Tyco Series TY-FRB Quick Response Upright (TY313) and Pendent (TY323) Sprinklers, K5.6 (TFP172)
Tyco logoSupplier for Tyco

Tyco Series TY-FRB Quick Response Upright (TY313) and Pendent (TY323) Sprinklers, K5.6 (TFP172)

Quick response3 mm glass bulbK5.6UL, C-UL, FM, LPCBTFP172

K5.6 glass bulb quick response, standard coverage spray sprinklers with a 3 mm bulb for light or ordinary hazard buildings, with a recessed pendent option for finished ceilings.

  • K-factor 5.6 gpm/psi½ (80.6 Lpm/bar½)
  • Recessed pendent with a two-piece Style 15 escutcheon (up to 5/8 in. of recessed adjustment) or Style 20 escutcheon (up to 1/2 in.)
  • Maximum working pressure 175 psi (12.1 bar), or 250 psi (17.2 bar) under the UL and C-UL listings
  • Temperature ratings printed in the data sheet: 57°C, 68°C, 79°C, 93°C and 141°C
  • Unshielded TY313 and TY323 for in-rack use under solid shelves; intermediate level versions are covered in TFP357
  • Tyco lists UL and C-UL listing and FM and LPCB approval

Standards and approvals: Listed by Underwriters Laboratories, Inc., (UL), Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL), Approved by Factory Mutual Research Corporation (FM), Approved by the Loss Prevention Certification Board

Ask price & availability

Download the official Tyco catalogue (PDF, 4.6 MB)

Specifications

Specifications
SpecificationUpright 5.6K, 1/2 in. NPTPendent 5.6K, 1/2 in. NPTK=5.6 GPM/psi½ (80,6 LPM/bar½)
SINTY313TY323
SIN entry as printedUpright 5.6K, 1/2 in. NPTPendent 5.6K, 1/2 in. NPT
OrientationUprightPendent
K-factor5.6K5.6K
Thread1/2 in. NPT1/2 in. NPT
ResponseQuick ResponseQuick Response
Discharge CoefficientK=5.6 GPM/psi½ (80,6 LPM/bar½)K=5.6 GPM/psi½ (80,6 LPM/bar½)
Maximum Working Pressure175 psi (12,1 bar) 250 psi (17,2 bar)* * The maximum working pressure of 250 psi (17,2 bar) only applies to the listing by Underwriters Laboratories, Inc. (UL) and to the listing by Underwriters Laboratories, Inc. for use in Canada (C-UL).175 psi (12,1 bar) 250 psi (17,2 bar)* * The maximum working pressure of 250 psi (17,2 bar) only applies to the listing by Underwriters Laboratories, Inc. (UL) and to the listing by Underwriters Laboratories, Inc. for use in Canada (C-UL).
Temperature RatingSee Table ASee Table A
FinishesSprinkler: See Table BSprinkler: See Table B
Recessed EscutcheonWhite Coated, Black Coated, Chrome Plated, or Brass Plated
FrameBronze
ButtonBrass/Copper
Sealing AssemblyStainless Steel w/TEFLON
BulbGlass
Compression ScrewBronze
DeflectorBronze

Specifications as published by Tyco. Please confirm the exact model with us before ordering.

More Tyco Standard Spray Sprinklers

Fire Sprinklers from other brands

Savemax

Savemax Flexible Drop for Sprinklers (700 to 1800 mm)

Flexible dropSprinkler connector700 to 1800 mm

A flexible hose connector that links the rigid sprinkler branch pipe above a false ceiling to the sprinkler head below it. It takes up building movement, ceiling deflection and installation misalignment, so the head can be positioned without cutting or re-routing pipe.

View specifications ›

See all fire sprinklers ›

Ask price
Call +91 92440 89060Send a text messageEmail usWhatsApp us