ISO 9001:2015 Certified · MSME Registered · Military Engineering Services Registered
Fire Protection System logoFIRE PROTECTION SYSTEMTMFire safety contractors, dealers & distributors · Bhopal, M.P.
EXCELLENCE IN FIRE EXTINGUISHER, FIRE HYDRANT, FIRE ALARM & FIRE SUPPRESSION SYSTEMS
Notifier ISO-X Fault Isolator Module
Notifier logoDealer for Notifier

Notifier ISO-X Fault Isolator Module

Isolator moduleShort circuit protectionSLC loopFM approved

An addressable isolator module that protects the fire alarm system against wire-to-wire short circuits on the SLC loops.

  • Lets part of the loop keep working when a short circuit occurs
  • Resets automatically once the short is corrected
  • SEMS screws with clamping plates for easy wiring
  • 15 to 32 VDC peak, 0°C to 49°C
  • UL and ULC listed, FM approved, with CSFM, MEA, U.S. Coast Guard and Lloyd's Register listings

Standards and approvals: UL: S635 (UOXX); BP6480 (AMCX, APOU), ULC: S635 (OUOXXC, ISO-XA), FM Approved, CSFM: 7165-0028:0214; 7165-0028:0224; 7165- 0028:0243, MEA: 17-96-E; 104-93-E Vol. VI; 290-91-E Vol. V; 317-01- E; 447-99-E, U.S. Coast Guard: 161.002/42/1 (NFS-640); 161.002/50/0, Lloyd’s Register: 11/600013 (NFS2-640/NFS-320/NFS- 320C, excluding B210LP(A)), BSA: 578-81-SA

Ask price & availability

Specifications

Specifications
SpecificationDetails
Normal operating voltage15 to 32 VDC (peak).
Standby current450 μA (not isolating) .
Maximum current draw17 mA (device in isolation, LED latched in alarm).
Temperature range32°F to 120°F (0°C to 49°C).
Relative humidity10% to 93% (non-condensing).
Weight5 oz. (150 grams).
Dimensions4.5”H x 4.5”W x 0.25” D (11.43 cm H x 11.43 cm W x 0.635 cm D).

Specifications as published by Notifier. Please confirm the exact model with us before ordering.

More Notifier Interfaces & Modules

Notifier FZM-1 Zone Interface Module

Zone moduleTwo-wire detectorsClass A or B

A standard-sized zone module that monitors and supervises compatible two-wire, 24 volt smoke detectors on a Style D (Class A) or Style B (Class B) circuit and reports the zone to the panel.

View specifications ›

Fire Alarm Interfaces and Modules from other brands

Apollo

Apollo Intelligent Input/Output Module

SA4700-102APOInput/OutputXP95, Discovery, CoreProtocol

A loop device that monitors single pole, volt-free contact inputs and controls relay output contacts, linking the fire panel to other equipment. It works with XP95, Discovery and CoreProtocol.

View specifications ›

See all fire alarm interfaces and modules ›

Ask price