Morley by Honeywell HM/PSE/S2 Photoelectric Smoke Detector (DXc and ZXSe)
An S200A plug-in photoelectric smoke detector listed with the DXc and ZXSe panels. Its detection chamber is designed to cut false alarms from dust, insects and other debris.

Dealer for Morley by HoneywellAn addressable high heat detector for the Morley UL range, UL listed with the B300-6-IV base, with an operating temperature range of -20°C to 66°C.
Standards and approvals: UL Listing: S36217
Download the official Morley by Honeywell catalogue (PDF, 2.3 MB)
| Specification | HM/HTSE/UL/W |
|---|---|
| Shipping weight | 3.4 oz. (95 g) |
| Operating temperature range | HM-HTSE-UL-W:, 4°F to 150°F (-20°C to 66°C) |
| Detector spacing | UL approved for 50 ft. (15.24 m) center-to-center |
| Relative humidity | 10% to 93% non-condensing |
| Voltage range | 15 - 32 volts DC peak |
| Standby current (max. avg.) | 200μA @ 24 VDC (one communication every 5 seconds with LED enabled) |
| Max current | 4.5 mA @ 24 VDC (“ON”) |
Specifications as published by Morley by Honeywell. Please confirm the exact model with us before ordering.
An S200A plug-in photoelectric smoke detector listed with the DXc and ZXSe panels. Its detection chamber is designed to cut false alarms from dust, insects and other debris.
An S200A multi-criteria detector that adds 58°C fixed temperature and rate of rise thermal sensing to a photoelectric smoke sensor, for better false alarm immunity and faster response to a wide range of fires.
A plug-in addressable heat detector with a single thermistor sensing circuit, giving fixed 58°C and rate of rise (10°C per minute) detection to EN 54-5 Class A1R.
A plug-in addressable heat detector with a single thermistor sensing circuit that alarms at a fixed 58°C, to EN 54-5 Class A1S.
A Morley-IAS thermal sensor listed with the DXc and ZXSe panels. The datasheet linked on the maker's page is for other model numbers, so FPS confirms the details of this part before supply.
A multi-criteria, multi-sensor detector that combines photoelectric smoke, thermal and infra red sensing, listed with the DXc and ZXSe panels. The maker presents PTIR as an alternative to ionisation detectors with better false alarm immunity.
A battery operated, Wi-Fi enabled photoelectric smoke detector from the IMPACT by Honeywell range. When smoke reaches its alarm threshold it sounds a buzzer, flashes an LED and sends real-time alerts to a smartphone through the IMPACT by Honeywell app.
A battery operated standalone smoke alarm with photoelectric sensing that sounds an alarm and lights a red LED when smoke reaches its threshold. It runs on two AA batteries and also warns of a low battery or a chamber fault.
An intelligent addressable photoelectric smoke detector with an optical chamber that senses smoke from a wide range of fires, and sensitivity that is programmable and monitored by the panel.
An intelligent photoelectric smoke detector with dual thermistors that add 135°F (57°C) fixed temperature heat sensing in the same head.
A white addressable photoelectric smoke detector working on the light scattering principle, with smoothing filters and embedded software to resist unwanted alarms. The 22051EI version has a built-in isolator.
A two sensor detector that adds thermal sensing to the photoelectric smoke chamber for better false alarm immunity and a faster response to a wide range of fires. The 22051TEI version has a built-in isolator.