ISO 9001:2015 Certified · MSME Registered · Military Engineering Services Registered
Fire Protection System logoFIRE PROTECTION SYSTEMTMFire safety contractors, dealers & distributors · Bhopal, M.P.
EXCELLENCE IN FIRE EXTINGUISHER, FIRE HYDRANT, FIRE ALARM & FIRE SUPPRESSION SYSTEMS
Supplier for Tyco

Tyco Residential Sprinklers in Bhopal

Fire Protection System (FPS) supplies Tyco Series LFII residential sprinklers in Bhopal: pendent, sidewall, concealed and dry-type heads designed for homes, apartments, dormitories and hotels built to NFPA 13D, 13R or 13. FPS installs and maintains them across Madhya Pradesh.

Where to use Residential Sprinklers

  • Homes, including one- and two-family dwellings (NFPA 13D)
  • Apartment buildings and other residential buildings up to four storeys (NFPA 13R)
  • Residential floors of mixed-use buildings (NFPA 13)
  • Dormitories
  • Hotels
  • Small rooms up to 14 ft by 14 ft, with the K3.0 pendent
  • Homes with plastic sprinkler pipe, with the polymeric concealed pendents
  • Unheated parts of a home, with the dry pipe listed or dry-type LFII models

Tyco Residential Sprinklers models

How to choose

Residential sprinklers are made for dwellings rather than shops or factories. Every model here is from the Tyco Series LFII, which Tyco designs for homes, apartments, dormitories and hotels (the polymeric K3.0 for homes), with heat sensitivity and water spread aimed at helping control a home fire and giving occupants a better chance to escape. They are used in systems built to NFPA 13D (one- and two-family dwellings and mobile homes), NFPA 13R (residential buildings up to and including four storeys) or NFPA 13 (the residential parts of any building). These are US National Fire Protection Association standards.

Choose the K-factor with your designer. The K3.0 pendent is sized for small rooms up to 14 ft by 14 ft, to avoid over-discharging, which Tyco says lets the required flow come through smaller pipes from a smaller water supply. The range also comes in K4.2, K4.4, K4.9 and K5.8, and the K5.6 sidewall, the K5.8 sidewall in TFP417 and the K6.9 models are NFPA 13 optimized, meant for NFPA 13 designs that need higher flows.

Then choose the style. Pendent and recessed pendent heads hang from the ceiling; horizontal sidewall heads fit on a wall; concealed pendents hide behind a flat or domed cover plate, and there is a concealed sidewall too. The polymeric K3.0 and K4.9 concealed pendents must be fitted to plastic sprinkler pipe and fittings, and carry NSF/ANSI 61 certification (a US standard for drinking water system components) and NSF/ANSI 372 lead-free certification. Most concealed models pair a 68°C sprinkler with a 59°C cover plate, and Tyco limits several of them to ceilings no hotter than 38°C.

Most LFII models are for wet pipe systems only. The TFP400 pendent, TFP410 sidewall and TFP450 domed plate concealed pendent carry a UL listing for dry pipe systems as well, and the dry-type TFP460 and TFP461 are for pipes running into unheated areas. FPS supplies, installs and maintains Tyco residential sprinklers in Bhopal and across MP and can help pick the right data sheet for your building.

Frequently asked questions

What is a residential sprinkler?
It is a sprinkler made for homes, apartments, dormitories and hotels, used in systems built to NFPA 13D, 13R or the residential parts of NFPA 13. Tyco designs the LFII series to help control a home fire and give occupants a better chance to escape.
What do NFPA 13D and NFPA 13R mean?
They are US National Fire Protection Association standards for home sprinkler systems. NFPA 13D covers one- and two-family dwellings and mobile homes, and NFPA 13R covers residential buildings up to and including four storeys.
Can Tyco residential sprinklers be used on a dry pipe system?
Most LFII models are wet pipe only. The TFP400 pendent, TFP410 sidewall and TFP450 domed plate concealed pendent are UL Listed for dry pipe systems too, and Tyco states the number of design sprinklers need not be increased over a wet pipe design.
Which Tyco residential sprinkler suits a small room?
The LFII K3.0 pendent (TY1234) is designed for small coverage areas up to 14 ft by 14 ft. A concealed K3.0 version (TY1534) is also available for homes with plastic sprinkler pipe.
Are there hidden sprinklers for homes and hotel rooms?
Yes. The LFII range includes flat plate concealed pendents in K3.0, K4.9 and K5.8, a domed plate concealed pendent, a K6.9 concealed pendent and a K4.2 concealed sidewall.
Does FPS supply and install Tyco residential sprinklers?
Yes. FPS supplies, installs and maintains Tyco residential sprinklers in Bhopal and across Madhya Pradesh. Prices are on request: call or WhatsApp +91 92440 89060.

More Tyco products

Call +91 92440 89060Send a text messageEmail usWhatsApp us