Ravel Addressable Multi Sensor Detector, Smoke and Heat (Multi Loop)
An analogue addressable detector for Ravel's multi loop system that combines photoelectric smoke sensing with a heat sensor.
Fire Protection System (FPS), a Ravel dealer in Bhopal, supplies Ravel analogue addressable detectors: photoelectric smoke, heat and combined smoke and heat models for Ravel's multi loop system and for its single loop MonitI system. FPS installs, tests and maintains them across Madhya Pradesh.
An analogue addressable detector for Ravel's multi loop system that combines photoelectric smoke sensing with a heat sensor.
An analogue addressable photoelectric smoke detector for Ravel's multi loop system, with an insect filter chamber and DIP switch addressing.
An analogue addressable heat detector for Ravel's multi loop system, alarming at a fixed 59 °C or on a fast temperature rise.
An analogue addressable smoke and heat detector for the Ravel MonitI single loop panel, soft addressed by programming.
An analogue addressable photoelectric smoke detector for the Ravel MonitI single loop panel, soft addressed by programming.
An analogue addressable heat detector for the Ravel MonitI single loop panel, alarming at a fixed 59 °C or on a fast temperature rise.
An addressable detector has its own address on the panel's loop, so the panel shows exactly which detector is in alarm instead of only the zone. First match the detector to the panel. The RE 317D detectors are for Ravel's multi loop system and are addressed from 1 to 254 with an 8 way DIP switch. The RE-337 detectors are for the single loop MonitI panel and are soft addressed, so no switches need to be set by hand.
Next choose what to sense. A photoelectric smoke detector senses smoke optically and suits most rooms, corridors and offices. A heat detector suits places where smoke or steam is normal, such as kitchens; Ravel's heat and multi sensor models alarm at a fixed 59 °C or when the temperature rises by 11.1 °C per minute. A multi sensor detector has both a smoke sensor and a heat sensor in one head.
All six detectors run on 17 to 28 V DC, are polarity insensitive, have dual LEDs visible through 360° and a low profile housing on a regular 100 mm base, and are rated IP42. Ravel states UL listing for the RE 317D range and EN 54 compliance for the RE-337 range. An isolator base (RE-314BI for RE 317D, RE-374BI for RE-337) keeps a wiring short from affecting the whole loop. FPS supplies, installs and maintains Ravel detectors in Bhopal and across Madhya Pradesh.
Try "landing valve", "Apollo call point", "9 kg ABC" or a model code.
No products yet. Tap "Add to quote" on any product, then send the whole list to us in one WhatsApp message.