ISO 9001:2015 Certified · MSME Registered · Military Engineering Services Registered
Fire Protection System logoFIRE PROTECTION SYSTEMTMFire safety contractors, dealers & distributors · Bhopal, M.P.
EXCELLENCE IN FIRE EXTINGUISHER, FIRE HYDRANT, FIRE ALARM & FIRE SUPPRESSION SYSTEMS
Supplier for Tyco

Tyco Deluge and Preaction Valves in Bhopal

Fire Protection System (FPS) supplies Tyco deluge and preaction valves and their trim in Bhopal: DV-5A diaphragm valves for each type of actuation, SV-1 deluge valves, Red-E Cabinet valve packages, EN 12845 preaction valves, dry pilot actuators, manual stations, releases, drains and solenoid valves.

Where to use Deluge and Preaction Valves

  • Industrial processing plants and outdoor installations, including corrosive atmospheres (epoxy coated DV-5A)
  • Computer rooms
  • Storage areas for valuable artefacts
  • Libraries and archives
  • Refrigerated areas that need protection against accidental flooding of the pipes (double interlock preaction)
  • Unheated warehouses, parking garages, attic spaces and loading docks (DPV-1 Preaction Type B)
  • Valve rooms with little floor space (Red-E Cabinet packages)
  • Systems where the valve must be opened and closed from a remote location (remote-resetting DV-5A)
  • Projects designed to EN 12845 (Preaction Type A and Type B valves)

Tyco Deluge and Preaction Valves models

Tyco

Tyco Model SV-1 Deluge Valve, Diaphragm Type, Electric Actuation, DN80 to DN200 (TFP1360)

Deluge valveElectric actuationDN80 to DN200

Sizes: DN80 to DN200

A diaphragm type automatic water control valve for deluge systems, made for vertical installation and released electrically, which also actuates fire alarms when trimmed.

  • Approvals: UL and cUL Listed Deluge Valve: The SV-1 Deluge Valves are for vertical installation only, and are rated for use at a maximum service pressure of 12 bar (175 psi).
Tyco

Tyco Model SV-1 Deluge Valve, Diaphragm Type, Wet Pilot Actuation, DN80 to DN200 (TFP1361)

Deluge valveWet pilot actuationDN80 to DN200

Sizes: DN80 to DN200

A diaphragm type automatic water control valve for deluge systems, made for vertical installation and released by a wet pilot line, which also actuates fire alarms when trimmed.

  • Approvals: UL and C-UL Listed
Tyco

Tyco Model ASV-1 Automatic Shut-Off Valve, DV-5 Trim Component (TFP1384)

Trim componentFor DV-5Prevents unwanted reset

A trim component for the DV-5 deluge valve, fitted in the diaphragm chamber supply connections, that stops the valve resetting by accident after it has first operated.

  • Approvals (As a valve trim component for the DV-5 Deluge Valve): UL and C-UL Listed FM Approved
  • Maximum Working Water Pressure: 250 psi (17,2 bar)
Tyco

Tyco Model FSV-1 Fail-Safe Valve, DV-5 Trim Component (TFP1386)

Trim componentFor DV-5Prevents unwanted reset

A trim component used in certain DV-5 deluge valve trim arrangements, fitted next to the releasing devices, that stops the valve resetting by accident after it has first operated.

  • Approvals: UL and C-UL Listed FM Approved (As a valve trim component for the DV-5 Deluge Valve)
  • Maximum Working Water Pressure: 250 psi (17,2 bar)

How to choose

A deluge valve holds back the water from a system of open sprinklers or nozzles; when the detection system operates, the valve opens and all of them discharge together. A preaction valve does the same job on a system of closed sprinklers: detection opens the valve and fills the pipes, but water comes out only where a sprinkler has opened in the heat of the fire. Most Tyco valves on this page are the DV-5A, a diaphragm type automatic water control valve in DN40 to DN200, epoxy coated inside and out. It is reset from outside by re-pressurising the diaphragm chamber, with no cover to open, and when trimmed it also raises the fire alarm.

Next, choose how the valve is released. Wet pilot and dry pilot versions are opened by pilot lines, filled with water or with air, that carry heat sensitive releases such as pilot sprinklers or FTR-1 fixed temperature releases; dry lines also need a DP-1 or DP-2 dry pilot actuator. Electric versions are opened by a releasing panel and solenoid valve. Remote-resetting versions can be opened and closed under full flow from a remote location, and the pressure-reducing version also holds a preset outlet pressure. The SV-1 is a separate diaphragm deluge valve, DN80 to DN200, for vertical installation only and rated 12 bar.

For preaction, single interlock means one event, the detection system operating, opens the valve. It suits computer rooms, archives and libraries where a damaged sprinkler or pipe could cause serious water damage, and a low air pressure in the pipes is monitored to reveal leaks. Double interlock means two independent events are needed, detection and a sprinkler opening, for areas such as refrigerated spaces where accidental flooding of the pipes must be avoided; Tyco offers electric/pneumatic and electric/electric versions. TFP1485 (DV-5A Preaction Type A) and TFP1486 (DPV-1 Preaction Type B) are designed to EN 12845.

Red-E Cabinet packages put a DV-5A riser, control valve and switches, and in two of the three versions a control panel with back-up batteries, into one pre-wired, free-standing cabinet. Approvals differ by data sheet and trim, so FPS checks the TFP number for each project before supplying and installing Tyco deluge and preaction valves in Bhopal and across Madhya Pradesh.

Frequently asked questions

What is the difference between a deluge valve and a preaction valve?
Both hold water back until a detection system opens them. In a deluge system the sprinklers or nozzles are open, so all of them discharge at once; in a preaction system the sprinklers are closed, so water fills the pipes and comes out only where a sprinkler has opened.
What do single interlock and double interlock mean?
In a single interlock preaction system, operation of the detection system alone opens the valve. In a double interlock system two independent events are needed, the detection system operating and an automatic sprinkler opening, which guards against accidental flooding of the pipes.
How is a Tyco DV-5A valve reset?
From the outside: re-pressurising the diaphragm chamber resets the valve, so there is no handhole cover to open and no clapper or latch to reposition by hand. Remote-resetting versions can also be closed from a remote location.
What sizes do Tyco deluge valves come in?
The DV-5A data sheets cover DN40 to DN200 (1-1/2 to 8 inch), except the remote-resetting pressure-reducing version, which covers DN80 to DN200. The SV-1 deluge valve also comes in DN80 to DN200.
Which Tyco valves are made for EN 12845 projects?
The DV-5A for Preaction Type A systems (TFP1485) and the DPV-1 Preaction Type B valve (TFP1486), both of which Tyco lists as VdS Approved. For the DPV-1 Type B, Tyco states the approval covers DN100 and DN150, with DN65 and DN80 available on request without approval.
Does FPS supply and install Tyco deluge and preaction valves?
Yes. FPS supplies, installs and maintains Tyco sprinkler system valves in Bhopal and across Madhya Pradesh. Prices are on request: call or WhatsApp +91 92440 89060.

More Tyco products

Call +91 92440 89060Send a text messageEmail usWhatsApp us