Ravel 2 Zone Agent Release Panel
A microprocessor based 2 zone panel that detects a fire and releases a gaseous agent, with main and standby cylinder output and several release options.

Dealer for RavelA painted die cast dual action pull station with a lift and pull action and a break glass cover, in green or yellow for agent release systems.
| Specification | RE-716P1TLP(G) | RE-716P1TLP(Y) |
|---|---|---|
| Construction Material | Painted Die Cast housing. | 14 Ga plated steel black plate. | Corrosion inhibited surface. | Terminal block ( 4 position). | Single gang mounting. | 10A ,120V AC snap action switch(SPST). | Painted Die Cast housing. | 14 Ga plated steel black plate. | Corrosion inhibited surface. | Terminal block ( 4 position). | Single gang mounting. | 10A ,120V AC snap action switch(SPST). |
| Electrical Switch | 10A@120VAC | 10A@120VAC |
| Weight | 15.5 oz/ 420 grams | 15.5 oz/ 420 grams |
| Width | 3.200 in | 3.200 in |
| Length | 4.750 in | 4.750 in |
| Depth | 0.875 in | 0.875 in |
Specifications as published by Ravel. Please confirm the exact model with us before ordering.
A microprocessor based 2 zone panel that detects a fire and releases a gaseous agent, with main and standby cylinder output and several release options.
A microprocessor based 4 zone agent release panel with two release circuits and solenoid coil monitoring, which Ravel states is UL listed.
A 4 zone agent release panel with separate LED indication for each release circuit, which Ravel states complies with UL 864 (10th edition) and NFPA 72.
A repeater panel that shows all the parameters of the RE-120GR or RE-25AR agent release panel at a second location.
An RS485 driver module for the RE-25AR agent release panel, allowing up to 32 transceivers on the serial bus.
A converter that changes the RE-25AR panel's Ravel protocol to Modbus, for linking to SCADA, PLC or BMS systems.
Conventional control panel for gas suppression, with 3 detection zones and 1 extinguishing zone that can drive solenoid or Metron actuators. A large LCD countdown timer shows the time to release.
Abort switch for extinguishing systems, compatible with the Rapid-Sense control panel and complying with BS 7273-1 requirements.
A compact XC360 series panel for one extinguishing sector, handling detection, evaluation and alarm for up to 126 addressable devices from the Cerberus FIT and Cerberus PRO ranges over C-NET.
The XC360 series single-sector panel for Sinteso peripherals over FDnet, with detection and alarm for up to 126 addressable devices on one loop.
Microprocessor based panel that controls a gas flooding suppression system, with single or cross zone logic, a pre discharge warning and a 24 VDC gas release output. It includes programmable countdowns, manual abort and false release protection.