Notifier FSP-951 Intelligent Photoelectric Smoke Detector
An intelligent addressable photoelectric smoke detector with an optical chamber that senses smoke from a wide range of fires, and sensitivity that is programmable and monitored by the panel.

Dealer for NotifierAn advanced multi-criteria detector that combines photoelectric, thermal, infrared and carbon monoxide sensing to give both fire and CO detection.
Standards and approvals: UL/ULC: S1111, CSFM: 7272-0028:0510
| Specification | Details | Details |
|---|---|---|
| Height | 2.7" (69 mm) installed in B200S series sounder base | |
| Diameter | 6.875" (175 mm) installed in B200S series sounder base | |
| Weight | 3.4 oz. (95 g) | |
| Color | White (-IV models are ivory) | |
| Operating Humidity Range | 15% to 90% Relative Humidity, Non- condensing | |
| Operating Temperature Range | 32°F to 100°F (0°C to 38°C) | |
| Air Velocity | 0 to 4000 ft./min. (0 to 1219.2 m/min.) | |
| Operating Voltage Range | 15 to 32 VDC | |
| Operating Current @ 24 VDC | 200 uA (one communication every 5 seconds with green LED blink on communication) | |
| Maximum Alarm Current | 2 mA @ 24 VDC (one communication every 5 seconds with red LED solid on) | |
| Maximum Current | 4.5 mA @ 24 VDC (one communication every 5 seconds with amber LED solid on) | |
| Isolator Load Rating | 0.0063 |
Specifications as published by Notifier. Please confirm the exact model with us before ordering.
An intelligent addressable photoelectric smoke detector with an optical chamber that senses smoke from a wide range of fires, and sensitivity that is programmable and monitored by the panel.
An intelligent photoelectric smoke detector with dual thermistors that add 135°F (57°C) fixed temperature heat sensing in the same head.
An intelligent addressable heat detector that uses a thermistor sensing circuit for 135°F (57°C) fixed temperature detection.
A low-profile intelligent addressable heat detector that responds to a rate of temperature rise of 15°F (8.3°C) per minute.
An intelligent addressable heat detector with a thermistor sensing circuit, factory preset to 190°F (88°C) for high temperature detection.
An intelligent plug-in photoelectric smoke detector with a built-in isolator, for FlashScan systems only.
A battery operated, Wi-Fi enabled photoelectric smoke detector from the IMPACT by Honeywell range. When smoke reaches its alarm threshold it sounds a buzzer, flashes an LED and sends real-time alerts to a smartphone through the IMPACT by Honeywell app.
A battery operated standalone smoke alarm with photoelectric sensing that sounds an alarm and lights a red LED when smoke reaches its threshold. It runs on two AA batteries and also warns of a low battery or a chamber fault.
An S200A plug-in photoelectric smoke detector listed with the DXc and ZXSe panels. Its detection chamber is designed to cut false alarms from dust, insects and other debris.
An S200A multi-criteria detector that adds 58°C fixed temperature and rate of rise thermal sensing to a photoelectric smoke sensor, for better false alarm immunity and faster response to a wide range of fires.
A white addressable photoelectric smoke detector working on the light scattering principle, with smoothing filters and embedded software to resist unwanted alarms. The 22051EI version has a built-in isolator.
A two sensor detector that adds thermal sensing to the photoelectric smoke chamber for better false alarm immunity and a faster response to a wide range of fires. The 22051TEI version has a built-in isolator.
Try "landing valve", "Apollo call point", "9 kg ABC" or a model code.
No products yet. Tap "Add to quote" on any product, then send the whole list to us in one WhatsApp message.