ISO 9001:2015 Certified · MSME Registered · Military Engineering Services Registered
Fire Protection System logoFIRE PROTECTION SYSTEMTMFire safety contractors, dealers & distributors · Bhopal, M.P.
EXCELLENCE IN FIRE EXTINGUISHER, FIRE HYDRANT, FIRE ALARM & FIRE SUPPRESSION SYSTEMS
Honeywell HS-81/HS/L Compact Fire and Gas Controller (EN version)
Honeywell logoDealer for Honeywell

Honeywell HS-81/HS/L Compact Fire and Gas Controller (EN version)

HS-81EN versionFire and gasSIL2EN 54-2

The compact EN version of Honeywell's HS-81 fire and gas controller, with a single or double power supply, for industrial sites where space is tight. It handles flame, gas and smoke detection, logic control, extinguishing release and alarm outputs from one panel.

  • Hot backup redundant CPUs, with hot-swappable CPUs, power supplies and cards
  • Automatic testing of card inputs and outputs, with self-diagnostics and fault signalling
  • Malfunctioning cards are disabled safely and automatically
  • Redundant, looped panel communication bus
  • Redundant cards for fire and gas duties; works with multi-protocol addressable detection
  • Listed standards include EN 54-2, EN 54-4, EN 12094, SIL2 (IEC 61508) and ATEX

Standards and approvals: SIL2, ATEX, EN12094, EN54-2, EN54-4, IEC61508

Ask price & availability

Download the official Honeywell catalogue (PDF, 17.2 MB)

Specifications

Specifications
SpecificationDetailsDetailsDetailsDetails
Input power110-240 VAC (± 10%)
Nominal output power24VDC
Maximum output power4A/8A (dual supply version)
Cabinetsheetmetal with internal door and transparent outer door; stainless steel option available upon request
ColorRAL 7035 (Industrial Gray standard), RAL 3000 (Red for fire, optional)
Protection degreeCabinet rated for IP54/IP66
Installationwall mounting
Size27.5” (700mm) x 19.7” (500mm) x 9.8” (250mm)
Maximum batteries charging current4A, up to 65Ah. | Up to 14Ah allowed inside cabinet. Larger batteries require use of a separate cabinet
Protectionssurge, short-circuit and reverse battery
Applicable Safety categoryUp to SIL2
RedundancyCPU and Power Supply
IO Card Capacity08 nos. (Max)
Max Humidity0-95% non condensing
HS81-HS/L-SingleEN Compact panel 8 slots, Double CPU, Single Power supply
HS81-HS/L-DoubleEN Compact panel 8 slots Double CPU, Double Power supply
HS81-HS/L-Single-REN Compact 8 slots, Dbl CPU, Single supp - Red cab
HS81-HS/L-Double-REN Compact 8 slots, Dbl CPU, Single supp - Red cab
HS81-HS/M-SingleMarine Compact panel 8 slots Double CPU, Single Power supply
HS81-HS/M-Single-RMarine Compact 8 slots 2 CPU, 1 supply - Red cab

Specifications as published by Honeywell. Please confirm the exact model with us before ordering.

More Honeywell Fire Alarm Control Panels

Fire Alarm Control Panels from other brands

See all fire alarm control panels ›

Ask price
Call +91 92440 89060Send a text messageEmail usWhatsApp us