Notifier INSPIRE Self-Test Detector Series
Notifier logoDealer for Notifier

Notifier INSPIRE Self-Test Detector Series

INSPIRESelf-TestAddressableUL 268FM approved

Detectors that carry out their own smoke and heat maintenance tests, without canned smoke or heat guns, when used with a compatible panel and the Self-Test app.

  • Releases small amounts of smoke and heat into the chamber to test the sensors
  • Checks automatically whether the dust cover is blocking smoke entry
  • Covers functional test, smoke entry test and visual inspection check
  • Listed to UL 268 7th edition and/or UL 521
  • Two-wire SLC connection, rotary decimal addressing, 15 to 32 volts DC
  • UL listed and FM approved, CSFM listed

Standards and approvals: UL Listed: S1115 (FSP-951-SELFT, FSP-951T-SELFT), S747, FM Approved, CSFM: 7270-0028:0502 (FST-951-SELFT), 7272-0028:0503

Ask price & availability

Specifications

Specifications
SpecificationDetailsDetails
Voltage range15 - 32 volts DC peak
Standby current (max. avg.)200µA @ 24 VDC (one communica- tion every 5 seconds with LED enabled)
Max current4.5 mA @ 24 VDC (“ON”)
Sensitivity• UL Applications:: Open Area: 2.86 - 5.0 %/FT obscuration, Special Application: 0.5 - 2.86 %/FT obscuration
Size2.0" (51mm) high; base determines diameter: B300-6 series: 6.1" (15.6 cm) diameter, B501 series: 4" (10.2 cm) diameter For a complete list of detector bases see DN-60054
Shipping weight3.4 oz. (95 g)
Operating temperature range• FSP-951-SELFT: 32°F to 122°F (0°C to 50°C) • FSP-951T-SELFT: 32°F to 115°F(0°C to 47°C) • FST-951-SELFT:, Set for fixed-temperature or rate-of-rise (ROR):-4°F to 100°F (-20°C to 38°C), Set for high-heat:, 4°F to 150°F (-20°C to 66°C)
UL Listed Velocity Range0-4000 ft/min. (1219.2 m/min.). Velocity range with Self-Test process in operation: 0-300 ft/min (91.4 m/min).
Relative humidity10% to 93% non-condensing
Thermal ratingsfixed-temperature set point 135°F (57°C), rate-of- rise detection 15°F (8.3°C) per minute, high temperature heat 190°F (88°C)
Self-Test OperationThe Self-Test feature offers up to 150 tests before reaching an end of life.
MountingTo ensure the operation of the Self-Test feature, a detec- tor installed on the ceiling must remain in a ceiling-oriented position; those installed on the wall must remain in a wall-oriented position.
Detector Spacing and ApplicationsNOTIFIER recommends spacing detectors in compliance with NFPA 72. For specific informa- tion regarding detector spacing, placement, and special applications refer to NFPA 72. A System Smoke Detector Application Guide, doc- ument SPAG91, is available at www.systemsensor.com.

Specifications as published by Notifier. Please confirm the exact model with us before ordering.