ISO 9001:2015 Certified · MSME Registered · Military Engineering Services Registered
Fire Protection System logoFIRE PROTECTION SYSTEMTMFire safety contractors, dealers & distributors · Bhopal, M.P.
EXCELLENCE IN FIRE EXTINGUISHER, FIRE HYDRANT, FIRE ALARM & FIRE SUPPRESSION SYSTEMS
Dealer for Ravel

Ravel Addressable Smoke and Heat Detectors in Bhopal

Fire Protection System (FPS), a Ravel dealer in Bhopal, supplies Ravel analogue addressable detectors: photoelectric smoke, heat and combined smoke and heat models for Ravel's multi loop system and for its single loop MonitI system. FPS installs, tests and maintains them across Madhya Pradesh.

Where to use Addressable Detectors

  • Offices and IT buildings
  • Hospitals and nursing homes
  • Hotels and residential towers
  • Shopping malls and multiplexes
  • Schools, colleges and hostels
  • Factories and warehouses
  • Kitchens and plant rooms (heat detectors)
  • Large buildings where the panel must show the exact device in alarm

Ravel Addressable Detectors models

How to choose

An addressable detector has its own address on the panel's loop, so the panel shows exactly which detector is in alarm instead of only the zone. First match the detector to the panel. The RE 317D detectors are for Ravel's multi loop system and are addressed from 1 to 254 with an 8 way DIP switch. The RE-337 detectors are for the single loop MonitI panel and are soft addressed, so no switches need to be set by hand.

Next choose what to sense. A photoelectric smoke detector senses smoke optically and suits most rooms, corridors and offices. A heat detector suits places where smoke or steam is normal, such as kitchens; Ravel's heat and multi sensor models alarm at a fixed 59 °C or when the temperature rises by 11.1 °C per minute. A multi sensor detector has both a smoke sensor and a heat sensor in one head.

All six detectors run on 17 to 28 V DC, are polarity insensitive, have dual LEDs visible through 360° and a low profile housing on a regular 100 mm base, and are rated IP42. Ravel states UL listing for the RE 317D range and EN 54 compliance for the RE-337 range. An isolator base (RE-314BI for RE 317D, RE-374BI for RE-337) keeps a wiring short from affecting the whole loop. FPS supplies, installs and maintains Ravel detectors in Bhopal and across Madhya Pradesh.

Frequently asked questions

What is an addressable detector?
It is a detector with its own address on the fire alarm panel's loop, so the panel shows the exact detector in alarm. Ravel's addressable detectors are analogue addressable.
Which Ravel detector works with which panel?
The RE 317D detectors are for Ravel's multi loop system, and the RE-337 detectors are for the MonitI single loop panel.
How is a Ravel addressable detector given its address?
The RE 317D detectors use an 8 way DIP switch for addresses 1 to 254. The RE-337 detectors are soft addressed by programming.
What is a multi sensor detector?
It combines a photoelectric smoke sensor and a heat sensor in one head. Ravel offers it as the RE317D-SHL for the multi loop system and the RE-337SH for the single loop system.
Are Ravel addressable detectors approved?
Ravel states UL listing for the RE 317D smoke, heat and multi sensor detectors, and EN 54 compliance for the RE-337 detectors.
Does FPS install Ravel addressable detectors in Bhopal?
Yes. FPS is a Ravel dealer and supplies, installs and maintains Ravel addressable detectors in Bhopal and across Madhya Pradesh. Prices are on request: call or WhatsApp +91 92440 89060.