Siemens Aspirating Smoke Detectors (ASD) in Bhopal

Fire Protection System (FPS), a Siemens dealer in Bhopal, supplies Siemens Cerberus PRO aspirating smoke detectors: the FDA221 and FDA241 ASD and the FDA222, FDA242, FDA261 and FDA262 ASD+ models, covering rooms from 500 m² up to 6700 m². FPS supplies, installs and maintains them across Madhya Pradesh.

Where to use Aspirating Smoke Detection

  • Small business-critical rooms up to 500 m² (FDA221) or 800 m² (FDA241)
  • Business-critical rooms where very early warning of smoke is wanted
  • Larger rooms up to 1600 m² (FDA222) or 3000 m² (FDA242) with one detection chamber
  • Large areas needing two independent aspiration systems in one unit (FDA261, FDA262)
  • Rooms up to 6700 m² (FDA262)
  • Sites on a Siemens FDnet or C-NET addressable loop
  • Sites that want commissioning and maintenance through the ASD Connect app (ASD+ models)
  • Systems linked to the cloud through a Siemens fire panel with gateway (ASD+ models)

Siemens Aspirating Smoke Detection models

How to choose

An aspirating smoke detector (ASD) does not wait for smoke to reach it. An aspirator draws air continuously through small sampling holes in a pipe network into a detection chamber, where light scattering picks up very small amounts of smoke. This gives very early warning in rooms where an early alarm matters.

Start with the area. The FDA221 covers small business-critical rooms up to 500 m² and the FDA241 up to 800 m²; both use dual wavelength (blue and infrared) detection and can talk directly on an FDnet or C-NET loop with the optional FDCC221S communication interface, so no separate relay wiring is needed. The ASD+ models cover more: FDA222 up to 1600 m² (800 m² at Class A), FDA242 up to 3000 m² (1200 m² at Class A), the two-chamber FDA261 up to 3600 m² (2000 m² at Class A) and the FDA262 up to 6700 m² (3000 m² at Class A). The smaller Class A figures are the areas Siemens gives for Class A sensitivity.

The ASD+ models add the ASD Connect app for wireless commissioning and maintenance, cloud data transfer when connected to a Siemens fire panel with gateway, and a modular design in which the detection chamber and aspirator can be replaced. Siemens lists VdS for all six models, UKCA for the FDA221 and FDA241, and AFNOR for the FDA222 and FDA261.

The pipe network has to be planned for each room. FPS supplies, installs and maintains Siemens aspirating detectors in Bhopal and across Madhya Pradesh, and confirms the right model and part numbers with you before ordering.

Frequently asked questions

What is an aspirating smoke detector?
It pulls air from the protected room through sampling holes in a pipe network and checks it in a detection chamber. This lets it find very small amounts of smoke early.
Which Siemens ASD covers the largest area?
The two-chamber FDA262 ASD+ covers rooms up to 6700 m², or 3000 m² at Class A sensitivity, according to Siemens.
What is the difference between ASD and ASD+?
The FDA221 and FDA241 ASD cover up to 500 m² and 800 m². The newer ASD+ models (FDA222, FDA242, FDA261, FDA262) cover larger rooms and add the ASD Connect app, cloud connection through a Siemens panel with gateway and replaceable modules.
Can a Siemens ASD connect to an addressable loop?
Yes. The FDA221 and FDA241 can communicate directly on FDnet or C-NET loops with the optional FDCC221S interface, and all six models list FDnet/C-NET as their protocol.
Does FPS install Siemens aspirating systems in Bhopal?
Yes. FPS is a Siemens dealer and supplies, installs and maintains Siemens aspirating smoke detectors in Bhopal and across Madhya Pradesh. Prices are on request: call or WhatsApp +91 92440 89060.