ISO 9001:2015 Certified · MSME Registered · Military Engineering Services Registered
Fire Protection System logoFIRE PROTECTION SYSTEMTMFire safety contractors, dealers & distributors · Bhopal, M.P.
EXCELLENCE IN FIRE EXTINGUISHER, FIRE HYDRANT, FIRE ALARM & FIRE SUPPRESSION SYSTEMS
Dealer for Agni

Agni FYRLAAST Detector Bases in Bhopal

Agni makes two bases for its FYRLAAST addressable detectors: a standard base and an isolator base that protects the loop against short circuits. Both fit the range's smoke, heat and multi sensor detectors, and FPS, an Agni dealer, supplies and installs them in Bhopal and across Madhya Pradesh.

Where to use Detector Bases

  • Every FYRLAAST smoke, heat or multi sensor detector position
  • Surface mounted ceiling installations
  • Loops that need short circuit isolation (isolator base)
  • Long loops in large buildings
  • Hospitals and hotels
  • Offices and commercial buildings
  • Factories and warehouses

Agni Detector Bases models

How to choose

Each FYRLAAST detector head fits into a base that is fixed to the ceiling and carries the wiring. The FL-433/SB standard base suits the smoke, heat and multi sensor detectors and is surface mounted.

The FL-433/IB isolator base adds loop protection. It monitors the loop for a short circuit fault, isolates it, and resets itself once the fault is removed. An LED shows its status, and Agni allows up to 70 devices between isolators.

Placing isolator bases at planned points means one cable fault affects only a small part of the loop. FPS plans isolator positions with the loop layout and gives a price on request.

Frequently asked questions

Which detectors fit the Agni FYRLAAST bases?
Both the standard base and the isolator base fit the FYRLAAST smoke, heat and multi sensor detectors.
What does an isolator base do?
It watches the loop for a short circuit, isolates the faulty section so the rest of the loop keeps working, and resets itself once the fault is removed.
How many devices can sit between isolators?
Agni allows up to 70 devices between isolators on a FYRLAAST loop.
Are the bases surface or flush mounted?
Agni lists both the standard base and the isolator base for surface mounting.
Can FPS supply Agni detector bases in Bhopal?
Yes. FPS is an Agni dealer and supplies and installs FYRLAAST detector bases in Bhopal and across Madhya Pradesh. Prices are on request: call or WhatsApp +91 92440 89060.

More Agni products

Call +91 92440 89060Send a text messageEmail usWhatsApp us