ISO 9001:2015 Certified · MSME Registered · Military Engineering Services Registered
Fire Protection System logoFIRE PROTECTION SYSTEMTMFire safety contractors, dealers & distributors · Bhopal, M.P.
EXCELLENCE IN FIRE EXTINGUISHER, FIRE HYDRANT, FIRE ALARM & FIRE SUPPRESSION SYSTEMS
Honeywell HFC-227ea Clean Agent Fire Suppression System (25 and 42 bar)
Honeywell logoDealer for Honeywell

Honeywell HFC-227ea Clean Agent Fire Suppression System (25 and 42 bar)

HFC-227eaClean agent25 and 42 barNitrogen pressurised

A high-pressure clean agent system, super-pressurised with dry nitrogen and discharged as a vapour into the protected area within 10 seconds. It suits occupied areas and critical installations with electrical or electronic fire risks.

  • Super-pressurised with dry nitrogen to 25 bar (360 psi); a 42 bar version is also offered
  • Discharged as a vapour within 10 seconds
  • Zero ozone depletion potential (ODP)
  • Can be used where people are present
  • Suited to electrical and electronic fire risks

Standards and approvals: NFPA 2001, PESO, IS 7285

Sizes: 25 Bar, 42 Bar

Ask price & availability

Download the official Honeywell catalogue (PDF, 17.2 MB)

Specifications

Specifications
Specification25 Bar H1-25-34-00025 Bar H1-25-80-00025 Bar H1-25-120-00025 Bar H1-25-140-00042 Bar
CAPACITY34 L80 L120 L140 L
VALVE (NB)1-1/2” (40NB)2” (50NB)2” (50NB)2” (50NB)
AGENT FILL RANGE (KG.)16.4 TO 38.138.5 TO 89.757.7 TO 134.667.3 TO 157.0
HEIGHT (MM)1118184216421867
DIAMETER (MM)Ø 232Ø 267Ø 356Ø 356
DESCRIPTIONHFC-227EA
OZONE DEPLETION POTENTIAL0.0
GLOBAL WARMING POTENTIAL3220
ATMOSPHERIC LIFETIME (YEARS)31-42 YEARS
SNAP (YES/NO)YES

Specifications as published by Honeywell. Please confirm the exact model with us before ordering.

More Honeywell Fire Suppression Systems

Honeywell IG-541 Inert Gas Fire Suppression System

IG-541Inert gas200 and 300 bar

Sizes: 30 L, 50 L, 80 L, 140 L

An inert gas system that puts out class A, B and C fires by lowering the oxygen level in the room, using a blend of 52% nitrogen, 40% argon and 8% CO2. It comes as a stand-alone system for one space or as a multi-zone system.

View specifications ›

Fire Suppression Systems from other brands

Ceasefire

Ceasefire Atom X Automatic Fire Suppression System, Ceiling Mounted

Total floodingFK or MAP 90Ceiling mounted

Sizes: 2 kg, 5 kg, 10 kg, 15 kg

Pre-engineered, retrofittable suppression system built from ceiling mounted agent containers in 2, 5, 10 and 15 kg, linked to detectors and a control panel. It comes with Fluoroketone (FK) clean agent or ABC powder MAP 90, and all units fire together for total flooding.

View specifications ›
Kanex

Kanex Clean Agent Direct Low Pressure (DLP) Panel and Rack Suppression System

Clean agent FE-36, FK-5-1-12 or FM-200Direct release (DLP)2, 4, 6 kg

Sizes: 2, 4, 6 kg

Pre-engineered clean agent system for electrical cabinets, server racks and wind turbine alternator zones, where the UL listed detection tube both senses the fire and delivers the agent at the source. Available in 2, 4 and 6 kg cylinders with FE-36 (HFC-236fa), FK-5-1-12 or FM-200 (HFC-227ea).

View specifications ›

See all fire suppression systems ›

Ask price