Ceasefire Conventional Fire Alarm Control Panel, 2 to 32 Zones
Ceasefire logoAuthorised distributor for Ceasefire

Ceasefire Conventional Fire Alarm Control Panel, 2 to 32 Zones

Conventional2 to 32 zonesEN 54-2Networkable1 year warranty

Conventional fire alarm panels in 2, 4, 8, 12, 16, 24 and 32 zone sizes, approved to EN 54-2 and 4. The 8 zone and larger panels can be networked, up to 8 control panels, and work with repeater or remote display units.

  • Twin Wire zone option and false alarm management modes
  • One man walk test for easy servicing
  • 2 and 4 zone panels with 2 sounder circuits and a 1.25 A switch mode power supply
  • 8 and 12 zone panels use plug-in zone cards; 16 to 32 zone panels have 4 sounder circuits
  • Programmable relays and outputs on the 8 zone and larger panels
  • 1 year warranty

Standards and approvals: EN54-2

Ask price & availability

Download the official Ceasefire catalogue (PDF, 38.6 MB)

Specifications

Specifications
SpecificationTI-002306Conventiona LTI-002309TI-002310TI-002311TI-002312
TypeConventionalConventionalConventionalConventionalConventional
ModelTI-002306TI-002309TI-002310TI-002311TI-002312
Number of Zones2 Zone12 Zone16 Zone24 Zone32 Zone
Cabinet size308mm W x 260mm H x 80mm D460mm W x 310mm H x 85mm D465mm W x 410mm H x 130mm D465mm W x 410mm H x 130mm D465mm W x 410mm H x 130mm D
Battery capacity2 x 3.2Ah 12v SLAMinimum: 2 x 3.2Ah 12v SLA, Maximum: 2 x 7Ah 12v SLAMinimum: 2 x 7Ah 12v SLA, Maximum: 2 x 18Ah 12v SLAMinimum: 2 x 7Ah 12v SLA, Maximum: 2 x 18Ah 12v SLAMinimum: 2 x 7Ah 12v SLA, Maximum: 2 x 18Ah 12v SLA
Sounder circuits222444
Power Supply1.25 amp switch mode1.25 amp switch mode
Standard Zone Card4 x conventional/Twin Wire fire zones4 x conventional/Twin Wire fire zones
High Specification Zone Card4 x conventional/Twin Wire fire zones, 2 x sounder circuits, 2 x switched negative outputs, 1 x aux relay4 x conventional/Twin Wire fire zones, 2 x sounder circuits, 2 x switched negative outputs, 1 x aux relay