Ravel 2 Zone Agent Release Panel
A microprocessor based 2 zone panel that detects a fire and releases a gaseous agent, with main and standby cylinder output and several release options.
Dealer for RavelA converter that changes the RE-25AR panel's Ravel protocol to Modbus, for linking to SCADA, PLC or BMS systems.
| Specification | RE- 25MB |
|---|---|
| Operating Voltage | 24 VDC |
| Relative Humidity | 93 ± 2% RH (non-condensing) at 32 ±2° C/96 ±3° F. |
| Standby current | 0.1 Amps (max). |
| Enclosure | Epoxy Powder coated |
| Communication Interface | RS485 / RS232 |
| IP Rating | IP50 |
| Size | (120L X 110H X 60D) mm. |
| Cable Entry | 3 X Ø 19mm Knockout in top of the cabinet. |
| Weight | 0.5 Kgs. |
Specifications as published by Ravel. Please confirm the exact model with us before ordering.
A microprocessor based 2 zone panel that detects a fire and releases a gaseous agent, with main and standby cylinder output and several release options.
A microprocessor based 4 zone agent release panel with two release circuits and solenoid coil monitoring, which Ravel states is UL listed.
A 4 zone agent release panel with separate LED indication for each release circuit, which Ravel states complies with UL 864 (10th edition) and NFPA 72.
A repeater panel that shows all the parameters of the RE-120GR or RE-25AR agent release panel at a second location.
An RS485 driver module for the RE-25AR agent release panel, allowing up to 32 transceivers on the serial bus.
Plastic call points for agent release systems: green for manual emergency release and yellow for abort.
Conventional control panel for gas suppression, with 3 detection zones and 1 extinguishing zone that can drive solenoid or Metron actuators. A large LCD countdown timer shows the time to release.
Abort switch for extinguishing systems, compatible with the Rapid-Sense control panel and complying with BS 7273-1 requirements.
A compact XC360 series panel for one extinguishing sector, handling detection, evaluation and alarm for up to 126 addressable devices from the Cerberus FIT and Cerberus PRO ranges over C-NET.
The XC360 series single-sector panel for Sinteso peripherals over FDnet, with detection and alarm for up to 126 addressable devices on one loop.
Microprocessor based panel that controls a gas flooding suppression system, with single or cross zone logic, a pre discharge warning and a 24 VDC gas release output. It includes programmable countdowns, manual abort and false release protection.
Try "landing valve", "Apollo call point", "9 kg ABC" or a model code.
No products yet. Tap "Add to quote" on any product, then send the whole list to us in one WhatsApp message.