Ravel 2 Zone Agent Release Panel
A microprocessor based 2 zone panel that detects a fire and releases a gaseous agent, with main and standby cylinder output and several release options.
Dealer for RavelA 4 zone agent release panel with separate LED indication for each release circuit, which Ravel states complies with UL 864 (10th edition) and NFPA 72.
Standards and approvals: UL 864, UL -864, NFPA -72
| Specification | RE-26GR |
|---|---|
| Primary Power | 220VAC + 10%, 50 Hz, 2.5Amps, 100W |
| Standby Power | 24VDC (2 No’s of 12 V, 12Ah sealed lead acid battery). |
| Operating Temperature | 0 to 49° C / 32 to 120° F. |
| Relative Humidity | 93 ± 2% RH (non-condensing) at 32 ± 2° C / 90 ± 3° F |
| Storage Temperature | 0 to 60° C |
| Quiescent Current | 120 mA. |
| Charging voltage | 28 V, ± 2% nominal |
| Charging current | 800mA (max) |
| Total NAC Current | 3A (max) |
| NAC 1 & NAC 2 current | 2A per circuit (max) |
| Line drop | 1.8V |
| EOL resistor | 3K9, ½ watt |
| Total RAC Current | 3A (max) |
| RAC 1 & RAC 2 current | 2A per circuit (max) |
| Voltage | 24VDC regulated |
| Current | 300mA (max) |
| Type | Form C |
| Relay contact rating | 0.5A @ 125 VAC |
| Power factor | 1.0 |
| Alarm current | 15 to 30 mA |
| Loop resistance | 100 Ω (max) |
| EOL Resistor | 3K9, ½ watt |
| No. of inputs | 4 No’s |
| Manual release switch | 3 (max) |
| Dimension | 494 W x 380 H x 104 D in mm |
| Cable Entry | 11 x ø 22.5 mm; Knockouts on top of the cabinet 11 x ø 19 mm |
| Construction | 18 Guage CRCA sheet with powder coated finish |
| IP rating | IP 50 |
Specifications as published by Ravel. Please confirm the exact model with us before ordering.
A microprocessor based 2 zone panel that detects a fire and releases a gaseous agent, with main and standby cylinder output and several release options.
A microprocessor based 4 zone agent release panel with two release circuits and solenoid coil monitoring, which Ravel states is UL listed.
A repeater panel that shows all the parameters of the RE-120GR or RE-25AR agent release panel at a second location.
An RS485 driver module for the RE-25AR agent release panel, allowing up to 32 transceivers on the serial bus.
A converter that changes the RE-25AR panel's Ravel protocol to Modbus, for linking to SCADA, PLC or BMS systems.
Plastic call points for agent release systems: green for manual emergency release and yellow for abort.
Conventional control panel for gas suppression, with 3 detection zones and 1 extinguishing zone that can drive solenoid or Metron actuators. A large LCD countdown timer shows the time to release.
Abort switch for extinguishing systems, compatible with the Rapid-Sense control panel and complying with BS 7273-1 requirements.
A compact XC360 series panel for one extinguishing sector, handling detection, evaluation and alarm for up to 126 addressable devices from the Cerberus FIT and Cerberus PRO ranges over C-NET.
The XC360 series single-sector panel for Sinteso peripherals over FDnet, with detection and alarm for up to 126 addressable devices on one loop.
Microprocessor based panel that controls a gas flooding suppression system, with single or cross zone logic, a pre discharge warning and a 24 VDC gas release output. It includes programmable countdowns, manual abort and false release protection.
Try "landing valve", "Apollo call point", "9 kg ABC" or a model code.
No products yet. Tap "Add to quote" on any product, then send the whole list to us in one WhatsApp message.