System Sensor M201EA-240 Addressable Mains Switching Output Module
A loop-powered output module from the Series 200 plus range that controls an unsupervised double pole output for 240VAC loads, latching on or off on command from the panel.

Multi-way addressable modules for places where many single modules would otherwise be needed, each point with its own address set on rotary decade switches.
Standards and approvals: CPR
| Specification | CR-6 | SC-6 | CZ-6 | IM-10 |
|---|---|---|---|---|
| Operating Voltage Range | 15 to 32VDC | 15 to 32VDC | 15 to 32VDC | 15 to 32VDC |
| Maximum Wiring Resistance | 40 Ohms | 40 Ohms | 40 Ohms | 40 Ohms |
| Application Temperature Range | -0°C to +50°C | -0°C to +50°C | -0°C to +50°C | -0°C to +50°C |
| Humidity | 10% to 90% relative Humidity (non-condensing) | 10% to 90% relative Humidity (non-condensing) | 10% to 90% relative Humidity (non-condensing) | 10% to 90% relative Humidity (non-condensing) |
| Size | 173mm H x 147mm W x 32mm D | 173mm H x 147mm W x 32mm D | 173mm H x 147mm W x 32mm D | 173mm H x 147mm W x 32mm D |
| Min/Max Wire Gauge for Terminals | 1.0mm2 to 2.0mm2 | 1.0mm2 to 2.0mm2 | 1.0mm2 to 2.0mm2 | 1.0mm2 to 2.0mm2 |
| Maximum Standby Current | 1.49mA (Blinking LED once every 5 seconds) | 2.34mA (Blinking LED once every 5 seconds) | 2.04mA (Blinking LED once every 5 seconds) | 3.50mA (Blinking LED once every 5 seconds) |
| Maximum Alarm Current | 36mA at 32V assuming all six relays have switched once and all six LEDs solid on | 36mA at 32V assuming all six relays have switched once and all six LEDs solid on | 40mA at 32V assuming all six LEDs solid on | 60mA at 32V assuming all ten LEDS solid on |
| Relay current | 30mA/relay pulse 15.6ms duration, pulse under panel control | |||
| Relay Contact Ratings | 3A at 30VDC Resisitive Load | 3A at 30VDC Resisitive Load | ||
| Maximum Supervising Line Resistance | 1000 Ohms | |||
| Maximum Loop Wiring Resistance | 40 Ohms or Max supervising line wiring resistance 25 Ohms | |||
| External Supply Voltage | DC Voltage: 18 to 28V power limited | Ripple Voltage: 0.1V rms maximum. Current: 480mA at 24V (all six zones in alarm) | |||
| Maximum Supervising Line Wiring Resistance | 1000 Ohms | |||
| Maximum Line Voltage | 11.3VDC | |||
| Maximum Line Current | 240µA |
Specifications as published by System Sensor. Please confirm the exact model with us before ordering.
A loop-powered output module from the Series 200 plus range that controls an unsupervised double pole output for 240VAC loads, latching on or off on command from the panel.
Single and multi-way addressable modules on one mechanical platform that can be box, panel or DIN rail mounted, with the address switch and LEDs visible whichever mounting is used.
The M200EA addressable input and output modules, which can be mounted in a common wall box, on a DIN rail or in their dedicated enclosure, with enlarged light pipes for status.
Modules that connect a zone of conventional detectors, or intrinsically safe conventional detectors on the CZR version, to a System Sensor analogue addressable system.
Single input conventional zone modules from the M200EA family, with an end of line capacitor (CZ) or resistor (CZR); the CZR version also accepts intrinsically safe conventional detectors.
A compact addressable input module for normally open contact devices such as security contacts, waterflow switches and call points, small enough to fit inside devices or junction boxes.
An intelligent addressable control module that supervises wiring to devices powered from an external supply, such as horns, strobes or bells, with Class A or Class B supervision.
An addressable relay module giving a dry-contact output to switch auxiliary devices such as fans, dampers and control equipment, using one of 159 module addresses on the SLC loop.
A single channel addressable input module for Morley-IAS intelligent panels. It watches an external device and reports normal, open circuit and alarm states to the panel.
A small monitor module that fits in a single gang junction box directly behind the device it monitors, giving a two-wire initiating circuit for normally open fire alarm and security contacts.
A loop device that monitors single pole, volt-free contact inputs and controls relay output contacts, linking the fire panel to other equipment. It works with XP95, Discovery and CoreProtocol.
An input/output module with two input channels for single pole, volt-free contacts and mains switching relay output contacts.