ISO 9001:2015 Certified · MSME Registered · Military Engineering Services Registered
Fire Protection System logoFIRE PROTECTION SYSTEMTMFire safety contractors, dealers & distributors · Bhopal, M.P.
EXCELLENCE IN FIRE EXTINGUISHER, FIRE HYDRANT, FIRE ALARM & FIRE SUPPRESSION SYSTEMS

Water Curtain and Drencher System in Bhopal

A water curtain, or drencher, puts a sheet of water across an opening so that fire and heat cannot pass through it. It is used where a fire wall cannot be built: large openings between floors, escalators, rolling shutters, windows close to another building, and gaps between plant. FPS designs, supplies, installs and maintains water curtain systems in Bhopal and across Madhya Pradesh, with nozzles from Tyco, HD Fire, Kartar Valves and Aaag.

Also called
drencher system, drencher sprinkler system, water curtain sprinkler system, window drenchers, water screen, exposure protection system
Used for
Escalator and stair openings, rolling shutters, glazed facades and windows, gaps between buildings, atriums and stages
Brands
Tyco, HD Fire, Kartar Valves, Aaag
Supplied by
Fire Protection System, Bhopal (supplier for Tyco and Aaag; dealer for HD Fire; authorised distributor for Kartar Valves), across Madhya Pradesh
Price
On request: WhatsApp or call +91 92440 89060

Which one do you need?

Large openings, shutters and escalatorsCurtain nozzles
Windows and glazingWindow sprinklers
Separating plant or buildingsJumbo curtain nozzle
The valve that releases itDeluge valves

How a water curtain works

Open curtain nozzles are set in a line along the top or bottom of the opening. Their deflectors spread the water flat, in a semicircular sheet, so the nozzles overlap into a continuous curtain. The water takes up and reflects radiant heat, cools the smoke and wets the surfaces on the protected side.

The nozzles are fed through a deluge valve, opened automatically by the fire alarm or by heat detectors near the opening, or by hand. Window sprinklers do a similar job on glazing: closed heads on the sprinkler system wet the whole glass so it holds back the fire, and open exposure sprinklers spray the outside of windows that face another building.

In India these systems are often called drenchers. A curtain on its own does not stop smoke, so it is planned together with the building's smoke control and fire alarm.

  • Escalator and stair openings
  • Rolling shutters and fire doors
  • Glazed facades and windows
  • Gaps between buildings
  • Atriums and stages
  • Separation between plant areas

Water curtain nozzles

Aaag curtain nozzles in brass or stainless steel spread a flat semicircular curtain, K 23 to 72, for up to 10 bar, pendent over windows or horizontal to divide an area. HD Fire CN and CNS nozzles are UL Listed in K20 to K79, and its stainless steel JCS jumbo nozzle throws a large curtain upward from a flanged end. Kartar makes brass curtain nozzles in heavy and medium versions.

ModelKey facts
HD Fire Jumbo Water Curtain Nozzle JCS, Stainless Steel, FlangedWater curtain, Model JCS, Stainless steel, Flanged
HD Fire Water Curtain Nozzle, Models CN and CNS, UL ListedWater curtain, ½ inch, K20 to K79, UL Listed
Kartar Valves Water Curtain Nozzle, Brass, 1/2 inch BSP (Heavy and Medium)Water curtain, Brass, 1/2 inch BSP
Aaag Water Curtain Spray Nozzle, Brass (AAAG 291CB)Water curtain, Brass, 10 bar, K 23 to 72
Aaag Water Curtain Spray Nozzle, Stainless Steel (AAAG 291CS)Water curtain, Stainless steel, 10 bar, K 23 to 72

Window and exposure sprinklers

Tyco WS and CWS window sprinklers are closed, fast response heads listed to wet the whole surface of tempered, heat strengthened or ceramic glass windows, the CWS hidden behind a cover plate. Tyco Issue A and B exposure sprinklers spray the outside of a building's windows against a fire next door.

ModelKey facts
Tyco Model WS Specific Application Window Sprinkler, Horizontal and Pendent Vertical Sidewall, K5.6 (TFP620)Window sprinkler, Fast response, glass bulb, K5.6, Brass
Tyco Model CWS Concealed Window Sprinkler, Pendent Vertical Sidewall, K5.6 (TFP621)Concealed window sprinkler, Fast response, solder link, K5.6, Brass
Tyco Issue A and B Window Type Exposure Protection Sprinklers (TFP835)Exposure protection, Window sprinklers, Bronze, UL, FM

Deluge valves and release

Each curtain is fed through a deluge valve, opened by the fire alarm, heat detectors or a manual release beside the opening. The deluge system page compares the valves, skids and trim we supply.

Deluge valves, skids and trim ›

How to choose

Start with the opening: its width and height set the number of nozzles and their spacing, and the K factor and pressure set the water each one gives. The curtain must cover the full width, with overlap at the ends.

Decide the release: automatic from the fire alarm or heat detectors next to the opening, with a manual release beside it, through one deluge valve per curtain or zone.

Plan the water: all the nozzles of a curtain flow at once, so the pumps and tank are sized for every curtain that can operate together. We survey, design, install and test the system, and maintain it under an AMC.

Frequently asked questions

What is a drencher system?
Another name for a water curtain system: open nozzles fed through a deluge valve that put a sheet of water across an opening, window or gap to stop fire and heat spreading through it.
Where are water curtains used?
Where a fire wall or fire door cannot close an opening: escalators and stair openings between floors, rolling shutters, glazed walls and windows close to another building, stages, and gaps between buildings or plant.
What is a water curtain nozzle?
An open nozzle with a deflector that spreads water flat in a semicircular sheet instead of a cone, so a line of them forms a continuous curtain. Aaag, HD Fire and Kartar make them in brass or stainless steel.
Does a water curtain stop smoke?
Not on its own. It cools the smoke and blocks radiant heat, but smoke can still pass, so it is planned with the building's smoke control and fire alarm.
How much does a water curtain system cost?
It depends on the hazard, the number of zones, the valves, the nozzles or heads and the water supply, so we quote after a free site survey. Send the size of each opening and how many there are on WhatsApp at +91 92440 89060. Every supply is billed on a GST invoice.

Need a Fire NOC or renewal in Madhya Pradesh?

We handle your complete Fire NOC application and renewal: documentation, liaison with the MP Fire Department and compliance support.

Talk to our NOC team
Call +91 92440 89060Send a text messageEmail usWhatsApp us