ISO 9001:2015 Certified · MSME Registered · Military Engineering Services Registered
Fire Protection System logoFIRE PROTECTION SYSTEMTMFire safety contractors, dealers & distributors · Bhopal, M.P.
EXCELLENCE IN FIRE EXTINGUISHER, FIRE HYDRANT, FIRE ALARM & FIRE SUPPRESSION SYSTEMS
Notifier FMM-101 Mini Monitor Module
Notifier logoDealer for Notifier

Notifier FMM-101 Mini Monitor Module

Mini monitor moduleClass BCompactFM approved

A small intelligent monitor module that fits inside devices or junction boxes, supervising dry-contact devices or monitoring and powering two-wire smoke detectors.

  • Smaller size fits inside devices or junction boxes
  • Class B supervised wiring to the monitored device
  • Direct-dial address entry, 01 to 159
  • 15 to 32 VDC, 11 V maximum circuit voltage
  • 0°C to 49°C, 10% to 93% humidity non-condensing
  • UL and ULC listed, FM approved, with CSFM, MEA and FDNY listings

Standards and approvals: UL: S635, ULC: S635, FM Approved, CSFM: 7300-0028:0219, MEA: 457-99-E, FDNY: COA #6038 (NFS2-640, NFS-320), COA# 6058

Ask price & availability

Specifications

Specifications
SpecificationFMM-101
Nominal operating voltage15 to 32 VDC.
Average operating current350 μA, 1 communication every 5 seconds, 47k EOL; 600 μA Max. (Communicating, IDC Shorted).
Maximum IDC wiring resistance40 ohms.
Maximum IDC Voltage11 Volts.
Maximum IDC Current400 μA.
EOL resistance47K ohms.
Temperature range32°F to 120°F (0°C to 49°C).
Humidity range10% to 93% noncondensing.
Dimensions1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep.
Wire length6" (15.24 cm) minimum.
Direct-dial entry of address01 to 159 on FlashScan loops, 01 to 99 on CLIP loops.

Specifications as published by Notifier. Please confirm the exact model with us before ordering.

More Notifier Interfaces & Modules

Notifier FZM-1 Zone Interface Module

Zone moduleTwo-wire detectorsClass A or B

A standard-sized zone module that monitors and supervises compatible two-wire, 24 volt smoke detectors on a Style D (Class A) or Style B (Class B) circuit and reports the zone to the panel.

View specifications ›

Fire Alarm Interfaces and Modules from other brands

Apollo

Apollo Intelligent Input/Output Module

SA4700-102APOInput/OutputXP95, Discovery, CoreProtocol

A loop device that monitors single pole, volt-free contact inputs and controls relay output contacts, linking the fire panel to other equipment. It works with XP95, Discovery and CoreProtocol.

View specifications ›

See all fire alarm interfaces and modules ›

Ask price
Call +91 92440 89060Send a text messageEmail usWhatsApp us