ISO 9001:2015 Certified · MSME Registered · Military Engineering Services Registered
Fire Protection System logoFIRE PROTECTION SYSTEMTMFire safety contractors, dealers & distributors · Bhopal, M.P.
EXCELLENCE IN FIRE EXTINGUISHER, FIRE HYDRANT, FIRE ALARM & FIRE SUPPRESSION SYSTEMS

Sidewall Sprinklers (Side Wall Sprinkler Heads) in Bhopal

A sidewall sprinkler is fixed on a wall just below the ceiling and throws water forward across the room, so the pipe can run along the wall instead of across the ceiling. It is used in hotel rooms, hostels, corridors, small offices and refits where the ceiling cannot be opened. This page compares 36 sidewall models from Tyco, Savemax, HD Fire, Kartar Valves, New Age and Balaji Fire Safety: horizontal and vertical sidewall heads, extended coverage, concealed, residential and dry heads.

Also called
side wall sprinkler, horizontal sidewall sprinkler, HSW sprinkler, vertical sidewall sprinkler, wall sprinkler
Used for
Hotel rooms, hostels, corridors, small offices, refits and rooms without a false ceiling
Brands
Tyco, Savemax, HD Fire, Kartar Valves, New Age, Balaji Fire Safety
Supplied by
Fire Protection System, Bhopal (supplier for Tyco and New Age; authorised distributor for Savemax and Kartar Valves; dealer for HD Fire and Balaji Fire Safety), across Madhya Pradesh
Price
On request: WhatsApp or call +91 92440 89060

Which one do you need?

Hotel room or small officeStandard sidewall
Wider rooms with fewer headsExtended coverage
Hidden in the wallConcealed sidewall
Flats and hostelsResidential sidewall
Balconies and cold areasDry sidewall

Horizontal or vertical sidewall?

A horizontal sidewall head comes out of the wall on a short horizontal pipe, with its deflector facing into the room. A vertical sidewall head sits on a pipe running up or down the wall and has a deflector shaped to throw the water sideways. Both spray a half circle of water across the room and onto the wall opposite.

Sidewall heads save running pipe across the ceiling, which helps in hotel rooms where the pipe can run above the corridor ceiling and enter each room through the wall, and in refits of finished buildings.

Each head is listed for a set throw and width, so the room size decides how many are needed. Extended coverage sidewall heads throw further, so one head can cover a larger room.

  • Hotel rooms
  • Hostels and flats
  • Corridors
  • Small offices and cabins
  • Refits of finished buildings
  • Rooms with exposed beams or no ceiling void

Horizontal and vertical sidewall sprinklers

HD Fire offers UL Listed horizontal sidewall heads, one also FM Approved, and a vertical sidewall head; New Age makes UL Listed sidewall heads in quick and standard response; Kartar K908.I and Savemax sidewall heads are ISI marked; and Tyco TY-B, TY-FRB and TY-L sidewall heads are UL and FM approved as listed.

ModelKey facts
Tyco Series TY-L Standard Response Horizontal Sidewall Sprinkler, K5.6 (TFP120)Horizontal sidewall, Standard response, K5.6, Solder type
Tyco Series TY-B Standard Response Horizontal and Vertical Sidewall Sprinklers, K5.6 (TFP161)Sidewall, Standard response, 5 mm glass bulb, K5.6
Tyco Series TY-FRB Quick Response Horizontal and Vertical Sidewall Sprinklers, K5.6 (TFP176)Sidewall, Quick response, 3 mm glass bulb, K5.6
Savemax ISI Marked Sprinklers, Pendant, Upright and SidewallSprinkler, Pendant, upright, sidewall, 68°C bulb, IS 15105
HD Fire Horizontal Sidewall Sprinkler, K 8, UL ListedHorizontal sidewall, K 8, ¾ inch, UL Listed
HD Fire Horizontal Sidewall Sprinkler, UL Listed and FM ApprovedHorizontal sidewall, Glass bulb, Standard or quick response, UL Listed and FM Approved
HD Fire Vertical Sidewall Sprinkler, K 5.6, UL ListedVertical sidewall, K 5.6, Light and ordinary hazard, UL Listed
Kartar Valves Forged Brass Sprinkler, 15 mm, 68°C, Pendent, Upright and SidewallForged brass, 15 mm screwed, 68°C, 175 psi
New Age Sidewall Sprinkler, Quick Response, UL ListedUL Listed, Sidewall, Quick response, Bronze
New Age Sidewall Sprinkler, Standard Response, UL ListedUL Listed, Sidewall, Standard response, Bronze
Balaji Fire Safety Sidewall Sprinkler, Brass, 68°CSidewall, Brass, 68°C, ½ inch

Extended coverage sidewall sprinklers

Heads that throw further, so one covers a larger room: the HD Fire HSW quick response head in K 5.6 and K 8, and Tyco EC-5, TY-FRB, TY-FRL, EC-HS and SW-20 and SW-24 extended coverage heads, plus the concealed RFIII and CHEC.

Concealed sidewall sprinklers

Sidewall heads hidden behind a flat cover plate in the wall: Tyco RFII flat plate, RFIII and CHEC.

Residential sidewall sprinklers

Tyco LFII residential horizontal sidewall heads for flats, hostels and homes, in K4.2 to K5.8, including concealed versions.

Dry sidewall sprinklers

Tyco dry-type sidewall heads for balconies, porches and cold areas fed from a heated room.

Window and institutional sidewall sprinklers

Tyco window sprinklers that wet glazing, and institutional heads that resist tampering for secure rooms.

ModelKey facts
Tyco Model WS Specific Application Window Sprinkler, Horizontal and Pendent Vertical Sidewall, K5.6 (TFP620)Window sprinkler, Fast response, glass bulb, K5.6, Brass
Tyco Model CWS Concealed Window Sprinkler, Pendent Vertical Sidewall, K5.6 (TFP621)Concealed window sprinkler, Fast response, solder link, K5.6, Brass
Tyco RAVEN 5.6K Institutional Sprinklers, Pendent and Horizontal Sidewall, Quick Response (TFP651)Institutional sprinkler, Pendent and sidewall, Quick response, K5.6
Tyco Model TFP PH5 Institutional Horizontal Sidewall Sprinkler, K5.6, Standard Response (TFP654)Institutional sprinkler, Horizontal sidewall, Standard response, K5.6

How to choose

Measure the room: its length and width set how many sidewall heads are needed and which coverage they must give. A standard head suits small rooms, and extended coverage heads larger ones.

Mount the head at the height below the ceiling its listing gives, and keep its throw clear of beams, lights and tall furniture.

Choose horizontal or vertical by how the pipe reaches the wall, and match the K factor, response and temperature to the design.

Frequently asked questions

What is a sidewall sprinkler?
A sprinkler fixed on a wall just below the ceiling that throws water across the room, so the pipe can run along the wall instead of across the ceiling.
What is a horizontal sidewall (HSW) sprinkler?
A sidewall head fed by a short horizontal pipe coming out of the wall, with its deflector facing into the room. A vertical sidewall head sits on a pipe running up or down the wall.
How far does a sidewall sprinkler throw?
Each model is listed for a set throw and width. Extended coverage sidewall heads throw further, so one head can protect a larger room.
Can a sidewall sprinkler replace a pendent one?
Only where the design allows it. The room size and the head's listing decide how many sidewall heads are needed, so we check the layout first. Under a false ceiling, pendent sprinklers are usual.
What is the price of a sidewall sprinkler in Bhopal?
It depends on the brand, the K factor, the response, the finish, the approval (UL, FM or ISI) and the quantity, and makers change their price lists often, so we quote each order instead of listing prices. Send the type, K factor, temperature and quantity on WhatsApp at +91 92440 89060 and we will reply with the current price. Every supply is billed on a GST invoice.

Need a Fire NOC or renewal in Madhya Pradesh?

We handle your complete Fire NOC application and renewal: documentation, liaison with the MP Fire Department and compliance support.

Talk to our NOC team
Call +91 92440 89060Send a text messageEmail usWhatsApp us