Fire suppression systems detect a fire and discharge an agent automatically, inside a panel or machine, across a whole room, or around a transformer or generator, so the fire is stopped where it starts. FPS offers tube based cabinet systems, clean agent and inert gas room flooding systems, modular units and watermist systems from Ceasefire, Kanex, Minimax, Savemax, HD Fire and Honeywell in Bhopal and across Madhya Pradesh.

Ceasefire

Ceasefire Atom X Automatic Fire Suppression System, Ceiling Mounted

Total floodingFK or MAP 90Ceiling mounted

Sizes: 2 kg, 5 kg, 10 kg, 15 kg

Pre-engineered, retrofittable suppression system built from ceiling mounted agent containers in 2, 5, 10 and 15 kg, linked to detectors and a control panel. It comes with Fluoroketone (FK) clean agent or ABC powder MAP 90, and all units fire together for total flooding.

View specifications ›
Ceasefire

Ceasefire Indoor Auto-Quell Watermist Suppression System

WatermistIndoor areasDroplets below 100 microns

Watermist detection and suppression system for indoor areas, with detection devices, mist nozzles and a water tank connection, discharging droplets below 100 microns. It works automatically, and operations can resume quickly as there are no chemicals to clean up.

View specifications ›
Ceasefire

Ceasefire M Series Total Flooding Solution

Total floodingM SeriesFK, MAP 90 or MAP 50

A scalable flooding system built from M Series wall and ceiling mounted extinguisher units fitted with Metron actuators and linked to detectors through a control panel. Agent options are Fluoroketone (FK-5-1-12), ABC powder MAP 90 and ABC powder MAP 50.

View specifications ›
Ceasefire

Ceasefire SWIFT Watermist Suppression System

WatermistCommercial premisesAutomatic and manual

Watermist suppression system for commercial premises, with automatic detection and a manual trigger, in sizes and layouts that can be customised. Clean water leaves no toxic chemicals, so offices can get back to work quickly.

View specifications ›
Kanex

Kanex Clean Agent Direct Low Pressure (DLP) Panel and Rack Suppression System

Clean agent FE-36, FK-5-1-12 or FM-200Direct release (DLP)2, 4, 6 kg

Sizes: 2, 4, 6 kg

Pre-engineered clean agent system for electrical cabinets, server racks and wind turbine alternator zones, where the UL listed detection tube both senses the fire and delivers the agent at the source. Available in 2, 4 and 6 kg cylinders with FE-36 (HFC-236fa), FK-5-1-12 or FM-200 (HFC-227ea).

View specifications ›
Kanex

Kanex CO2 Indirect High Pressure (IHP) Suppression System

CO2 agentIndirect release (IHP)4.5 to 45 kg

Sizes: 4.5, 6.5, 9, 22.5, 45 kg

Indirect high pressure CO2 systems for panels, dry type transformers and generators, CNC and EDM machines and fume hoods, where the detection tube senses the fire and nozzles deliver CO2 as a gentle mist. Cylinder sizes from 4.5 kg up to 45 kg depending on the enclosure.

View specifications ›
Kanex

Kanex Clean Agent Total Flooding System (FM-200 or Novec 1230)

FM-200 or Novec 1230Engineered total floodingRoom protection

Engineered total flooding systems that fill a room with FM-200 (HFC-227ea) or Novec 1230 to put out a fire without wetting or contaminating equipment. Designed for server rooms, data centres and other areas where water would cause as much loss as the fire.

View specifications ›
Kanex

Kanex Room Protection System with Detector and Alarm Panel

Electrically actuatedDetector and alarm panelRoom protection

An electrically actuated room system in which smoke detectors signal a fire alarm panel, which opens the control valve and releases the extinguishing media into the affected area. The panel also drives a hooter and can send SMS alerts and calls.

View specifications ›
Kanex

Kanex Direct Release Tube Systems

Direct releaseFiretrace detection tubingEnclosure protection

Direct release systems in which the heat and flame sensitive Firetrace detection tubing serves as both the detector and the agent delivery line. Used for small enclosures where suppression is needed right at the source.

View specifications ›
Kanex

Kanex Indirect Release Tube Systems

Indirect releaseFiretrace detection tubingNozzle discharge

Indirect release systems where the Firetrace detection tubing only detects the fire and activates the system, and the agent is discharged through separate nozzles. Recommended for larger machine enclosures.

View specifications ›
Kanex

Kanex Fire Suppression Agents and Refills

Dry chemicalClean agentsCO2

The range of extinguishing media used with Kanex suppression hardware, covering dry chemical powders, clean agents and carbon dioxide. The right agent depends on the hazard and the equipment being protected.

View specifications ›
Savemax

Savemax Panel Protection System, Automatic Clean Agent

Clean agentAutomatic detection and suppressionElectrical panels

An automatic suppression system for electrical panels, switchgear, control cabins and server racks that detects a fire and puts it out at the source. It uses a clean agent that leaves no residue and is safe on live panels.

View specifications ›
HD Fire

HD Fire HD-RAKSHAK In-Cabinet CO2 Suppression System (IHP)

CO2 agentIn-cabinet system60 bar

Sizes: 2 kg to 18 kg

An in-cabinet fire suppression system that uses CO2, with a UL Listed heat-sensing tube for detection and an automatic IHP valve in brass. The detection tube is charged with CO2 from the system cylinder, so it needs no separate nitrogen cylinder.

View specifications ›
Honeywell

Honeywell Rack Mount Fire Suppression System

Rack mountFK-5-1-121.5 to 3 m3 racks

A do-it-yourself suppression unit for equipment racks that uses a clean agent safe for PCBs. It covers racks of 1.5 m3 to 3 m3 and uses cross zone smoke detection to help reduce the risk of electrical fires.

View specifications ›
Honeywell

Honeywell IG-541 Inert Gas Fire Suppression System

IG-541Inert gas200 and 300 bar

Sizes: 30 L, 50 L, 80 L, 140 L

An inert gas system that puts out class A, B and C fires by lowering the oxygen level in the room, using a blend of 52% nitrogen, 40% argon and 8% CO2. It comes as a stand-alone system for one space or as a multi-zone system.

View specifications ›
Honeywell

Honeywell Manifold Discharge Pressure Switch

Pressure switchDischarge confirmation6 A rating

A switch mounted on the manifold or piping that operates under discharge pressure and signals the panel that the system has actuated. It has a reset button that must be pressed after a discharge.

View specifications ›

How to choose

Start with what you protect. For a single electrical panel, server rack or machine, a tube based system is usually enough: a pressurised heat sensing tube runs through the enclosure and bursts at the hot spot, 150 to 180 C in the Ceasefire range. Direct systems use the burst tube as the nozzle and discharge right at the fire, while indirect systems use the tube only to detect and send the agent through separate nozzles, which suits larger or compartmentalised enclosures such as CNC and EDM machines, dry type transformers and DG sets. Ceasefire, Kanex (Firetrace tubing), Minimax (FIRESPOT), Savemax and HD Fire (HD-RAKSHAK CO2) all offer panel systems, and Honeywell ECS kits come in direct (1.13 to 4.54 kg) and indirect (1.36 to 6.35 kg) versions with FK-5-1-12. For server racks, the Ceasefire SQRS and the Honeywell Rack Mount unit, for racks of 1.5 to 3 m3, combine smoke detection and agent in one unit.

For whole rooms such as server rooms, data centres, UPS rooms and record rooms, choose total flooding, where detectors signal a panel that releases agent through pipes and nozzles into the room. Clean agent options are Ceasefire HFC 227ea and fluoroketone systems that reach extinguishing levels in 10 seconds or less, Kanex engineered FM-200 or Novec 1230 systems, Honeywell FK-5-1-12 systems at 25, 34.5 or 42 bar (with INFERNO SHIELD for large, high risk volumes) and HFC-227ea systems at 25 or 42 bar, and the ceiling mounted 10 kg Minimax Grenoz 1230 unit for small unmanned rooms. Inert gas systems lower the oxygen level instead: the Ceasefire VdS approved system scales up to 240 cylinders, HD Fire HD-INERTSYS uses IG55, IG541, IG100 or IG01 in 80 and 140 litre cylinders at 200 or 300 bar, and Honeywell IG-541 works at 200 or 300 bar with 30 to 140 litre cylinders. Without a large pipe network, the Ceasefire Atom X and M Series link ceiling units of 2 to 15 kg into one flooding system.

Then match the agent to the equipment. Clean agents (FK-5-1-12, Novec 1230, Grenoz 1230, HFC 227ea or FM-200, HFC 236fa or FE-36) are electrically non conductive and leave no residue, for electronics and live panels, and Honeywell presents its HFC-227ea, INFERNO SHIELD and IG-541 systems as suitable where people are present. CO2 cools and reduces oxygen in panels, transformers and machines, with Kanex cylinders from 4.5 kg to 45 kg at 60 to 70 bar and the HD-RAKSHAK at 60 bar. ABC powder MAP 90 covers mixed fire classes in enclosures, fluorine free foam suits oil and petrol, and the Ceasefire Auto-Quell and SWIFT watermist systems for generators, transformers, indoor areas and offices use water only, with the Auto-Quell range working without a power supply.

Finally check approvals, components and alarms. Ceasefire tube systems are LPCB tested (under LPS 1666 for fluoroketone and HFC 236fa) or BSI tested and CE certified, depending on the agent; Kanex lists UL, FM, CE and EPA SNAP approvals with CCOE cylinders and gas to IS 15222 for CO2; Honeywell lists NFPA 2001, PESO and IS 7285 for its FK-5-1-12 and HFC-227ea systems, with UL listing on FK-5-1-12, and FM approval and UL listing on IG-541; HD-INERTSYS carries VdS approval; and Minimax FIRESPOT carries National Test House approval. For engineered Honeywell systems FPS also supplies seamless cylinders from 34 to 180 litres, manifold check valves, discharge hoses, 180 or 360 degree brass nozzles, electric and pneumatic control heads and discharge pressure switches. A pressure switch can report a discharge to a fire alarm panel or BMS, and options include GSM diallers, hooters and the IP monitoring module on the Ceasefire SQRS.

Frequently asked questions

What is the difference between direct and indirect tube systems?
In a direct system the heat sensing tube detects the fire and also discharges the agent from the point where it bursts. In an indirect system the tube only detects, and the agent flows through a separate line to fixed nozzles, which suits larger enclosures and machines.
Do these systems need electrical power?
Ceasefire tube systems, the Ceasefire Mini microenvironment units and the Auto-Quell watermist systems work without a power supply. Room systems that use detectors and a control panel release the agent through an electrical actuator, such as the Honeywell 24 V DC electric control head, and the Ceasefire SQRS has a battery backup for 24 hours.
What is the difference between a clean agent and an inert gas system?
A clean agent such as FK-5-1-12 or HFC-227ea is discharged fast, reaching extinguishing levels in 10 seconds or less on the Ceasefire systems. An inert gas system stores nitrogen, argon, CO2 or a blend in high pressure cylinders and puts the fire out by lowering the oxygen in the room; Honeywell IG-541, for example, brings it down from 20.9% to between 10% and 14.2%.
Is a clean agent safe for electronics?
Ceasefire and Kanex describe their clean agents as electrically non conductive and residue free, so there is no clean up after discharge, and Honeywell describes its FK-5-1-12 agent as safe for PCBs. In a room system the agent can be ventilated out afterwards.
Which systems suit transformers and DG sets?
Kanex CO2 and clean agent indirect systems are listed for dry type transformers and DG sets, and the Ceasefire Auto-Quell watermist range has transformer and generator versions. FPS surveys the equipment and recommends the layout.
Does FPS install and maintain suppression systems, and how do I get a price?
FPS supplies, installs and maintains fire suppression systems in Bhopal and across Madhya Pradesh. Prices depend on the enclosure or room and the agent, so they are on request: call or WhatsApp +91 92440 89060.

Need a Fire NOC or renewal in Madhya Pradesh?

We handle your complete Fire NOC application and renewal: documentation, liaison with the MP Fire Department and compliance support.

Talk to our NOC team
Call +91 92440 89060Send a text messageEmail usWhatsApp us