System Sensor ECO1003A Conventional Photoelectric Smoke Detector (ECO1000)
A low profile conventional photoelectric smoke detector with an optical chamber and an ASIC for quick, accurate detection, designed to extend the interval between cleanings.

An intrinsically safe conventional photoelectric smoke detector for open area protection, used with 2-wire control panels through an interface module.
| Specification | JTY-GD-2151EIS |
|---|---|
| Dimension: | 104mm(Diameter, JTY-GD-2151EIS/JTWB-BCD-5151EIS) |
| Height: | 51mm(JTY-GD-2151EIS, JTWB-BCD-5151EIS) |
| Weight: | 88g(JTY-GD-2151EIS), 80g(JTWB-BCD-5151EIS) |
| Input Voltage: | 8.5 to 28VDC(JTY-GD-2151EIS), 8.5 to 28VDC(JTWB-BCD-5151EIS) |
| Installation Temperature: | -10℃ to 55℃(JTY-GD-2151EIS), -10℃ to 50℃(JTWB-BCD-5151EIS) |
| Operating Humidity Range: | 10% to 95% Relative Humidity ( non-condensing, JTY-GD-2151EIS/JTWB-BCD-5151EIS) |
| Latching Alarm: | Reset by momentary power interruption |
| Sensitivity: | 63℃ fixed or 10℃/min rate-of-rise(JTWB-BCD-5151EIS) |
| Intrinsic Safety Rating: | Exia II CT6 (JTY-GD-2151EIS, JTWB-BCD-5151EIS) |
Specifications as published by System Sensor. Please confirm the exact model with us before ordering.
A low profile conventional photoelectric smoke detector with an optical chamber and an ASIC for quick, accurate detection, designed to extend the interval between cleanings.
A multi-criteria conventional detector that combines an optical chamber and a thermal element with a microprocessor, for a faster response to real fires and fewer environmental false alarms.
Three conventional heat detectors covering 58°C and 78°C fixed temperature and rate of rise, for small to medium systems such as small industrial units, retail units and guest houses.
A Series 300 photoelectric smoke detector that works on a conventional zone but adds intelligent maintenance features through a hand-held tool.
A Series 300 photo-thermal detector whose on-board processor only signals an alarm once it is satisfied that a fire has started, reducing nuisance alarms while improving response.
Three Series 300 heat detectors: 58°C fixed temperature (5351TE), 78°C fixed temperature (4351EA) and rate of rise (5351EA), with a latching LED and an optional remote LED annunciator.
A battery operated, Wi-Fi enabled photoelectric smoke detector from the IMPACT by Honeywell range. When smoke reaches its alarm threshold it sounds a buzzer, flashes an LED and sends real-time alerts to a smartphone through the IMPACT by Honeywell app.
A battery operated standalone smoke alarm with photoelectric sensing that sounds an alarm and lights a red LED when smoke reaches its threshold. It runs on two AA batteries and also warns of a low battery or a chamber fault.
An intelligent addressable photoelectric smoke detector with an optical chamber that senses smoke from a wide range of fires, and sensitivity that is programmable and monitored by the panel.
An intelligent photoelectric smoke detector with dual thermistors that add 135°F (57°C) fixed temperature heat sensing in the same head.
An S200A plug-in photoelectric smoke detector listed with the DXc and ZXSe panels. Its detection chamber is designed to cut false alarms from dust, insects and other debris.
An S200A multi-criteria detector that adds 58°C fixed temperature and rate of rise thermal sensing to a photoelectric smoke sensor, for better false alarm immunity and faster response to a wide range of fires.
Try "landing valve", "Apollo call point", "9 kg ABC" or a model code.