System Sensor ECO1003A Conventional Photoelectric Smoke Detector (ECO1000)
A low profile conventional photoelectric smoke detector with an optical chamber and an ASIC for quick, accurate detection, designed to extend the interval between cleanings.

A low profile conventional heat detector tested to EN 54-5 Class A2R, supplied with its base in the pack.
Standards and approvals: CE, EN54-5:2017+A1:2018 Class A2R
| Specification | HSE/CE |
|---|---|
| Operating Voltage Range | 8 to 30VDC (Nominal 12/24VDC), Non-Polarised |
| Humidity | 5 to 95% Relative Humidity (non condensing) |
| Height | 53mm (Including base) |
| Diameter | 99mm (detector only), 103mm (including base) |
| Weight | 91g (including base) |
| Max Wire Gauge for Terminals | 0.75mm 2 to 2.5mm2 |
| Color | White LC-FY2605 |
| Material | ABS15A1 |
Specifications as published by System Sensor. Please confirm the exact model with us before ordering.
A low profile conventional photoelectric smoke detector with an optical chamber and an ASIC for quick, accurate detection, designed to extend the interval between cleanings.
A multi-criteria conventional detector that combines an optical chamber and a thermal element with a microprocessor, for a faster response to real fires and fewer environmental false alarms.
Three conventional heat detectors covering 58°C and 78°C fixed temperature and rate of rise, for small to medium systems such as small industrial units, retail units and guest houses.
A Series 300 photoelectric smoke detector that works on a conventional zone but adds intelligent maintenance features through a hand-held tool.
A Series 300 photo-thermal detector whose on-board processor only signals an alarm once it is satisfied that a fire has started, reducing nuisance alarms while improving response.
Three Series 300 heat detectors: 58°C fixed temperature (5351TE), 78°C fixed temperature (4351EA) and rate of rise (5351EA), with a latching LED and an optional remote LED annunciator.
A battery operated, Wi-Fi enabled photoelectric smoke detector from the IMPACT by Honeywell range. When smoke reaches its alarm threshold it sounds a buzzer, flashes an LED and sends real-time alerts to a smartphone through the IMPACT by Honeywell app.
A battery operated standalone smoke alarm with photoelectric sensing that sounds an alarm and lights a red LED when smoke reaches its threshold. It runs on two AA batteries and also warns of a low battery or a chamber fault.
An intelligent addressable photoelectric smoke detector with an optical chamber that senses smoke from a wide range of fires, and sensitivity that is programmable and monitored by the panel.
An intelligent photoelectric smoke detector with dual thermistors that add 135°F (57°C) fixed temperature heat sensing in the same head.
An S200A plug-in photoelectric smoke detector listed with the DXc and ZXSe panels. Its detection chamber is designed to cut false alarms from dust, insects and other debris.
An S200A multi-criteria detector that adds 58°C fixed temperature and rate of rise thermal sensing to a photoelectric smoke sensor, for better false alarm immunity and faster response to a wide range of fires.