°C, 79°C, 93°C, 141°C and 182°C
  • Maximum working pressure 175 psi (12.1 bar)
  • Tyco lists UL and C-UL listing

Standards and approvals: UL and C-UL Listed

Sizes: 11.2 K-factor

Ask price & availability

Download the official Tyco catalogue (PDF, 4.6 MB)

Specifications

Specifications
Specification11.2 K-factorTY5238
InletCopper
YokeStainless Steel
CasingGalvanized Carbon Steel
InsertBronze
Bulb SeatBronze
BulbGlass
Compression ScrewBronze
DeflectorBronze
FrameBronze
Guide TubeStainless Steel
Water TubeStainless Steel
SpringStainless Steel
PlugCopper Gasketed Spring
Plate SealBeryllium Nickel w/TEFLON
PinStainless Steel
Button SpringStainless Steel
EscutcheonCarbon Steel
SINTY5238
K-factor11.2 K-factor
Inlet Thread Connections1 in. NPT or ISO 7-R 1
Discharge CoefficientSee Table C
Maximum Working Pressure175 psi (12,1 bar)
Temperature RatingsSee Table A
FinishesSee Table E

Specifications as published by Tyco. Please confirm the exact model with us before ordering.

More Tyco Dry Sprinklers

Fire Sprinklers from other brands

Savemax

Savemax Flexible Drop for Sprinklers (700 to 1800 mm)

Flexible dropSprinkler connector700 to 1800 mm

A flexible hose connector that links the rigid sprinkler branch pipe above a false ceiling to the sprinkler head below it. It takes up building movement, ceiling deflection and installation misalignment, so the head can be positioned without cutting or re-routing pipe.

View specifications ›

See all fire sprinklers ›

Ask price
Call +91 92440 89060Send a text messageEmail usWhatsApp us