Siemens OP110 Cerberus FIT Conventional Optical Smoke Detector
A conventional (collective) optical smoke detector for smoke from flaming and smouldering fires, with two selectable parameter sets.

Dealer for SiemensA conventional static (fixed temperature) heat detector for areas with dirt or temperature swings that can cause false alarms from smoke detectors.
Standards and approvals: VdS, UKCA
| Specification | HI112 |
|---|---|
| Operating voltage | DC 16…28 V |
| Operating temperature | -10…50 °C |
| Protection category | IP40; IP42 with detector base seal; IP44 with base attachment wet |
| Storage temperature | -30...+70 °C |
| Relative humidity | ≤96 % rel. |
| Dimensions (Ø x H) | 105 x 51 mm |
| Color | Pure white, ~RAL 9010 |
| Quiescent current | Max. 100 μA |
| Communication protocol | Collective/Conventional |
Specifications as published by Siemens. Please confirm the exact model with us before ordering.
A conventional (collective) optical smoke detector for smoke from flaming and smouldering fires, with two selectable parameter sets.
A conventional multi-sensor detector for flaming fires from liquids and solids and for smouldering fires, built for rooms with deceptive phenomena.
A conventional differential heat detector for areas with heavy dust, dirt or moisture where smoke detectors may give false alarms.
A battery operated, Wi-Fi enabled photoelectric smoke detector from the IMPACT by Honeywell range. When smoke reaches its alarm threshold it sounds a buzzer, flashes an LED and sends real-time alerts to a smartphone through the IMPACT by Honeywell app.
A battery operated standalone smoke alarm with photoelectric sensing that sounds an alarm and lights a red LED when smoke reaches its threshold. It runs on two AA batteries and also warns of a low battery or a chamber fault.
An intelligent addressable photoelectric smoke detector with an optical chamber that senses smoke from a wide range of fires, and sensitivity that is programmable and monitored by the panel.
An intelligent photoelectric smoke detector with dual thermistors that add 135°F (57°C) fixed temperature heat sensing in the same head.
An S200A plug-in photoelectric smoke detector listed with the DXc and ZXSe panels. Its detection chamber is designed to cut false alarms from dust, insects and other debris.
An S200A multi-criteria detector that adds 58°C fixed temperature and rate of rise thermal sensing to a photoelectric smoke sensor, for better false alarm immunity and faster response to a wide range of fires.