ISO 9001:2015 Certified · MSME Registered · Military Engineering Services Registered
Fire Protection System logoFIRE PROTECTION SYSTEMTMFire safety contractors, dealers & distributors · Bhopal, M.P.
EXCELLENCE IN FIRE EXTINGUISHER, FIRE HYDRANT, FIRE ALARM & FIRE SUPPRESSION SYSTEMS
Dealer for Morley by Honeywell

Morley by Honeywell Fire Detectors in Bhopal

Fire Protection System (FPS), a Morley dealer in Bhopal, supplies Morley-IAS smoke, multi-criteria and heat detectors for the DXc, ZXSe, Morley Max and Morley UL panels, with and without built-in isolators, plus the Morley Lite detectors. FPS installs, tests and maintains them across Madhya Pradesh.

Where to use Addressable Detectors

  • Commercial buildings and office complexes
  • Government offices and banks
  • Malls and stores
  • Factories, manufacturing and industry
  • Hotels, hospitals and clinics
  • Educational institutions
  • Residential buildings and complexes
  • Kitchens and bars, with a heat detector where a smoke detector is unsuitable
  • Air ducts, for the UL smoke and multi-sensor detectors listed for duct air velocities

Morley by Honeywell Addressable Detectors models

How to choose

Start with the panel, because each Morley detector line is listed with a panel range. The HM/PSE/S2, HM/PTSE, HM/RHSE, HM/FHSE, MI-HTSE-S2I-IV and MI-PTIR-S2-IV are listed with the DXc and ZXSe panels; the HM-PSE-AP, HM-PTSE-AP, HM-RHSE-AP and HM-FHSE-AP families with Morley Max; the HM/.../UL/W detectors with the Morley UL range (STX and SMX panels); and the HML detectors with the Morley Lite panel. An addressable detector has its own address on the panel's loop, so the panel shows exactly which detector is in alarm. The Morley Max detectors use the HM Advanced Protocol, which Morley says puts more devices on the loop and gives more control, configurability and device management.

Then choose the sensing type. A photoelectric (optical) smoke detector senses smoke inside its optical chamber. A photo-thermal multi-criteria detector adds a heat sensor to the smoke sensor and judges both together, which Morley uses for better false alarm immunity and faster response to a wide range of fires. Heat detectors suit places where smoke detectors would be unsuitable, such as bars and kitchens. EN 54-5 is the European standard for point heat detectors: Class A1R combines a fixed threshold with rate of rise sensing, and Class A1S is fixed temperature only. The HM/RHSE gives fixed 58°C and rate of rise (10°C per minute) sensing, the HM/FHSE a fixed 58°C response.

Next, decide on isolators. A short-circuit isolator disconnects a shorted section of the loop so the rest of the loop keeps working. In the Morley Max range each detector type comes as a standard model or an isolator model (the -I- part numbers, listed to EN 54-17), and the MI-PSE-S2, MI-RHSE-S2 and MI-FHSE-S2 series have isolator versions marked S2I. The Morley UL detectors are UL listed with the B300-6-IV base, under listing S36216 for smoke and multi-sensor models and S36217 for heat models.

FPS checks the panel range, the room use and the ceiling before choosing detectors, then supplies, installs, tests and maintains Morley-IAS detectors in Bhopal and across Madhya Pradesh.

Frequently asked questions

Which Morley detector works with my panel?
It depends on the range: HM/PSE/S2, HM/PTSE, HM/RHSE and HM/FHSE are listed with DXc and ZXSe panels, the HM-...-AP detectors with Morley Max, the HM/.../UL/W detectors with the Morley UL range and the HML detectors with Morley Lite. Send FPS your panel model and we will confirm the part number.
What is a multi-criteria detector?
It has more than one sensing element in one head and judges them together. The Morley HM/PTSE adds 58°C fixed temperature and rate of rise thermal sensing to a photoelectric smoke sensor, for better false alarm immunity and faster response.
What do Class A1R and A1S mean on a heat detector?
They are EN 54-5 heat detector classes. The Morley HM/RHSE is Class A1R, with fixed 58°C and rate of rise sensing, and the HM/FHSE is Class A1S, a fixed 58°C detector.
What does the I in HM-PSE-I-AP mean?
It marks the isolator version. The -I- detectors in the Morley Max range have a built-in short-circuit isolator and list EN 54-17, so a short on the loop is cut off without stopping the rest of the loop.
Which Morley detector suits a kitchen?
Morley describes the HML/RHSE thermal detector for places such as bars and kitchens, where airborne contamination makes smoke detectors unsuitable. For addressable systems, FPS picks the HM heat detector that matches your panel.
Does FPS supply and install Morley detectors in Bhopal?
Yes. FPS is a Morley dealer and supplies, installs, tests and maintains Morley-IAS detectors in Bhopal and across Madhya Pradesh. Prices are on request: call or WhatsApp +91 92440 89060.

More Morley by Honeywell products

Call +91 92440 89060Send a text messageEmail usWhatsApp us