Sidewall Sprinklers (Side Wall Sprinkler Heads) in Bhopal
A sidewall sprinkler is fixed on a wall just below the ceiling and throws water forward across the room, so the pipe can run along the wall instead of across the ceiling. It is used in hotel rooms, hostels, corridors, small offices and refits where the ceiling cannot be opened. This page compares 36 sidewall models from Tyco, Savemax, HD Fire, Kartar Valves, New Age and Balaji Fire Safety: horizontal and vertical sidewall heads, extended coverage, concealed, residential and dry heads.
- Also called
- side wall sprinkler, horizontal sidewall sprinkler, HSW sprinkler, vertical sidewall sprinkler, wall sprinkler
- Used for
- Hotel rooms, hostels, corridors, small offices, refits and rooms without a false ceiling
- Brands
- Tyco, Savemax, HD Fire, Kartar Valves, New Age, Balaji Fire Safety
- Supplied by
- Fire Protection System, Bhopal (supplier for Tyco and New Age; authorised distributor for Savemax and Kartar Valves; dealer for HD Fire and Balaji Fire Safety), across Madhya Pradesh
- Price
- On request: WhatsApp or call +91 92440 89060
Which one do you need?
| Hotel room or small office | Standard sidewall |
|---|---|
| Wider rooms with fewer heads | Extended coverage |
| Hidden in the wall | Concealed sidewall |
| Flats and hostels | Residential sidewall |
| Balconies and cold areas | Dry sidewall |
Horizontal or vertical sidewall?
A horizontal sidewall head comes out of the wall on a short horizontal pipe, with its deflector facing into the room. A vertical sidewall head sits on a pipe running up or down the wall and has a deflector shaped to throw the water sideways. Both spray a half circle of water across the room and onto the wall opposite.
Sidewall heads save running pipe across the ceiling, which helps in hotel rooms where the pipe can run above the corridor ceiling and enter each room through the wall, and in refits of finished buildings.
Each head is listed for a set throw and width, so the room size decides how many are needed. Extended coverage sidewall heads throw further, so one head can cover a larger room.
- Hotel rooms
- Hostels and flats
- Corridors
- Small offices and cabins
- Refits of finished buildings
- Rooms with exposed beams or no ceiling void
Horizontal and vertical sidewall sprinklers
HD Fire offers UL Listed horizontal sidewall heads, one also FM Approved, and a vertical sidewall head; New Age makes UL Listed sidewall heads in quick and standard response; Kartar K908.I and Savemax sidewall heads are ISI marked; and Tyco TY-B, TY-FRB and TY-L sidewall heads are UL and FM approved as listed.
Extended coverage sidewall sprinklers
Heads that throw further, so one covers a larger room: the HD Fire HSW quick response head in K 5.6 and K 8, and Tyco EC-5, TY-FRB, TY-FRL, EC-HS and SW-20 and SW-24 extended coverage heads, plus the concealed RFIII and CHEC.
Concealed sidewall sprinklers
Sidewall heads hidden behind a flat cover plate in the wall: Tyco RFII flat plate, RFIII and CHEC.
| Model | Key facts |
|---|---|
| Tyco Model RFII Flat Plate Concealed Horizontal Sidewall Sprinkler, K5.6, Quick Response (TFP185) | Concealed sidewall, K5.6, Quick response, UL, C-UL, FM |
| Tyco Model CHEC Concealed Horizontal Extended Coverage Sidewall Sprinkler, K8.0, Quick Response (TFP265) | Concealed sidewall, K8.0, QREC, UL, C-UL |
| Tyco Model RFIII Flat Plate Concealed Horizontal Extended Coverage Sidewall Sprinkler, K8.0, Quick Response (TFP270) | Concealed sidewall, K8.0, QREC, UL, C-UL |
Residential sidewall sprinklers
Tyco LFII residential horizontal sidewall heads for flats, hostels and homes, in K4.2 to K5.8, including concealed versions.
| Model | Key facts |
|---|---|
| Tyco Series LFII Residential Horizontal Sidewall Sprinkler (TY1334), K4.2, Wet and Dry Pipe (TFP410) | Residential sidewall, K4.2, Wet and dry pipe, UL, C-UL |
| Tyco Series LFII Residential Horizontal Sidewall Sprinkler (TY2334), K4.4, Wet Pipe (TFP412) | Residential sidewall, K4.4, Wet pipe, UL, C-UL |
| Tyco Series LFII Residential Horizontal Sidewall Sprinkler (TY3334), K5.6, NFPA 13 Optimized (TFP415) | Residential sidewall, K5.6, NFPA 13 optimized, UL, C-UL |
| Tyco Series LFII Residential Horizontal Sidewall Sprinkler (TY4334), K5.8, NFPA 13 Optimized (TFP417) | Residential sidewall, K5.8, NFPA 13 optimized, UL, C-UL, FM |
| Tyco Series LFII Residential Concealed Horizontal Sidewall Sprinkler (TY2324), K4.2, Wet Pipe (TFP445) | Concealed sidewall, K4.2, Fusible link, UL, C-UL |
Dry sidewall sprinklers
Tyco dry-type sidewall heads for balconies, porches and cold areas fed from a heated room.
Window and institutional sidewall sprinklers
Tyco window sprinklers that wet glazing, and institutional heads that resist tampering for secure rooms.
| Model | Key facts |
|---|---|
| Tyco Model WS Specific Application Window Sprinkler, Horizontal and Pendent Vertical Sidewall, K5.6 (TFP620) | Window sprinkler, Fast response, glass bulb, K5.6, Brass |
| Tyco Model CWS Concealed Window Sprinkler, Pendent Vertical Sidewall, K5.6 (TFP621) | Concealed window sprinkler, Fast response, solder link, K5.6, Brass |
| Tyco RAVEN 5.6K Institutional Sprinklers, Pendent and Horizontal Sidewall, Quick Response (TFP651) | Institutional sprinkler, Pendent and sidewall, Quick response, K5.6 |
| Tyco Model TFP PH5 Institutional Horizontal Sidewall Sprinkler, K5.6, Standard Response (TFP654) | Institutional sprinkler, Horizontal sidewall, Standard response, K5.6 |
How to choose
Measure the room: its length and width set how many sidewall heads are needed and which coverage they must give. A standard head suits small rooms, and extended coverage heads larger ones.
Mount the head at the height below the ceiling its listing gives, and keep its throw clear of beams, lights and tall furniture.
Choose horizontal or vertical by how the pipe reaches the wall, and match the K factor, response and temperature to the design.
Frequently asked questions
What is a sidewall sprinkler?
What is a horizontal sidewall (HSW) sprinkler?
How far does a sidewall sprinkler throw?
Can a sidewall sprinkler replace a pendent one?
What is the price of a sidewall sprinkler in Bhopal?

Need a Fire NOC or renewal in Madhya Pradesh?
We handle your complete Fire NOC application and renewal: documentation, liaison with the MP Fire Department and compliance support.