Siemens FDCIO221 Cerberus PRO Input/Output Module, 1 Input and 1 Output
An addressable module with one monitored input for a potential-free contact and one output for decentralised control of fire doors, ventilation and air conditioning.
Fire Protection System (FPS), a Siemens dealer in Bhopal, supplies Siemens addressable input, output and zone modules, line separators, the Ex line adapter and fire control panel cards (loop extension, line card, network module, I/O card) for Cerberus PRO, Sinteso and Cerberus FIT systems. FPS installs, programs and maintains them across Madhya Pradesh.
An addressable module with one monitored input for a potential-free contact and one output for decentralised control of fire doors, ventilation and air conditioning.
An addressable module with 4 independent monitored inputs and 4 potential-free relay outputs rated AC 250 V / 4 A for fire control installations.
A transponder with 2 configurable inputs/outputs that connects collective detector lines and gives monitored control of dampers, door magnets, alarm devices and extinguishing activation devices.
An addressable module with 4 inputs and 4 relay outputs for connecting the VdS interface of extinguishing activating devices.
An addressable module with one monitored input for a potential-free contact, for technical states or alarms such as a sprinkler alarm.
An addressable module with 4 independent monitored inputs for potential-free contacts, for technical states or alarms.
A zone module that connects one collective or conventional detector line to C-NET, with the detector line powered from an external DC 24 V supply.
An electronic switch on the FDnet or C-NET line that separates a short-circuited section, used where several stub lines branch off at one point.
A module with 9 line separators for several stub lines branching off at one point, which can also connect to 2 separate loops.
A line adapter that electrically isolates Ex and non-Ex lines, so FDnet-Ex and C-NET-Ex devices can run in potentially explosive areas.
A plug-on board that doubles the connectable loops of an integrated panel line from 2 to 4, without changing the number of addresses per station.
An additional line card for the card cage of modular fire control panels, adding FDnet or C-NET lines for 4 loops or 8 stub lines.
A network module that links several fire control panels in an FCnet or C-WEB cluster, plugged into the back of the operating unit.
An additional card with programmable inputs and outputs that expands the integrated I/O of modular fire control panels.
The Cerberus FIT single input module on C-NET, for one potential-free contact reporting a technical state or an alarm.
The Cerberus FIT input/output module on C-NET, with one monitored input and one output for controlling fire doors, ventilation and air conditioning.
Input and output modules connect things that are not detectors to the addressable loop. An input reads a potential-free contact, for example a sprinkler alarm or a door status, and the line to it is monitored for open circuit and short circuit with end resistors. An output switches a relay to control fire doors, ventilation or air conditioning. Each input can be set from the panel as a status or alarm message. Pick by the number of points: the FDCI221 has 1 input and the FDCI222 has 4; the FDCIO221 has 1 input and 1 output (relay AC 22 V, 2 A or monitored DC 30 V, 2 A), and the FDCIO222 has 4 inputs and 4 relay outputs rated AC 250 V / 4 A. The Cerberus FIT FDCI361 and FDCIO361 are the C-NET versions of the single input and input/output modules.
Some modules have special jobs. The FDCIO223 transponder connects collective (conventional) detector lines, including lines with a Zener barrier for explosion-hazard areas, and gives monitored control of smoke dampers, door magnets and extinguishing activation devices through 2 configurable inputs/outputs. The FDCIO224 provides the VdS interface for extinguishing activating devices. The FDCI723 zone module puts one conventional detector line (110 series, DS11, SynoLINE 300/600) onto C-NET with an external DC 24 V supply.
Line separators keep a short circuit from taking down the whole line: the FDCL221 isolates the faulty section by opening the negative conductor, so the healthy side keeps working, and the FDCL221-M packs 9 separators in one module for several stub lines or 2 separate loops. The FDCL221-Ex line adapter electrically isolates Ex and non-Ex lines for FDnet-Ex and C-NET-Ex devices.
Panel cards expand the control panel itself: the FCI2003-A1 loop extension doubles the connectable loops from 2 to 4 on an integrated line, the FCL2001-A1 line card adds 4 loops or 8 stub lines in modular panels, the FCI2008-A1 adds programmable inputs and outputs, and the FN2001-A1 SAFEDLINK module networks up to 32 panels. FPS confirms the module and card part numbers against your panel before ordering.