Siemens XC3610-AA Cerberus PRO Fire and Extinguishing Control Panel, 1 Loop, FDnet (Sinteso Devices)
The XC360 series single-sector panel for Sinteso peripherals over FDnet, with detection and alarm for up to 126 addressable devices on one loop.

Dealer for SiemensA compact XC360 series panel for one extinguishing sector, handling detection, evaluation and alarm for up to 126 addressable devices from the Cerberus FIT and Cerberus PRO ranges over C-NET.
Standards and approvals: EN 54-2, EN 54-4, LPCB
| Specification | XC361-ZA |
|---|---|
| Detector compatibility | See A6V13866363, List of compatibility |
| Standard | EN 54-2 , EN 54-4 , EN 12094-1 |
| Number of addresses | 126 |
| Number of detector lines | 1 loop, 2 stubs |
| Power consumption | 108 VA |
| Supervised output | 2x Horn |
| Mains voltage | AC 196…253 V |
| Number of loops | 1 |
| Operating voltage | AC 196…253 V, 230 V |
| Operating current | 600 mA |
| Bypass time for emergency power supply | 72 h |
| Battery capacity | 25 V/Ah |
| Installation height | 1.6 to 1.7 m |
| Operating temperature | -5…40 °C |
| Storage temperature | -20…+60 °C |
| Relative humidity | ≤95 % rel. |
| Protection category | IP30 |
| Relay outputs | 2-position |
| Color | Signal white, ~RAL 9003 |
| Color housing/cover | Signal white, RAL 9003 / Signal white, RAL 9003 |
| Event memory | max. 2000 events |
| Battery | BAT12-25 |
| Digital inputs/outputs | The mainboard has 4 configurable inputs/outputs. Each can be configured as an input or output. |
| Input voltage | AC 230 V |
| Weight (net) | 7.18 kg (without battery) kg |
Specifications as published by Siemens. Please confirm the exact model with us before ordering.
The XC360 series single-sector panel for Sinteso peripherals over FDnet, with detection and alarm for up to 126 addressable devices on one loop.
The 19 inch rack variant of the XC1001-A for complex multi-sector extinguishing installations, with up to 16 panels in one housing.
A Sinteso 4-loop fire control panel with extinguishing control and an integrated operating unit for up to 504 addresses, in a Large housing with FBA terminal.
A remote extinguishing terminal for one sector, used as the primary terminal for the FC2040-CL or as an extra terminal.
A module bus card that adds single-sector or multi-sector extinguishing control to FC2020 and FC2040 panels in Comfort or Large housings.
Conventional control panel for gas suppression, with 3 detection zones and 1 extinguishing zone that can drive solenoid or Metron actuators. A large LCD countdown timer shows the time to release.
Abort switch for extinguishing systems, compatible with the Rapid-Sense control panel and complying with BS 7273-1 requirements.
A microprocessor based 2 zone panel that detects a fire and releases a gaseous agent, with main and standby cylinder output and several release options.
A microprocessor based 4 zone agent release panel with two release circuits and solenoid coil monitoring, which Ravel states is UL listed.
Microprocessor based panel that controls a gas flooding suppression system, with single or cross zone logic, a pre discharge warning and a 24 VDC gas release output. It includes programmable countdowns, manual abort and false release protection.
Try "landing valve", "Apollo call point", "9 kg ABC" or a model code.