Morley by Honeywell MI/DMMI Addressable Single Input Monitor Module
A single channel addressable input module for Morley-IAS intelligent panels. It watches an external device and reports normal, open circuit and alarm states to the panel.
Fire Protection System (FPS), a Morley dealer in Bhopal, supplies Morley-IAS addressable monitor, control, relay, zone and isolator modules for the DXc, ZXSe, Morley Max and Morley UL panels. FPS installs, programs, tests and maintains them across Madhya Pradesh.
A single channel addressable input module for Morley-IAS intelligent panels. It watches an external device and reports normal, open circuit and alarm states to the panel.
A small monitor module that fits in a single gang junction box directly behind the device it monitors, giving a two-wire initiating circuit for normally open fire alarm and security contacts.
A loop isolator for Morley-IAS intelligent panels that protects the addressable loop against wire-to-wire short circuits by disconnecting the faulty section.
A single channel addressable output module that provides either a single alarm circuit or a Form C relay, for door holders, air handling unit shut down and similar functions.
An addressable module with two monitored input circuits and one volt-free changeover relay, for reading external devices and controlling an external circuit.
A loop-powered wall mounting output module for switching 240Vac loads, with an unsupervised double pole relay that latches on or off on command from the panel.
A zone module that lets a zone of two-wire non-addressable (conventional) devices communicate with a Morley-EN protocol analogue addressable system.
An addressable dual input module from the newer Morley input/output module platform, listed with the Morley Max panels.
An addressable module with two inputs and one output from the newer Morley input/output module platform, listed with the Morley Max panels.
An addressable module from the newer Morley input/output module platform, listed with the Morley Max panels. The maker's page gives it the same subtitle as the MI-DCMOE and links no datasheet, so FPS confirms its function for your design before supply.
An addressable single output module from the newer Morley input/output module platform, listed with the Morley Max panels.
An addressable control module that switches 24 VDC audible and visual power and provides a circuit for notification appliances such as horns and strobes, activated by panel programming for a selected zone or area.
An addressable relay module that gives a dry contact output for fans, door holders, dampers and control equipment, and can reset four-wire smoke detector power.
A standard-sized monitor module that supervises a Class B circuit of dry contact devices such as four-wire smoke detectors, pull stations and water flow devices. It can also power and monitor two-wire smoke detector circuits.
A miniature monitor module that fits in a single-gang box behind the device it monitors and supervises a Class B circuit of dry contact inputs, powered directly from the two-wire SLC loop.
A standard-sized module that monitors one full zone of compatible two-wire, 24 V conventional smoke detectors on a Class B circuit and reports normal, open or alarm status to the panel.
A fault isolator module that protects the SLC loop against wire-to-wire short circuits, so other devices keep working during a short. It is required for true Style 7 operation.
Modules connect things that are not detectors to the addressable loop. A monitor (input) module watches a contact, such as a water flow switch or a four-wire smoke detector, and reports its status to the panel. A control (output) or relay module switches something on command from the panel, such as door holders, fans, dampers or an air handling unit shut down. A zone module brings a whole circuit of conventional (non-addressable) detectors onto the loop, and an isolator module cuts off a short-circuited section of the loop so the rest keeps working.
For DXc and ZXSe panels, the MI/DMMI single input module, MI-MM3E-S2 mini monitor module, MI/D2ICMO dual input and single output module, MI/DCMO control output module, MI/D240CMO 240V AC output module, MI/DCZRM zone monitor module and MI/DISO loop isolator are listed. The MI/DCMO and MI/DCZRM each use one of the 99 module addresses on a loop. For Morley Max panels, the newer MI-DMM2IE, MI-D2ICMOE, MI-DMMIE and MI-DCMOE modules are listed, but their page links no datasheet.
For the Morley UL range, the HM/DMMI/UL and HM/MM3E/UL monitor modules supervise a Class B initiating device circuit (IDC) of dry contact inputs, the HM/DCZRM/UL monitors a zone of two-wire 24 V smoke detectors, the HM/DCMO/UL switches 24 VDC power to horns and strobes, the HM/D240CMO/UL gives a dry contact rated 3.0 A at 30 VDC, and the HM/DISO/UL isolator allows up to 25 devices between isolators on the SLC (signalling line circuit, the loop).
FPS checks the panel range, the load to be switched and the wiring before choosing a module, then supplies, installs, programs and tests Morley-IAS modules in Bhopal and across Madhya Pradesh.