ABC Trolley Fire Extinguisher, 25 kg to 100 kg, in Bhopal

ABC trolley fire extinguishers carry 25 to 100 kg of powder on wheels with a long hose, for large risks where a portable unit would run out too soon. Here are 20 trolley and wheeled models from Ceasefire, Kanex, Minimax and Balaji Fire Safety, compared side by side.

Capacity
25, 50 and 75 kg, with 100 kg from Ceasefire
Also called
trolley fire extinguisher, wheeled fire extinguisher, 50 kg DCP trolley, mobile fire extinguisher
Used for
Large factories, fuel and chemical stores
Brands
Ceasefire, Kanex, Minimax, Balaji Fire Safety
Supplied by
Fire Protection System, Bhopal (authorised distributor for Ceasefire, Kanex and Minimax; dealer for Balaji Fire Safety), across Madhya Pradesh
Price
On request: WhatsApp or call +91 92440 89060

ABC trolley fire extinguishers compared: all 20 models

Figures as each maker publishes them. Fire ratings are to IS 15683, or to EN 3 or UL where the model carries that approval: a higher number means a larger test fire put out, A for wood, paper and cloth, B for flammable liquids.

ModelCapacityPowderPressureBodyFire ratingDischarge timeThrowHeightFull weightProduct code
Ceasefire Wheeled MAP 50 and MAP 90 Cartridge Type25 kgMAP 90 or MAP 50CartridgeMild steel20A 233B >6 m990 mm66.00 to 70.00 kgCF-001169, CF-000019
Ceasefire Wheeled MAP 50 and MAP 90 Cartridge Type50 kgMAP 90 or MAP 50CartridgeMild steel20A 233B >6 m1200 mm117.00 to 120.00 kgCF-001170, CF-000020
Ceasefire Wheeled MAP 50 and MAP 90 Cartridge Type75 kgMAP 90 or MAP 50CartridgeMild steel20A 233B >6 m1200 mm151.00 to 155.00 kgCF-001192, CF-000021
Ceasefire Wheeled MAP 50 and MAP 90 Stored Pressure25 kgMAP 90 or MAP 50Stored pressureMild steel20A 233B  990 mm59.00 to 63.00 kgCF-001167, CF-000650
Ceasefire Wheeled MAP 50 and MAP 90 Stored Pressure50 kgMAP 90 or MAP 50Stored pressureMild steel20A 233B  1200 mm107.00 to 110.00 kgCF-001168, CF-000651
Ceasefire Wheeled MAP 50 and MAP 90 Stored Pressure75 kgMAP 90 or MAP 50Stored pressureMild steel20A 233B  1200 mm140.00 to 144.00 kgCF-001191, CF-000652
Ceasefire EN Approved Wheeled MAP 50 (EN 1866)25 kgMAP 50 Mild steelA IVB 6 m990 mm62.00 to 64.00 kgCF-000808
Ceasefire EN Approved Wheeled MAP 50 (EN 1866)50 kgMAP 50 Mild steelA IVB 8 m1200 mm110.00 to 113.00 kgCF-000809
Ceasefire EN Approved Wheeled MAP 50 (EN 1866)100 kgMAP 50 Mild steelA IVB 10 m1495 mm178.5 kgCF-000810
Kanex Trolley Mounted MAP 90 (25 to 75 kg)25 kgMAP 90Cartridge 20A 233B32 sec6 m980 mm84 kgKFDRQ-25-90%, KFDRQ-25-UL 90%
Kanex Trolley Mounted MAP 90 (25 to 75 kg)50 kgMAP 90Cartridge 20A 233B40 sec7.5 m1020 mm120 kgKFDRQ-50-90%, KFDRQ-50-UL 90%
Kanex Trolley Mounted MAP 90 (25 to 75 kg)75 kgMAP 90Cartridge 20A 233B51 sec8 m1030 mm150 kgKFDRQ-75-90%, KFDRQ-75-UL 90%
Kanex Trolley Mounted MAP 50 (25 to 75 kg)25 kgMAP 50Cartridge 20A 233B32 sec6 m980 mm84 kgKFDRQ-25-50%
Kanex Trolley Mounted MAP 50 (25 to 75 kg)50 kgMAP 50Cartridge 20A 233B40 sec7.5 m1020 mm120 kgKFDRQ-50-50%
Kanex Trolley Mounted MAP 50 (25 to 75 kg)75 kgMAP 50Cartridge 20A 233B51 sec8 m1030 mm150 kgKFDRQ-75-50%
Minimax Mobile MAP 50 or MAP 90 (25 to 75 kg)25 kgMAP 90 or MAP 50Cartridge 20A 233B30 sec6 m   
Minimax Mobile MAP 50 or MAP 90 (25 to 75 kg)50 kgMAP 90 or MAP 50Cartridge 20A 233B45 sec8 m   
Minimax Mobile MAP 50 or MAP 90 (25 to 75 kg)75 kgMAP 90 or MAP 50Cartridge 20A 233B60 sec10 m   
Balaji Fire Safety Trolley Mounted, 25 kg and 50 kg25 kg Stored pressureMild steel1A     
Balaji Fire Safety Trolley Mounted, 25 kg and 50 kg50 kg Stored pressureMild steel      

Where a 25 to 100 kg trolley ABC fire extinguisher is used

Trolley units weigh about 60 to 180 kg when full and are wheeled to the fire by one or two people. Most models here are rated 20A 233B under IS 16018, the Indian standard for wheeled extinguishers, with a throw of about 6 to 10 m, so they can be used from a safer distance.

They come as cartridge units, where a separate CO2 cylinder pressurises the body when used, or as stored pressure units with a gauge. Ceasefire also makes an EN 1866 approved range up to 100 kg.

  • Large factories and warehouses
  • Fuel, oil and chemical stores
  • Transformer, DG and substation yards
  • Loading bays and truck parking
  • Open plant and process areas
  • Large construction sites

How to choose

Pick the size by the risk and the space: a 25 kg trolley is easier to move through doors and aisles, while 50 and 75 kg units throw further and run longer, about 40 to 60 seconds on the Kanex and Minimax units against about 30 seconds at 25 kg.

Cartridge trolleys can be refilled on site after use; stored pressure trolleys show their charge on a gauge. For fuel and solvent stores, ask us whether foam or CO2 trolleys should sit beside the ABC units.

The 7 models

Frequently asked questions

Who needs a trolley fire extinguisher?
Sites with large or fast growing fire risks: big factories and warehouses, fuel, oil and chemical stores, transformer and generator yards. The Fire NOC conditions for such sites often name trolley units; we check the requirement on a free site visit.
What is the price of a 25 to 100 kg trolley ABC fire extinguisher in Bhopal?
It depends on the brand, the powder grade (MAP 50 or MAP 90), stored pressure or cartridge operation, the body and the quantity, and makers change their price lists often, so we quote each order instead of listing prices. Send the size, the brand if you have one in mind, and the quantity on WhatsApp at +91 92440 89060 and we will reply with the current price. Every supply is billed on a GST invoice.
Does a 25 to 100 kg trolley ABC fire extinguisher need refilling?
Yes. It must be refilled after every use, even a short burst, and checked regularly: the seal should be intact, the service label in date and, on stored pressure units, the gauge needle in the green band. We refill and pressure test ABC extinguishers of every brand in Bhopal, see fire extinguisher refilling.
How many 25 to 100 kg trolley fire extinguishers does my building need?
That depends on the floor area, the kind of fire risk and the rules that apply to the building: IS 2190, the National Building Code and, for a Fire NOC, the MP Fire Department. Our engineers work it out on a free site visit in Bhopal and tell you the number, size and type for each floor.

Need a Fire NOC or renewal in Madhya Pradesh?

We handle your complete Fire NOC application and renewal: documentation, liaison with the MP Fire Department and compliance support.

Talk to our NOC team
Call +91 92440 89060Send a text messageEmail usWhatsApp us