Notifier AMPS-24/E Addressable Power Supply and Battery Charger
An addressable power supply and battery charger with up to three 24 VDC outputs, for the NFS-3030 and NFS2-3030 panels, that can also be the primary supply for the NCA-2 annunciator.
Fire Protection System (FPS), a Notifier dealer in Bhopal, supplies Notifier addressable power supplies and battery chargers (AMPS-24/E, ACPS-610(E) and the INSPIRE PMB AUX Series) and the LCM-320 and LEM-320 loop modules for ONYX panels. FPS installs, tests and services them across Madhya Pradesh.
An addressable power supply and battery charger with up to three 24 VDC outputs, for the NFS-3030 and NFS2-3030 panels, that can also be the primary supply for the NCA-2 annunciator.
An auxiliary power supply with a battery charging option, giving 6 amps of shared power to four outputs while charging batteries, or 10 amps with an external charger.
An addressable power supply for INSPIRE N16 panels with four power-limited NAC outputs, two 24 VDC auxiliary outputs and a remote sync input.
A plug-in loop control module that adds signalling line circuits to ONYX NFS2-640 and NFS2-3030 fire alarm control panels.
A loop expander module listed together with the LCM-320, with FDNY certificates for use with the NFS2-640 and NFS2-3030 panels.
Fire alarm systems often need power beyond what the main panel provides, for sounders, strobes and other devices on notification appliance circuits (NAC). Notifier's addressable power supplies sit on the system like other devices, so the panel can monitor them.
The AMPS-24/E is an addressable power supply and battery charger with up to three 24 VDC outputs, working in FlashScan or CLIP (Classic Loop Interface Protocol) mode with the NFS-3030 and NFS2-3030; it can also be the primary supply for the NCA-2 annunciator. The ACPS-610(E) is an auxiliary supply that gives 6 amps of shared power to four outputs while charging batteries from 12 to 200 AH, or 10 amps when used with an external charger.
For INSPIRE N16 panels, the PMB AUX Series is addressable on the CLP bus and gives four power-limited NAC outputs for Class A or Class B wiring, two 24 VDC auxiliary outputs and 6 amps in standby or 8.5 amps in alarm. Up to two can be fitted in an N16x series panel or compatible enclosure.
To add signalling line circuits to ONYX NFS2-640 and NFS2-3030 panels, use the LCM-320 loop control module, which runs up to 12,500 feet (3,810 m) on a Class B SLC loop and has a built-in degraded mode. The LEM-320 loop expander module is listed alongside it for the same panels. FPS supplies, installs and services all of these in Bhopal and across Madhya Pradesh.