Tyco Series TY-FRB Conventional (Old Style) Sprinklers, K5.6 and K8.0, Quick Response (TFP666)
Tyco logoSupplier for Tyco

Tyco Series TY-FRB Conventional (Old Style) Sprinklers, K5.6 and K8.0, Quick Response (TFP666)

Old style sprinklerQuick response, 3 mm bulbK5.6 and K8.0BronzeUL, C-UL, LPCB, VdS

Quick response, standard coverage old style sprinklers with a 3 mm glass bulb, fitted upright or pendent, giving a spherical pattern with roughly half the water up and half down.

  • K-factors 5.6 and 8.0; maximum working pressure 175 psi
  • Temperature ratings from 57°C (135°F) to 141°C (286°F)
  • Generally used in ordinary and extra high hazard systems under the local installation rules
  • Corrosion resistant coatings available where applicable
  • Bronze; Tyco lists UL and C-UL Listing and LPCB and VdS Approval, with details in Table A

Standards and approvals: UL and C-UL Listed, LPCB Approved, VdS Approved

Sizes: 5.6K, 1/2 in. NPT, 8.0K, 3/4 in. NPT

Ask price & availability

Download the official Tyco catalogue (PDF, 4.6 MB)

Specifications

Specifications
Specification5.6K, 1/2 in. NPT8.0K, 3/4 in. NPTDetails
SINTY3631TY4631
SIN entry as printed5.6K, 1/2 in. NPT8.0K, 3/4 in. NPT
K-factor5.6K8.0K
Thread1/2 in. NPT3/4 in. NPT
ResponseQuick ResponseQuick Response
Discharge CoefficientK=5.6 gpm/psi½ (80,6 Lpm/bar½)K=8.0 gpm/psi½ (115,2 Lpm/bar½)
Maximum Working Pressure175 psi (12,1 bar)175 psi (12,1 bar)
Temperature RatingsSee Table ASee Table A
FinishesSprinkler: See Table ASprinkler: See Table A
FrameBronze
ButtonBrass/Copper

Specifications as published by Tyco. Please confirm the exact model with us before ordering.

More Tyco Special Application Sprinklers

Fire Sprinklers from other brands

Savemax

Savemax Flexible Drop for Sprinklers (700 to 1800 mm)

Flexible dropSprinkler connector700 to 1800 mm

A flexible hose connector that links the rigid sprinkler branch pipe above a false ceiling to the sprinkler head below it. It takes up building movement, ceiling deflection and installation misalignment, so the head can be positioned without cutting or re-routing pipe.

View specifications ›

See all fire sprinklers ›

Ask price
Call +91 92440 89060Send a text messageEmail usWhatsApp us