Notifier FCM-1 Addressable Control Module
An intelligent addressable control module that supervises wiring to devices powered from an external supply, such as horns, strobes or bells, with Class A or Class B supervision.
Fire Protection System (FPS), a Notifier dealer in Bhopal, supplies Notifier intelligent addressable modules: monitor, zone, dual monitor, control, relay, releasing, firefighter phone, analogue 4 to 20 mA input and fault isolator modules, plus the INSPIRE TM-8 transmitter module. FPS installs, programs and maintains them across Madhya Pradesh.
An intelligent addressable control module that supervises wiring to devices powered from an external supply, such as horns, strobes or bells, with Class A or Class B supervision.
An addressable relay module giving a dry-contact output to switch auxiliary devices such as fans, dampers and control equipment, using one of 159 module addresses on the SLC loop.
A module that lets the fire alarm panel monitor and control a circuit of up to two firefighter phones and connect remote phones to a central telephone console.
An intelligent monitor module that supervises a circuit of dry-contact devices, such as conventional heat detectors and pull stations, or monitors and powers a circuit of two-wire smoke detectors.
A standard-sized zone module that monitors and supervises compatible two-wire, 24 volt smoke detectors on a Style D (Class A) or Style B (Class B) circuit and reports the zone to the panel.
A dual monitor module that gives two independent two-wire initiating device circuits at two consecutive addresses, for fire alarm, supervisory or security contacts.
A small intelligent monitor module that fits inside devices or junction boxes, supervising dry-contact devices or monitoring and powering two-wire smoke detectors.
An addressable module for two-wire loops that combines two relay outputs for Form C switching with two Class B monitor inputs for normally open contacts.
An addressable analogue input module that lets the NFS2-3030 panel monitor and display readings from linear-scale 4 to 20 mA sensors, such as gas, temperature and air speed sensors.
A releasing control module with a redundant protocol: it must be armed and then confirmed within a 3 second window before it activates, and it supervises the solenoid wiring.
An addressable isolator module that protects the fire alarm system against wire-to-wire short circuits on the SLC loops.
An INSPIRE module that gives either remote station service with three reverse-polarity outputs (alarm, trouble and supervisory) or one fire municipal box trip, designed to meet NFPA 72.
An addressable module connects a device that has no address of its own, such as a switch, a relay or a circuit of conventional detectors, to the SLC loop (signalling line circuit) of a Notifier intelligent panel, so the panel can identify, monitor or control it. Most of these modules set their address with rotary switches, from 01 to 159 in FlashScan mode, Notifier's high speed loop protocol.
For inputs, choose a monitor module. The FMM-1 supervises a circuit of dry-contact devices, such as conventional heat detectors and pull stations, with Class A wiring, and the FMM-101 is a smaller Class B version that fits inside devices or junction boxes. The FZM-1 monitors and powers one zone of two-wire, 24 volt smoke detectors. The FDM-1 gives two independent Class B input circuits at two consecutive addresses, and the FDRM-1 combines two relays with two Class B monitor inputs. The FMM-4-20 lets the NFS2-3030 panel read industry-standard 4 to 20 mA sensors.
For outputs, the FCM-1 control module supervises wiring to devices such as horns, strobes or bells that take power from an external supply, with Class A or Class B supervision, while the FRM-1 gives a dry-contact output for fans, dampers and control equipment. The FCM-1-REL releasing module uses a redundant protocol: it must be armed and then confirmed within a 3 second window before it operates, and it can drive one 24 V or two 12 V solenoids. The FTM-1 monitors and controls a circuit of up to two firefighter phones.
Add ISO-X fault isolator modules to protect the loop: when a short circuit occurs, part of the loop keeps working, and the module resets itself once the short is cleared. On INSPIRE systems, the TM-8 provides remote station outputs or a municipal box trip. FPS supplies, installs, programs and maintains Notifier modules in Bhopal and across Madhya Pradesh.