Tyco Series DS-8 Dry-Type Pendent and Horizontal Sidewall Sprinklers, K8.0, Quick Response (TFP513)
Tyco logoSupplier for Tyco

Tyco Series DS-8 Dry-Type Pendent and Horizontal Sidewall Sprinklers, K8.0, Quick Response (TFP513)

Dry-typeQuick responseK8.0UL, C-ULTFP513

Quick response (3 mm bulb), standard coverage dry-type glass bulb sprinklers with a K8.0 orifice, for use in wet pipe, dry pipe or preaction systems where freezing is a risk.

  • K-factor 8.0 gpm/psi½ (115.2 Lpm/bar½)
  • Pendent and horizontal sidewall styles
  • Inlet thread 1 in. NPT or ISO 7-R 1
  • Temperature ratings printed in the data sheet: 68°C, 79°C, 93°C, 141°C and 182°C
  • Maximum working pressure 175 psi (12.1 bar); the standard response version is in TFP503
  • Tyco lists UL and C-UL listing

Standards and approvals: UL and C-UL Listed

Ask price & availability

Download the official Tyco catalogue (PDF, 4.6 MB)

Specifications

Specifications
SpecificationK=8.0 gpm/psi½ (115,2 lpm/bar½)PendentHorizonta L Sidewal L
InletBrass
PlugBrass
YokeStainless Steel
CasingGalvanized Carbon Steel
Bulb SeatStainless Steel
Bulb (3 mm dia.)Glass
Compression ScrewBrass
DeflectorBronze
FrameBrass
Guide TubeStainless Steel
Water TubeStainless Steel
SpringStainless Steel
SINTY4235TY4335
SIN entry as printedPendentHorizontal Sidewall
OrientationPendentHorizontal Sidewall
K-factor8.0 K-factor8.0 K-factor
Inlet Thread Connections1 in. NPT ISO 7-R 11 in. NPT ISO 7-R 1
ResponseQuick ResponseQuick Response
Discharge CoefficientK=8.0 gpm/psi½ (115,2 lpm/bar½)K=8.0 gpm/psi½ (115,2 lpm/bar½)
Maximum Working Pressure175 psi (12,1 bar)175 psi (12,1 bar)
Temperature RatingsSee Table A and Table BSee Table A and Table B
FinishesSprinkler: See Table D Escutcheon: See Table DSprinkler: See Table D Escutcheon: See Table D

Specifications as published by Tyco. Please confirm the exact model with us before ordering.

More Tyco Dry Sprinklers

Fire Sprinklers from other brands

Savemax

Savemax Flexible Drop for Sprinklers (700 to 1800 mm)

Flexible dropSprinkler connector700 to 1800 mm

A flexible hose connector that links the rigid sprinkler branch pipe above a false ceiling to the sprinkler head below it. It takes up building movement, ceiling deflection and installation misalignment, so the head can be positioned without cutting or re-routing pipe.

View specifications ›

See all fire sprinklers ›

Ask price
Call +91 92440 89060Send a text messageEmail usWhatsApp us