Notifier FMM-1 Addressable Monitor Module
Notifier logoDealer for Notifier

Notifier FMM-1 Addressable Monitor Module

Monitor moduleClass AAddressableUL/ULC listedFM approved

An intelligent monitor module that supervises a circuit of dry-contact devices, such as conventional heat detectors and pull stations, or monitors and powers a circuit of two-wire smoke detectors.

  • Class A supervised wiring to the monitored device
  • Built-in type identification as a monitor module
  • Direct-dial address entry, 01 to 159
  • LED shows normal or off-normal state
  • 15 to 32 VDC, 0°C to 49°C
  • UL and ULC listed, FM approved, with CSFM, MEA and FDNY listings

Standards and approvals: UL: S635, ULC: S635, FM Approved, CSFM: 7300-0028:0219, MEA: 457-99-E, FDNY: COA #6038 (NFS2-640, NFS-320), COA# 6058

Ask price & availability

Specifications

Specifications
SpecificationFMM-1
Nominal operating voltage15 to 32 VDC.
Maximum current draw5.0 mA (LED on).
Average operating current350 μA (LED flashing), 1 com- munication every 5 seconds, 47k EOL.
Maximum IDC wiring resistance40 ohms.
EOL resistance47K ohms.
Temperature range32°F to 120°F (0°C to 49°C).
Humidity range10% to 93% noncondensing.
Dimensions4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box.
Direct-dial entry of address01 to 159 on FlashScan loops; 01 to 99 on CLIP loops.

Specifications as published by Notifier. Please confirm the exact model with us before ordering.

More Notifier Interfaces & Modules

Notifier FZM-1 Zone Interface Module

Zone moduleTwo-wire detectorsClass A or B

A standard-sized zone module that monitors and supervises compatible two-wire, 24 volt smoke detectors on a Style D (Class A) or Style B (Class B) circuit and reports the zone to the panel.

View specifications ›

Fire Alarm Interfaces and Modules from other brands

Apollo

Apollo Intelligent Input/Output Module

SA4700-102APOInput/OutputXP95, Discovery, CoreProtocol

A loop device that monitors single pole, volt-free contact inputs and controls relay output contacts, linking the fire panel to other equipment. It works with XP95, Discovery and CoreProtocol.

View specifications ›

See all fire alarm interfaces and modules ›

Ask price
Call +91 92440 89060Send a text messageEmail usWhatsApp us