Notifier FTM-1 Firephone Control Module
Notifier logoDealer for Notifier

Notifier FTM-1 Firephone Control Module

Firefighter telephoneControl moduleFlashScanFM approved

A module that lets the fire alarm panel monitor and control a circuit of up to two firefighter phones and connect remote phones to a central telephone console.

  • Monitors and controls up to two firefighter phones
  • Tells apart normal, off-hook and trouble conditions
  • Two pairs of output terminals for fault-tolerant Style Z wiring
  • Powered directly by the two-wire SLC loop, address 01 to 159 in FlashScan
  • 15 to 32 VDC, 0°C to 49°C
  • UL listed and FM approved, ULC listed as FTM-1A, with CSFM and FDNY listings

Standards and approvals: UL Listed: S635, ULC Listed: S635 (FTM-1A), FM Approved, CSFM: 7300-1653:0182, 7165-0028:0224, 7165- 0028:0243, FDNY: COA #6065, #6067

Ask price & availability

Specifications

Specifications
SpecificationDetails
Normal operating voltage15 to 32 VDC.
Maximum current draw7.5 mA (LED on).
Average operating current7.5 mA group poll (FlashScan® mode) with LED flashing.
External supply voltage (between Terminals T3 and T4)maximum 28 VDC.
EOL resistance3.9K ohms.
Temperature range32°F to 120°F (0°C to 49°C).
Humidity range10% to 93% non-condensing.
Dimensions4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box.
Weight6.3 oz.

Specifications as published by Notifier. Please confirm the exact model with us before ordering.

More Notifier Interfaces & Modules

Notifier FZM-1 Zone Interface Module

Zone moduleTwo-wire detectorsClass A or B

A standard-sized zone module that monitors and supervises compatible two-wire, 24 volt smoke detectors on a Style D (Class A) or Style B (Class B) circuit and reports the zone to the panel.

View specifications ›

Fire Alarm Interfaces and Modules from other brands

Apollo

Apollo Intelligent Input/Output Module

SA4700-102APOInput/OutputXP95, Discovery, CoreProtocol

A loop device that monitors single pole, volt-free contact inputs and controls relay output contacts, linking the fire panel to other equipment. It works with XP95, Discovery and CoreProtocol.

View specifications ›

See all fire alarm interfaces and modules ›

Ask price
Call +91 92440 89060Send a text messageEmail usWhatsApp us