ISO 9001:2015 Certified · MSME Registered · Military Engineering Services Registered
Fire Protection System logoFIRE PROTECTION SYSTEMTMFire safety contractors, dealers & distributors · Bhopal, M.P.
EXCELLENCE IN FIRE EXTINGUISHER, FIRE HYDRANT, FIRE ALARM & FIRE SUPPRESSION SYSTEMS
Tyco Series DS-1 Dry-Type Pendent, Upright and Horizontal Sidewall Sprinklers, K5.6, Standard Response (TFP500)
Tyco logoSupplier for Tyco

Tyco Series DS-1 Dry-Type Pendent, Upright and Horizontal Sidewall Sprinklers, K5.6, Standard Response (TFP500)

Dry-typeStandard responseK5.6UL, C-UL, FM, LPCB, VdS, CETFP500

Standard response (5 mm bulb), standard coverage dry-type glass bulb sprinklers for freezer drops, unheated areas and seasonally drained systems.

  • K-factor 5.6 gpm/psi½ (80.6 Lpm/bar½)
  • Pendent, upright and horizontal sidewall styles
  • Inlet thread 1 in. NPT or ISO 7-R 1
  • Temperature ratings printed in the data sheet: 68°C, 79°C, 93°C, 141°C and 182°C
  • Maximum working pressure 175 psi (12.1 bar)
  • Tyco lists UL and C-UL listing, FM, LPCB and VdS approval, and CE certification

Standards and approvals: UL and C-UL Listed, FM Approved, LPCB Approved, VdS Approved, CE Certified

Ask price & availability

Download the official Tyco catalogue (PDF, 4.6 MB)

Specifications

Specifications
SpecificationK=5.6 gpm/psi½ (80,6 Lpm/bar½)PendentUprightHorizonta L Sidewal L
InletCopper
PlugCopper
YokeStainless Steel
CasingGalvanized Carbon Steel
InsertBronze
Bulb SeatStainless Steel
Bulb (5 mm dia.)Glass
Compression ScrewBronze
DeflectorBronze
FrameBronze
Guide TubeStainless Steel
Water TubeStainless Steel
SpringStainless Steel
SINTY3255TY3155TY3355
SIN entry as printedPendentUprightHorizontal Sidewall
OrientationPendentUprightHorizontal Sidewall
K-factor5.6 K-factor5.6 K-factor5.6 K-factor
Inlet Thread Connections1 in. NPT ISO 7-R 11 in. NPT ISO 7-R 11 in. NPT ISO 7-R 1
ResponseStandard ResponseStandard ResponseStandard Response
Discharge CoefficientK=5.6 gpm/psi½ (80,6 Lpm/bar½)K=5.6 gpm/psi½ (80,6 Lpm/bar½)K=5.6 gpm/psi½ (80,6 Lpm/bar½)
Maximum Working Pressure175 psi (12,1 bar)175 psi (12,1 bar)175 psi (12,1 bar)
Temperature RatingsSee Tables A and BSee Tables A and BSee Tables A and B
FinishesSprinkler and Escutcheon, see Table DSprinkler and Escutcheon, see Table DSprinkler and Escutcheon, see Table D

Specifications as published by Tyco. Please confirm the exact model with us before ordering.

More Tyco Dry Sprinklers

Fire Sprinklers from other brands

Savemax

Savemax Flexible Drop for Sprinklers (700 to 1800 mm)

Flexible dropSprinkler connector700 to 1800 mm

A flexible hose connector that links the rigid sprinkler branch pipe above a false ceiling to the sprinkler head below it. It takes up building movement, ceiling deflection and installation misalignment, so the head can be positioned without cutting or re-routing pipe.

View specifications ›

See all fire sprinklers ›