ISO 9001:2015 Certified · MSME Registered · Military Engineering Services Registered
Fire Protection System logoFIRE PROTECTION SYSTEMTMFire safety contractors, dealers & distributors · Bhopal, M.P.
EXCELLENCE IN FIRE EXTINGUISHER, FIRE HYDRANT, FIRE ALARM & FIRE SUPPRESSION SYSTEMS
System Sensor 22051E / 22051EI Addressable Photoelectric Smoke Detector (Series 200 Advanced)
Dealer for System Sensor

System Sensor 22051E / 22051EI Addressable Photoelectric Smoke Detector (Series 200 Advanced)

22051E22051EIPhotoelectric smokeSeries 200 AdvancedCPR

A white addressable photoelectric smoke detector working on the light scattering principle, with smoothing filters and embedded software to resist unwanted alarms. The 22051EI version has a built-in isolator.

  • Series 200 Advanced digital protocol
  • 22051E without isolator, 22051EI with single pole short circuit isolation
  • Tri-colour LED (red, green, amber) visible through 360°
  • Rotary decade address switches, full backward compatibility
  • 15 to 32Vdc, -30 to +80°C, 10 to 93% humidity, 97g with base
  • CPR and UKCA

Standards and approvals: CPR, UKCA

Ask price & availability

Specifications

Specifications
Specification22051E22051EI
Operating Voltage Range15 to 32Vdc
Maximum Standby Current200µA at 24VDC (no communications) / 300µA at 24VDC ( LED blink enabled, once every 5s)200µA at 24VDC (no communications) / 300µA at 24VDC ( LED blink enabled, once every 5s)
Led CurrentRed: 3.5mA at 24Vdc | Green: 7.0mA @ 24Vdc | Yellow: 10.5mA @ 24VdcRed: 3.5mA at 24Vdc | Green: 7.0mA @ 24Vdc | Yellow: 10.5mA @ 24Vdc
Remote Out put Voltage22.5Vdc @ 24Vdc22.5Vdc @ 24Vdc
Remote Output Current10.8mA @ 24Vdc10.8mA @ 24Vdc
Additional loop resistance using the B501APtyp 20mohm (max 30 mohm)typ 20mohm (max 30 mohm)
Temperature Range-30°C to +80°C †-30°C to +80°C †
Humidity10 to 93% relative Humidity (non-condensing)10 to 93% relative Humidity (non-condensing)
Height52mm installed in B501AP base52mm installed in B501AP base
Diameter102mm installed in B501AP base102mm installed in B501AP base
Weight97g (inc base)97g (inc base)
Max Wire Gauge for Terminals2.5mm22.5mm2
ColourWhiteWhite
MaterialPC/ABSPC/ABS
Isolation Current15mA at 24VDC
Maximum Continuous Current1A (Switch Closed)

Specifications as published by System Sensor. Please confirm the exact model with us before ordering.